... ... @@ -1,23 +1,59 @@
1 -
1 += Step 1 - Connections =
2 2  
3 +__Warning: Make sure your power supply is OFF and wait at least 10s before connecting to the LSS-P actuator.__
3 3  
4 -|(% colspan="2" %)Step 1
5 -|(% style="width:30px" %) |While your power supply is OFF (important) connect the Servo power and USB cables
6 -|(% colspan="2" %)Step 2
7 -| |Power up your supply
8 -|(% colspan="2" %)
9 -| |Open the LSS PRO Configuration software (HERE)
10 -|(% colspan="2" %)
11 -| |Select the COM port associated with your actuator & connect
12 -|(% colspan="2" %)
13 -| |Select your actuator from the drop-down list
14 -|(% colspan="2" %)
15 -| |Select the CID configuration command in the list
16 -|(% colspan="2" %)
17 -| |Set the desired ID in the text box
18 -|(% colspan="2" %)
19 -| |Send your command
20 -|(% colspan="2" %)
21 -| |Reset your actuator
5 +* (((
6 +Connect the XT60 from your power supply
7 +)))
8 +* Connect the USB Type-C cable
22 22  
23 -
10 += Step 2 - Power-Up =
11 +
12 +* Proceed with powering the actuator
13 +
14 += Step 3 - Software =
15 +
16 +* Install the LSS PRO Configuration software ([[HERE>>doc:ses-pro.lss-pro.lss-p-configuration-software.WebHome]])
17 +* Open the LSS PRO Configuration software
18 +
19 +[[image:LSS-P-ID-Config-Open.png]]
20 +
21 += Step 4 - Connection =
22 +
23 +* Select the COM port associated with your actuator
24 +* Click Connect
25 +
26 +[[image:LSS-P-ID-Config-COM.png]]
27 +
28 += Step 5 - Selection =
29 +
30 +* In the drop-down menu, select your actuator
31 +
32 +[[image:LSS-P-ID-Config-Select.png]]
33 +
34 += Step 6 - Set the ID =
35 +
36 +* In the "Configuration" drop-down menu, select "CID / ID Number"
37 +
38 +[[image:LSS-P-ID-Config-CID.png]]
39 +
40 +* In the text entry box, set the desired ID number
41 +
42 +[[image:LSS-P-ID-Config-ID1.png]]
43 +
44 +* Click on the "Send" button
45 +
46 +[[image:LSS-P-ID-Config-Send.png]]
47 +
48 +* The "RESET" button will start blinking, click on it to reset
49 +
50 +[[image:LSS-P-ID-Config-Reset.png]]
51 +
52 += Step 7 - Confirm =
53 +
54 +* The software will automatically re-connect to the actuator but if not you can do it manually like in Step 4
55 +* Verify that your ID is not what you have set it at
56 +
57 +[[image:LSS-P-ID-Config-ID1-Confirm.png]]
58 +
59 +At that point your Actuator should have the new ID configured.
LSS-P-ID-Config-CID.png
Author
... ... @@ -1,0 +1,1 @@
1 +xwiki:XWiki.ENantel
Size
... ... @@ -1,0 +1,1 @@
1 +33.9 KB
Content
LSS-P-ID-Config-COM.png
Author
... ... @@ -1,0 +1,1 @@
1 +xwiki:XWiki.ENantel
Size
... ... @@ -1,0 +1,1 @@
1 +12.4 KB
Content
LSS-P-ID-Config-ID1-Confirm.png
Author
... ... @@ -1,0 +1,1 @@
1 +xwiki:XWiki.ENantel
Size
... ... @@ -1,0 +1,1 @@
1 +6.6 KB
Content
LSS-P-ID-Config-ID1.png
Author
... ... @@ -1,0 +1,1 @@
1 +xwiki:XWiki.ENantel
Size
... ... @@ -1,0 +1,1 @@
1 +17.4 KB
Content
LSS-P-ID-Config-Open.png
Author
... ... @@ -1,0 +1,1 @@
1 +xwiki:XWiki.ENantel
Size
... ... @@ -1,0 +1,1 @@
1 +178.7 KB
Content
LSS-P-ID-Config-Reset.png
Author
... ... @@ -1,0 +1,1 @@
1 +xwiki:XWiki.ENantel
Size
... ... @@ -1,0 +1,1 @@
1 +7.8 KB
Content
LSS-P-ID-Config-Select.png
Author
... ... @@ -1,0 +1,1 @@
1 +xwiki:XWiki.ENantel
Size
... ... @@ -1,0 +1,1 @@
1 +6.5 KB
Content
LSS-P-ID-Config-Send.png
Author
... ... @@ -1,0 +1,1 @@
1 +xwiki:XWiki.ENantel
Size
... ... @@ -1,0 +1,1 @@
1 +17.5 KB
Content
Copyright RobotShop 2018