Changes for page FlowArm LSS
Last modified by Eric Nantel on 2024/07/03 09:39
Change comment: Upload new image "lss-flowarm-left.png", version 1.1
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -57,8 +57,12 @@ 57 57 58 58 == Header == 59 59 60 -[[image:lss-flowarm-header. jpg]]60 +[[image:lss-flowarm-header.png||alt="lss-flowarm-header"]] 61 61 62 +**EMERGENCY STOP** 63 + 64 +At any given time you can click this button to stop the arm. This will send a "LIMP" command directly to all servos. 65 + 62 62 **STORE OFFSETS** 63 63 64 64 The "STORE OFFSETS" button configures all of the servo offsets (this makes use of the CO command as part of the [[LSS Communication Protocol>>doc:lynxmotion-smart-servo.lss-communication-protocol.WebHome]]). Before pressing the button, orient the arm as shown below (with the gripper closed), and only then click the STORE OFFSETS button. ... ... @@ -73,7 +73,7 @@ 73 73 74 74 **LIMP** 75 75 76 -Causes all servos to immediately go LIMP (i.e. lose torque).The arm willcollapse. It's important to note that the software will not constantly query all servos for their position, and as such the virtual arm on screen will not update frequently if at all. If you want the virtual arm on screen to update as you move the real arm, use TEACH mode described below.80 +Causes all servos to slowly go LIMP (i.e. lose torque), gradually loosing torque until hitting the ground. It's important to note that the software will not constantly query all servos for their position, and as such the virtual arm on screen will not update frequently if at all. If you want the virtual arm on screen to update as you move the real arm, use TEACH mode described below. 77 77 78 78 **STOP** 79 79 ... ... @@ -295,7 +295,10 @@ 295 295 296 296 **Frame Inspector** 297 297 302 +[[image:lss-flowarm-inspector-frame.png]] 298 298 304 +If any adjustments are required on a particular joint (servo) this function allows you to manually change them. Click on the particular frame and the commands can be edited. 305 + 299 299 == Sequencer == 300 300 301 301 **Reverse Frames**
- lss-flowarm-header.jpg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -xwiki:XWiki.CBenson - Size
-
... ... @@ -1,1 +1,0 @@ 1 -17.7 KB - Content
- lss-flowarm-header.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +xwiki:XWiki.ENantel - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.4 KB - Content
- lss-flowarm-left.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +xwiki:XWiki.ENantel - Size
-
... ... @@ -1,0 +1,1 @@ 1 +11.2 KB - Content