Changes for page LSS-PRO Configuration Software
Last modified by Eric Nantel on 2024/10/04 08:08
Change comment: There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -56,14 +56,13 @@ 56 56 57 57 Note: Most errors will require the problem to be solved & the servo either Reset or set Limp. 58 58 59 -(% class="wikigeneratedid" %) 60 -= Servo Control = 59 +== Servo Control == 61 61 62 62 [[image:LSS-P-Config-ServoControl.png]] 63 63 64 64 In order to view the various commands available for each drop-down, a PRO servo needs to be properly connected to the computer, powered, turned on and detected 65 65 66 -== Query == 65 +=== Query === 67 67 68 68 The drop down list below Query provides a list of most query commands possible. 69 69 ... ... @@ -73,7 +73,7 @@ 73 73 1. Click the "Send" button to initiate the Query. 74 74 1. The Query protocol command will be displayed here as well as the answer from the actuator. (ex: #1QID / *1QID1) 75 75 76 -== Action == 75 +=== Action === 77 77 78 78 The drop down list below Action provides a list of most action commands used with the LSS PRO servos. 79 79 ... ... @@ -84,7 +84,7 @@ 84 84 1. Click the "Send" button to initiate the Action. 85 85 1. The Action protocol command will be displayed here and the actuator should be doing it. 86 86 87 -== Configuration == 86 +=== Configuration === 88 88 89 89 The drop down list below Configuration provides a list of most configuration commands used with the LSS PRO servos. 90 90 ... ... @@ -91,7 +91,7 @@ 91 91 [[image:LSS-P-Config-Config.png]] 92 92 93 93 1. Use the drop down menu to select the available Configuration. A quick explanation is provided in text but for more information click HERE. 94 -1. Input the value of the Configurationrequired in the text input field. (ex: 1 for an ID change to 1) 93 +1. Input the value of the Configuration required in the text input field. (ex: 1 for an ID change to 1) 95 95 1. Click the "Send" button to initiate the Configuration. 96 96 1. The Configuration protocol command will be displayed here. 97 97 ... ... @@ -103,10 +103,19 @@ 103 103 104 104 == Telemetry == 105 105 106 - Thegraph within the software is used to display output of any query commands, which can include sensor data or calculated data.To activate a specific value, click on the button and click again to disable it.105 +A graph within the software is used to display output of any query commands, which can include sensor data or calculated data. 107 107 108 - ===CustomQuery===107 +[[image:LSS-P-Config-Telemetry.png]] 109 109 109 +1. To activate a specific value, click on the button and click again to disable it. he software start memorizing the data as soon as one query is activated. 110 +1. Pause will stop recording until you click back on it. 111 +1. Restart will wipe all the recorded values. 112 +1. The Y-axis of the graph auto-scales depending on what output is selected. To switch between traces, use the mouse wheel and confirm that the y axis label is the one you selected. 113 +1. The X-axis display the time & expands up to 20 minutes then scrolls a 20 minute time window. 114 +1. Saving the data is possible by doing a right click on the graph and select Copy, it's then possible to paste them in a spreadsheet application (Excel / Google Sheets) 115 + 116 +=== Personalize Query === 117 + 110 110 To change the query for a specific button, you have to do a "CTRL + CLICK" on the desired button, this interface will then be displayed. 111 111 112 112 [[image:LSS-P-Config-Telemetry-Custom.png]] ... ... @@ -117,12 +117,11 @@ 117 117 118 118 === Saving Data === 119 119 128 + 120 120 == Custom Actions == 121 121 122 122 [lorren Ipsum] 123 123 124 -== == 125 - 126 126 == Firmware Update == 127 127 128 128 [lorren Ipsum]
- LSS-P-Config-Telemetry.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +xwiki:XWiki.ENantel - Size
-
... ... @@ -1,0 +1,1 @@ 1 +69.1 KB - Content