Changes for page FlowArm LSS
Last modified by Eric Nantel on 2024/07/03 09:39
Change comment: There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -337,16 +337,35 @@ 337 337 = Notifications = 338 338 339 339 340 -Safe Mode 340 +(% style="width:1300px" %) 341 +|(% style="text-align:center; width:450px" %)**Displayed Error**|(% style="text-align:center; width:100px" %)**LED Status**|(% style="text-align:center" %)**Informations** 342 +|{{lightbox image="lss-flowarm-notification-limp.png"/}}|(% colspan="1" rowspan="2" style="text-align:center; vertical-align:middle" %)((( 343 +[[image:LSS-UserColor.png||alt="LSS-Error-SafeMode.gif"]] 341 341 345 +User Defined 346 +)))|User clicked on the "LIMP" button or FlowArm noticed an error and put the arm in "LIMP" by himself. 347 +|{{lightbox image="lss-flowarm-notification-firmware.png"/}}|((( 348 +FlowArm noticed an earlier firmware version which is not compatible (SERVO 1 in this example). 349 + 350 +* As suggested, use the LSS-Config software to update the servo(s) 351 +))) 352 +|{{lightbox image="lss-flowarm-notification-current.png"/}}|(% colspan="1" rowspan="2" style="text-align:center; vertical-align:middle" %)((( 342 342 [[image:LSS-Error-SafeMode.gif]] 343 343 344 -(% style="width:700px" %) 345 -|[[image:lss-flowarm-notification-limp.png]]| 346 -|[[image:lss-flowarm-notification-current.png]]| 347 -|[[image:lss-flowarm-notification-temperature.png]]| 348 -|[[image:lss-flowarm-notification-firmware.png]]| 355 +Red Flashing 356 +)))|((( 357 +FlowArm noticed a high current error on the specified servo (SERVO 4 in this example) 349 349 359 +* Verify that noting is in the way of the servo that can block it's movement. 360 +* Try to "RELEASE SERVOS" which will "RESET" the servo(s) in error. 361 +))) 362 +|{{lightbox image="lss-flowarm-notification-temperature.png"/}}|((( 363 +FlowArm noticed a high temperature error on the specified servo (SERVO 5 in this example). 364 + 365 +* Let it cool down for a minute. 366 +* Try to "RELEASE SERVOS" which will "RESET" the servo(s) in error. 367 +))) 368 + 350 350 = Troubleshooting = 351 351 352 352 If you encounter any bugs or issues when installing or using the LSS FlowArm application, please submit a new post on the Lynxmotion community sub-forum here: [[https:~~/~~/www.robotshop.com/community/forum/c/lynxmotion/electronics-software>>url:https://www.robotshop.com/community/forum/c/lynxmotion/electronics-software]]
- LSS-UserColor.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +xwiki:XWiki.ENantel - Size
-
... ... @@ -1,0 +1,1 @@ 1 +10.6 KB - Content