... ... @@ -337,35 +337,29 @@
337 337  = Notifications =
338 338  
339 339  
340 -(% style="width:1300px" %)
341 -|(% style="text-align:center; width:450px" %)**Displayed Error**|(% style="text-align:center; width:100px" %)**LED Status**|(% style="text-align:center" %)**Informations**
342 -|{{lightbox image="lss-flowarm-notification-limp.png"/}}|(% colspan="1" rowspan="2" style="text-align:center; vertical-align:middle" %)(((
343 -[[image:LSS-UserColor.png||alt="LSS-Error-SafeMode.gif"]]
344 344  
345 -User Defined
346 -)))|User clicked on the "LIMP" button or FlowArm noticed an error and put the arm in "LIMP" by himself.
347 -|{{lightbox image="lss-flowarm-notification-firmware.png"/}}|(((
348 -FlowArm noticed an earlier firmware version which is not compatible (SERVO 1 in this example).
349 -
350 -* As suggested, use the LSS-Config software to update the servo(s)
351 -)))
352 -|{{lightbox image="lss-flowarm-notification-current.png"/}}|(% colspan="1" rowspan="2" style="text-align:center; vertical-align:middle" %)(((
353 353  [[image:LSS-Error-SafeMode.gif]]
354 354  
355 -Red Flashing
356 -)))|(((
343 +|(% style="text-align:center; width:500px" %)**Displayed Error**|(% style="text-align:center" %)**LSS Status**|(% style="text-align:center" %)**Informations**
344 +|(% style="width:500px" %)[[image:lss-flowarm-notification-limp.png]]|(% style="text-align:center; vertical-align:middle" %)Normal|User clicked on the "LIMP" button or FlowArm noticed an error and put the arm in "LIMP" by himself.
345 +|[[image:lss-flowarm-notification-current.png]]|(% style="text-align:center; vertical-align:middle" %)[[image:LSS-Error-SafeMode.gif]]|(((
357 357  FlowArm noticed a high current error on the specified servo (SERVO 4 in this example)
358 358  
359 359  * Verify that noting is in the way of the servo that can block it's movement.
360 360  * Try to "RELEASE SERVOS" which will "RESET" the servo(s) in error.
361 361  )))
362 -|{{lightbox image="lss-flowarm-notification-temperature.png"/}}|(((
351 +|[[image:lss-flowarm-notification-temperature.png]]|(% style="text-align:center; vertical-align:middle" %)[[image:LSS-Error-SafeMode.gif]]|(((
363 363  FlowArm noticed a high temperature error on the specified servo (SERVO 5 in this example).
364 364  
365 365  * Let it cool down for a minute.
366 366  * Try to "RELEASE SERVOS" which will "RESET" the servo(s) in error.
367 367  )))
357 +|[[image:lss-flowarm-notification-firmware.png]]|(% style="text-align:center; vertical-align:middle" %)Normal|(((
358 +FlowArm noticed an earlier firmware version which is not compatible (SERVO 1 in this example).
368 368  
360 +* As suggested, use the LSS-Config software to update the servo(s)
361 +)))
362 +
369 369  = Troubleshooting =
370 370  
371 371  If you encounter any bugs or issues when installing or using the LSS FlowArm application, please submit a new post on the Lynxmotion community sub-forum here: [[https:~~/~~/www.robotshop.com/community/forum/c/lynxmotion/electronics-software>>url:https://www.robotshop.com/community/forum/c/lynxmotion/electronics-software]]
LSS-UserColor.png
Author
... ... @@ -1,1 +1,0 @@
1 -xwiki:XWiki.ENantel
Size
... ... @@ -1,1 +1,0 @@
1 -10.6 KB
Content
Copyright RobotShop 2018