Changes for page LSS FlowArm - Setup
Last modified by Eric Nantel on 2023/02/21 10:31
Change comment: There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -16,26 +16,10 @@ 16 16 17 17 (% style="width:700px" %) 18 18 |(% colspan="5" %)**Calibration (Store Offsets)** 19 -|(% style="width:10px" %) |(% colspan="4" %)1. Click on the "Teach" button 20 -|(% style="width:10px" %) |(% colspan="4" rowspan="1" %) 21 -| |(% colspan="4" %)2. Power the arm using the power supply ON/OFF switch. 22 -| |(% colspan="4" %)((( 23 -4. Select the type of LSS Arm you are using (3 DoF / 4 DoF / 5 DoF) 24 - 25 -It will automatically try to find the connected Arm but, if not, you can manually choose the appropriate COM port from the drop-down list & the baud rate (default is 115200) 26 -))) 27 -| |(% colspan="4" %){{lightbox image="LSS-FlowArm-Arm-Selection.png"/}} 28 -| |(% colspan="4" %)5. The software sends a query to servo ID1 and once a reply is received, it determines connection has been established and a green light will be displayed aside the COM port. 29 - 30 -= Calibration = 31 - 32 -1. Go in "TEACH" mode with the button on the top bar. 33 -1. Manually place the arm in the correct position for your model and with the gripper closed. (see images bellow) 34 -1. Store the values or Offsets by clicking "STORE OFFSETS" 35 -1. At that point the arm should "stay" in that position once released 36 -1. Exit the "TEACH" mode by clicking it again 37 - 38 -= Calibration Positions = 39 - 40 -|(% colspan="2" rowspan="1" style="text-align:center; vertical-align:middle" %)**4 DoF**|(% colspan="2" rowspan="1" style="text-align:center; vertical-align:middle" %)**3 DoF ** 41 -|(% style="text-align:center; vertical-align:middle" %)[[image:[email protected]||width="200"]]|(% style="text-align:center; vertical-align:middle" %)[[image:[email protected]||width="200"]]|(% style="text-align:center; vertical-align:middle" %)[[image:[email protected]||width="200"]]|(% style="text-align:center; vertical-align:middle" %)[[image:[email protected]||alt="lss-flowarm-left-3dof.png" width="200"]] 19 +|(% style="width:10px" %) |(% colspan="4" %)1. Go in "TEACH" mode with the button on the top bar. 20 +|(% style="width:10px" %) |(% colspan="4" rowspan="1" %)2. Manually place the arm in the correct position for your model and with the gripper closed. (see images bellow) 21 +|(% style="width:10px" %) |(% colspan="4" %) 22 +|(% style="width:10px" %) |(% colspan="4" %)3. Store the values or Offsets by clicking "STORE OFFSETS" 23 +|(% style="width:10px" %) |(% colspan="4" %)4.At that point the arm should "stay" in that position once released 24 +|(% style="width:10px" %) |(% colspan="4" %)5. Exit the "TEACH" mode by clicking it again 25 +|(% style="width:10px" %) |(% colspan="4" %)