Changes for page FlowArm LSS
Last modified by Eric Nantel on 2024/07/03 09:39
Change comment: There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -337,29 +337,34 @@ 337 337 = Notifications = 338 338 339 339 340 +|(% style="text-align:center; width:501px" %)**Displayed Error**|(% style="text-align:center; width:130px" %)**LED Status**|(% style="text-align:center" %)**Informations** 341 +|(% style="width:501px" %)[[image:lss-flowarm-notification-limp.png]]|(% colspan="1" rowspan="2" style="text-align:center; vertical-align:middle; width:130px" %)((( 342 +[[image:LSS-UserColor.png||alt="LSS-Error-SafeMode.gif"]] 340 340 344 +User Defined 345 +)))|User clicked on the "LIMP" button or FlowArm noticed an error and put the arm in "LIMP" by himself. 346 +|(% style="width:501px" %)[[image:lss-flowarm-notification-firmware.png]]|((( 347 +FlowArm noticed an earlier firmware version which is not compatible (SERVO 1 in this example). 348 + 349 +* As suggested, use the LSS-Config software to update the servo(s) 350 +))) 351 +|(% style="width:501px" %)[[image:lss-flowarm-notification-current.png]]|(% colspan="1" rowspan="2" style="text-align:center; vertical-align:middle; width:130px" %)((( 341 341 [[image:LSS-Error-SafeMode.gif]] 342 342 343 -|(% style="text-align:center; width:500px" %)**Displayed Error**|(% style="text-align:center" %)**LSS Status**|(% style="text-align:center" %)**Informations** 344 -|(% style="width:500px" %)[[image:lss-flowarm-notification-limp.png]]|(% style="text-align:center; vertical-align:middle" %)Normal|User clicked on the "LIMP" button or FlowArm noticed an error and put the arm in "LIMP" by himself. 345 -|[[image:lss-flowarm-notification-current.png]]|(% style="text-align:center; vertical-align:middle" %)[[image:LSS-Error-SafeMode.gif]]|((( 354 +Red Flashing 355 +)))|((( 346 346 FlowArm noticed a high current error on the specified servo (SERVO 4 in this example) 347 347 348 348 * Verify that noting is in the way of the servo that can block it's movement. 349 349 * Try to "RELEASE SERVOS" which will "RESET" the servo(s) in error. 350 350 ))) 351 -|[[image:lss-flowarm-notification-temperature.png]]|( % style="text-align:center; vertical-align:middle" %)[[image:LSS-Error-SafeMode.gif]]|(((361 +|(% style="width:501px" %)[[image:lss-flowarm-notification-temperature.png]]|((( 352 352 FlowArm noticed a high temperature error on the specified servo (SERVO 5 in this example). 353 353 354 354 * Let it cool down for a minute. 355 355 * Try to "RELEASE SERVOS" which will "RESET" the servo(s) in error. 356 356 ))) 357 -|[[image:lss-flowarm-notification-firmware.png]]|(% style="text-align:center; vertical-align:middle" %)Normal|((( 358 -FlowArm noticed an earlier firmware version which is not compatible (SERVO 1 in this example). 359 359 360 -* As suggested, use the LSS-Config software to update the servo(s) 361 -))) 362 - 363 363 = Troubleshooting = 364 364 365 365 If you encounter any bugs or issues when installing or using the LSS FlowArm application, please submit a new post on the Lynxmotion community sub-forum here: [[https:~~/~~/www.robotshop.com/community/forum/c/lynxmotion/electronics-software>>url:https://www.robotshop.com/community/forum/c/lynxmotion/electronics-software]]
- LSS-UserColor.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +xwiki:XWiki.ENantel - Size
-
... ... @@ -1,0 +1,1 @@ 1 +10.6 KB - Content