Changes for page FlowArm LSS
Last modified by Eric Nantel on 2024/07/03 09:39
Change comment: There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Hidden
-
... ... @@ -1,1 +1,1 @@ 1 - true1 +false - Content
-
... ... @@ -337,12 +337,26 @@ 337 337 = Notifications = 338 338 339 339 340 +|(% style="text-align:center; width:500px" %)**Displayed Error**|(% style="text-align:center" %)**LSS Status**|(% style="text-align:center" %)**Informations** 341 +|(% style="width:500px" %)[[image:lss-flowarm-notification-limp.png]]|(% style="text-align:center; vertical-align:middle" %)[[image:LSS-UserColor.png||alt="LSS-Error-SafeMode.gif"]]|User clicked on the "LIMP" button or FlowArm noticed an error and put the arm in "LIMP" by himself. 342 +|[[image:lss-flowarm-notification-current.png]]|(% style="text-align:center; vertical-align:middle" %)[[image:LSS-Error-SafeMode.gif]]|((( 343 +FlowArm noticed a high current error on the specified servo (SERVO 4 in this example) 340 340 341 -(% style="width:700px" %) 342 -| | 343 -| | 344 -| | 345 +* Verify that noting is in the way of the servo that can block it's movement. 346 +* Try to "RELEASE SERVOS" which will "RESET" the servo(s) in error. 347 +))) 348 +|[[image:lss-flowarm-notification-temperature.png]]|(% style="text-align:center; vertical-align:middle" %)[[image:LSS-Error-SafeMode.gif]]|((( 349 +FlowArm noticed a high temperature error on the specified servo (SERVO 5 in this example). 345 345 351 +* Let it cool down for a minute. 352 +* Try to "RELEASE SERVOS" which will "RESET" the servo(s) in error. 353 +))) 354 +|[[image:lss-flowarm-notification-firmware.png]]|(% style="text-align:center; vertical-align:middle" %)[[image:LSS-UserColor.png||alt="LSS-Error-SafeMode.gif"]]|((( 355 +FlowArm noticed an earlier firmware version which is not compatible (SERVO 1 in this example). 356 + 357 +* As suggested, use the LSS-Config software to update the servo(s) 358 +))) 359 + 346 346 = Troubleshooting = 347 347 348 348 If you encounter any bugs or issues when installing or using the LSS FlowArm application, please submit a new post on the Lynxmotion community sub-forum here: [[https:~~/~~/www.robotshop.com/community/forum/c/lynxmotion/electronics-software>>url:https://www.robotshop.com/community/forum/c/lynxmotion/electronics-software]]
- LSS-Error-SafeMode.gif
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +xwiki:XWiki.ENantel - Size
-
... ... @@ -1,0 +1,1 @@ 1 +7.2 KB - Content
- LSS-UserColor.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +xwiki:XWiki.ENantel - Size
-
... ... @@ -1,0 +1,1 @@ 1 +10.6 KB - Content