Changes for page FlowArm LSS
Last modified by Eric Nantel on 2024/07/03 09:39
Change comment: There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -337,34 +337,26 @@ 337 337 = Notifications = 338 338 339 339 340 -|(% style="text-align:center; width:501px" %)**Displayed Error**|(% style="text-align:center; width:130px" %)**LED Status**|(% style="text-align:center" %)**Informations** 341 -|(% style="width:501px" %)[[image:lss-flowarm-notification-limp.png]]|(% colspan="1" rowspan="2" style="text-align:center; vertical-align:middle; width:130px" %)((( 342 -[[image:LSS-UserColor.png||alt="LSS-Error-SafeMode.gif"]] 343 - 344 -User Defined 345 -)))|User clicked on the "LIMP" button or FlowArm noticed an error and put the arm in "LIMP" by himself. 346 -|(% style="width:501px" %)[[image:lss-flowarm-notification-firmware.png]]|((( 347 -FlowArm noticed an earlier firmware version which is not compatible (SERVO 1 in this example). 348 - 349 -* As suggested, use the LSS-Config software to update the servo(s) 350 -))) 351 -|(% style="width:501px" %)[[image:lss-flowarm-notification-current.png]]|(% colspan="1" rowspan="2" style="text-align:center; vertical-align:middle; width:130px" %)((( 352 -[[image:LSS-Error-SafeMode.gif]] 353 - 354 -Red Flashing 355 -)))|((( 340 +|(% style="text-align:center; width:500px" %)**Displayed Error**|(% style="text-align:center" %)**LSS Status**|(% style="text-align:center" %)**Informations** 341 +|(% style="width:500px" %)[[image:lss-flowarm-notification-limp.png]]|(% style="text-align:center; vertical-align:middle" %)[[image:LSS-UserColor.png||alt="LSS-Error-SafeMode.gif"]]|User clicked on the "LIMP" button or FlowArm noticed an error and put the arm in "LIMP" by himself. 342 +|[[image:lss-flowarm-notification-current.png]]|(% style="text-align:center; vertical-align:middle" %)[[image:LSS-Error-SafeMode.gif]]|((( 356 356 FlowArm noticed a high current error on the specified servo (SERVO 4 in this example) 357 357 358 358 * Verify that noting is in the way of the servo that can block it's movement. 359 359 * Try to "RELEASE SERVOS" which will "RESET" the servo(s) in error. 360 360 ))) 361 -| (% style="width:501px" %)[[image:lss-flowarm-notification-temperature.png]]|(((348 +|[[image:lss-flowarm-notification-temperature.png]]|(% style="text-align:center; vertical-align:middle" %)[[image:LSS-Error-SafeMode.gif]]|((( 362 362 FlowArm noticed a high temperature error on the specified servo (SERVO 5 in this example). 363 363 364 364 * Let it cool down for a minute. 365 365 * Try to "RELEASE SERVOS" which will "RESET" the servo(s) in error. 366 366 ))) 354 +|[[image:lss-flowarm-notification-firmware.png]]|(% style="text-align:center; vertical-align:middle" %)[[image:LSS-UserColor.png||alt="LSS-Error-SafeMode.gif"]]|((( 355 +FlowArm noticed an earlier firmware version which is not compatible (SERVO 1 in this example). 367 367 357 +* As suggested, use the LSS-Config software to update the servo(s) 358 +))) 359 + 368 368 = Troubleshooting = 369 369 370 370 If you encounter any bugs or issues when installing or using the LSS FlowArm application, please submit a new post on the Lynxmotion community sub-forum here: [[https:~~/~~/www.robotshop.com/community/forum/c/lynxmotion/electronics-software>>url:https://www.robotshop.com/community/forum/c/lynxmotion/electronics-software]]