Changes for page LSS-PRO Configuration Software
Last modified by Eric Nantel on 2024/10/04 08:08
Change comment: There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 4 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -28,24 +28,55 @@ 28 28 29 29 == Status == 30 30 31 -[ lorrenIpsum]31 +[[image:LSS-P-Config-Status.png]] 32 32 33 +This is a section to directly give information to the user on what's happening with their actuator. 34 + 35 +1. Position of the actuator including any adjustment to the Origin Offset. 36 +1. Status of what the actuator is currently doing. (A list of the different statuses is available HERE) 37 +1. Errors that are happening. (A list of the different errors is available HERE) 38 + 33 33 == Query == 34 34 35 -[ lorrenIpsum]41 +[[image:LSS-P-Config-Query.png]] 36 36 43 + 44 +1. Use the drop down menu to select the available Query. A quick explanation is provided in text but for more information click HERE. 45 +1. Click the "Send" button to initiate the Query. 46 +1. The Query protocol command will be displayed here as well as the answer from the actuator. (ex: #1QID / *1QID1) 47 + 37 37 == Action == 38 38 39 -[ lorrenIpsum]50 +[[image:LSS-P-Config-Action.png]] 40 40 52 + 53 + 54 +1. Use the drop down menu to select the available Action. A quick explanation is provided in text but for more information click HERE. 55 +1. Input the value of the Action required in the text input field. (ex: 9000 for a 90deg move) 56 +1. Click the "Send" button to initiate the Action. 57 +1. The Action protocol command will be displayed here and the actuator should be doing it. 58 + 41 41 == Configuration == 42 42 43 -[ lorrenIpsum]61 +[[image:LSS-P-Config-Config.png]] 44 44 63 +1. Use the drop down menu to select the available Configuration. A quick explanation is provided in text but for more information click HERE. 64 +1. Input the value of the Configurationrequired in the text input field. (ex: 1 for an ID change to 1) 65 +1. Click the "Send" button to initiate the Configuration. 66 +1. The Configuration protocol command will be displayed here. 67 + 45 45 == Telemetry == 46 46 47 - [lorrenIpsum]70 +The graph within the software is used to display output of any query commands, which can include sensor data or calculated data. To activate a specific value, click on the button and click again to disable it. 48 48 72 +To change the query for a specific button, you have to do a "CTRL + CLICK" on the desired button, this interface will then be displayed. 73 + 74 +[[image:LSS-P-Config-Telemetry-Custom.png]] 75 + 76 +1. Trace Name: Displayed name for that particular query. 77 +1. Two separate "Add" button and drop down are present, they are shortcuts to add to the query bellow. 78 +1. Actual query that will be sent to the actuator plus displayed units for the interface. 79 + 49 49 == Custom Actions == 50 50 51 51 [lorren Ipsum]
- LSS-P-Config-Action.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +xwiki:XWiki.ENantel - Size
-
... ... @@ -1,0 +1,1 @@ 1 +105.0 KB - Content
- LSS-P-Config-Config.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +xwiki:XWiki.ENantel - Size
-
... ... @@ -1,0 +1,1 @@ 1 +105.1 KB - Content
- LSS-P-Config-Query.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +xwiki:XWiki.ENantel - Size
-
... ... @@ -1,0 +1,1 @@ 1 +103.4 KB - Content
- LSS-P-Config-Telemetry-Custom.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +xwiki:XWiki.ENantel - Size
-
... ... @@ -1,0 +1,1 @@ 1 +5.3 KB - Content