Changes for page LSS-PRO CAN Bus

Last modified by Eric Nantel on 2025/03/24 07:17

From version < 11.1 >
edited by Eric Nantel
on 2024/11/25 14:43
To version < 12.1 >
edited by Eric Nantel
on 2024/11/25 14:55
< >
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -19,12 +19,12 @@
19 19  |(% colspan="2" rowspan="1" style="text-align:center" %)**Data format on USB-Serial**|(% rowspan="16" style="text-align:center" %) |(% colspan="3" rowspan="1" style="text-align:center" %)**Data format on CAN-Bus**
20 20  |(% colspan="2" rowspan="1" style="width:150px" %) |(% style="width:150px" %)ID[28-20]|(% style="width:300px" %)Reserved|
21 21  |(% style="background-color:yellow; width:150px" %)Header|(% style="background-color:yellow" %)# or *|(% style="background-color:yellow" %)ID[19]|(% style="background-color:yellow" %)Request/Response (0:Request 1:Response)|(% style="background-color:yellow" %)# = 0, * = 1
22 -|(% colspan="2" rowspan="3" %) |ID[18]|Presence of command parameters|Set to 1 if there are parameters such as D commands, set to 0 if there are parameters such as Query commands, etc.
23 -|ID[17]|Presence of sub-command id|Set to 1 if there is a Modifier command (SD/T), otherwise set to 0.
24 -|ID[16]|Presence of sub-command parameter|Set to 1 if there is a parameter for the Modifier command, otherwise set to 0.
22 +|(% colspan="2" rowspan="3" %) |(% style="background-color:#dbd3ba" %)ID[18]|(% style="background-color:#dbd3ba" %)Presence of command parameters|(% style="background-color:#dbd3ba" %)Set to 1 if there are parameters such as D commands, set to 0 if there are parameters such as Query commands, etc.
23 +|(% style="background-color:#bdac7b" %)ID[17]|(% style="background-color:#bdac7b" %)Presence of sub-command id|(% style="background-color:#bdac7b" %)Set to 1 if there is a Modifier command (SD/T), otherwise set to 0.
24 +|(% style="background-color:#bcd6f5" %)ID[16]|(% style="background-color:#bcd6f5" %)Presence of sub-command parameter|(% style="background-color:#bcd6f5" %)Set to 1 if there is a parameter for the Modifier command, otherwise set to 0.
25 25  (SD/T requires a parameter, so currently if ID[17] is 1, ID[16] will also be 1.)
26 26  |(% style="background-color:#22e817" %)ServoID|(% style="background-color:#22e817" %)Servo ID|(% style="background-color:#22e817" %)ID[15-8]|(% style="background-color:#22e817" %)Source ID|(% style="background-color:#22e817" %)
27 -|(% colspan="2" rowspan="1" %) |ID[7-0]|Destination ID|
27 +|(% colspan="2" rowspan="1" %) |(% style="background-color:#22e817" %)ID[7-0]|(% style="background-color:#22e817" %)Destination ID|(% style="background-color:#22e817" %)
28 28  |(% style="background-color:orange" %)Command|(% style="background-color:orange" %)Action Command (ex. RESET, D, etc..)
29 29  Query Command (ex. QID, QD, etc...)
30 30  Configuration Command (ex. CID, etc...)|(% style="background-color:orange" %)DATA0|(% style="background-color:orange" %)Command ID|(% style="background-color:orange" %)See Command ID List.
Copyright RobotShop 2018