Changes for page LSS-PRO Electrical

Last modified by Eric Nantel on 2024/07/12 12:50

From version < 37.1 >
edited by Eric Nantel
on 2024/07/12 12:23
To version < 23.1 >
edited by Eric Nantel
on 2023/08/01 12:32
< >
Change comment: Upload new image "LSS-P-S1-Pinout-RJ45.png", version 1.1

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -LSS-PRO Electrical
1 +LSS-P - Electrical
Parent
... ... @@ -1,1 +1,1 @@
1 -ses-pro.lss-pro.WebHome
1 +lynxmotion-smart-servo-pro.WebHome
Hidden
... ... @@ -1,1 +1,1 @@
1 -false
1 +true
Content
... ... @@ -6,6 +6,8 @@
6 6  
7 7  
8 8  
9 +
10 +
9 9  **Page Contents**
10 10  
11 11  {{toc/}}
... ... @@ -17,26 +17,28 @@
17 17  (% style="width:800px" %)
18 18  |(% style="text-align:center; width:350px" %)**Serial Single**|(% style="text-align:center; width:350px" %)**Serial Multiples**
19 19  |(% style="width:350px" %)(((
20 -{{lightbox image="https://wiki.lynxmotion.com/info/wiki/lynxmotion/download/ses-pro/lss-pro/lss-p-electrical/WebHome/LSS-P-Wiring-Single.png" width="400"/}}
22 +{{lightbox image="https://wiki.lynxmotion.com/info/wiki/lynxmotion/download/lynxmotion-smart-servo-pro/lss-p-electrical/WebHome/LSS-P-Wiring-Single.png" width="400"/}}
21 21  )))|(% style="width:350px" %)(((
22 -{{lightbox image="https://wiki.lynxmotion.com/info/wiki/lynxmotion/download/ses-pro/lss-pro/lss-p-electrical/WebHome/LSS-P-Wiring-Dual.png" width="400"/}}
24 +{{lightbox image="https://wiki.lynxmotion.com/info/wiki/lynxmotion/download/lynxmotion-smart-servo-pro/lss-p-electrical/WebHome/LSS-P-Wiring-Dual.png" width="400"/}}
23 23  )))
24 24  
25 25  = Wiring Pinout =
26 26  
27 27  |(% colspan="3" style="width:350px" %)**CAN Bus**
28 -|(% rowspan="4" style="width:350px" %)(((
29 -{{lightbox image="https://wiki.lynxmotion.com/info/wiki/lynxmotion/download/ses-pro/lss-pro/lss-p-electrical/WebHome/LSS-P-S1-Pinout-RJ45.png"/}}
30 -)))|(% style="text-align:left; vertical-align:middle; width:35px" %)[[image:[email protected]]]|(% style="text-align:left; vertical-align:middle" %)(((
31 -**#4: **CAN High (Texas Instruments SN65HVDA1040AQDRQ1)
30 +|(% style="width:350px" %) |(% style="text-align:left; vertical-align:middle; width:35px" %) |(% style="text-align:center; vertical-align:middle" %)**Serial Mode**
31 +|(% rowspan="5" style="width:350px" %)(((
32 +{{lightbox image="https://wiki.lynxmotion.com/info/wiki/lynxmotion/download/lynxmotion-smart-servo-pro/lss-p-electrical/WebHome/LSS-P-S1-Pinout-RJ45.png"/}}
33 +)))|(% style="text-align:left; vertical-align:middle; width:35px" %)[[image:[email protected]]]|(% style="text-align:left; vertical-align:middle" %)(((
34 +**Servo Rx**: In serial mode, this pin should be connected to a 5V TTL serial pin. In RC mode, the pin should be connected to an 5V RC PWM pin
32 32  )))
33 -|(% style="text-align:left; vertical-align:middle" %)[[image:lynxmotion-wiki-attachments.WebHome@SQUARE-Yellow.png]]|(% style="text-align:left; vertical-align:middle" %)(((
34 -**#5: **CAN Low (Texas Instruments SN65HVDA1040AQDRQ1)
36 +|(% style="text-align:left; vertical-align:middle" %)[[image:lynxmotion-wiki-attachments.WebHome@SQUARE-Green.png]]|(% style="text-align:left; vertical-align:middle" %)(((
37 +**Servo Tx**: In serial mode, this pin sends the output from query commands. In RC mode, the cable does not need to be connected as there is no output.
35 35  )))
36 -|(% style="text-align:left; vertical-align:middle" %)[[image:[email protected]]]|(% style="text-align:left; vertical-align:middle" %)**#7, 8: **Ground (GND)
37 -|(% style="text-align:left; vertical-align:middle" %)[[image:[email protected]]]|(% style="text-align:left; vertical-align:middle" %)**#1, 2, 3, 6:** Not Connected
39 +|(% style="text-align:left; vertical-align:middle" %)[[image:[email protected]]]|(% style="text-align:left; vertical-align:middle" %)**Ground (GND)**: This pin should be connected to both the communication sources' ground, as well as that of the power source (principle of "common ground").
40 +|(% style="text-align:left; vertical-align:middle" %)[[image:[email protected]]]|(% style="text-align:left; vertical-align:middle" %)**Power: **
41 +|(% style="text-align:left; vertical-align:middle" %)[[image:[email protected]]]|(% style="text-align:left; vertical-align:middle" %)**Not Connected:** Those pins are un-connected
38 38  |(% colspan="3" style="width:350px" %)**Power**
39 39  |(% colspan="1" rowspan="2" style="width:350px" %)(((
40 -{{lightbox image="https://wiki.lynxmotion.com/info/wiki/lynxmotion/download/ses-pro/lss-pro/lss-p-electrical/WebHome/LSS-P-S1-Pinout-Power.png"/}}
41 -)))|(% style="text-align:left; vertical-align:middle" %)[[image:[email protected]||alt="SQUARE-Yellow.png"]]|(% style="text-align:left; vertical-align:middle" %)**Servo Vcc**: 30V or 36V nominal (40V MAX)
44 +{{lightbox image="https://wiki.lynxmotion.com/info/wiki/lynxmotion/download/lynxmotion-smart-servo-pro/lss-p-electrical/WebHome/LSS-P-S1-Pinout-Power.png"/}}
45 +)))|(% style="text-align:left; vertical-align:middle" %)[[image:[email protected]||alt="SQUARE-Yellow.png"]]|(% style="text-align:left; vertical-align:middle" %)**Servo Vcc**:
42 42  |(% style="text-align:left; vertical-align:middle" %)[[image:[email protected]||alt="SQUARE-Yellow.png"]]|(% style="text-align:left; vertical-align:middle" %)**Ground (GND)**:

Recently Visited

Copyright RobotShop 2018