Wiki source code of LSS - Communication Protocol

Version 85.1 by RB1 on 2019/01/23 10:52

Hide last authors
Eric Nantel 79.1 1 (% class="wikigeneratedid" id="HTableofContents" %)
2 **Table of Contents**
Coleman Benson 67.1 3
RB1 64.5 4 {{toc depth="3"/}}
5
Coleman Benson 68.1 6 = Protocol Concepts =
RB1 64.19 7
Coleman Benson 1.1 8 The Lynxmotion Smart Servo (LSS) protocol was created in order to be as simple and straightforward as possible from a user perspective, while at the same time trying to stay compact and robust yet highly versatile. Almost everything one might expect to be able to configure for a smart servo motor is available.
9
RB1 64.2 10 == Session ==
Coleman Benson 1.1 11
12 A "session" is defined as the time between when the servo is powered ON to when it is powered OFF or reset.
13
14 == Action Commands ==
15
16 Action commands are sent serially to the servo's Rx pin and must be set in the following format:
17
18 1. Start with a number sign # (U+0023)
19 1. Servo ID number as an integer
20 1. Action command (one to three letters, no spaces, capital or lower case)
21 1. Action value in the correct units with no decimal
22 1. End with a control / carriage return '<cr>'
23
24 (((
25 Ex: #5PD1443<cr>
26
27 Move servo with ID #5 to a position of 144.3 degrees.
28
29 Action commands cannot be combined with query commands, and only one action command can be sent at a time.
30
31 Action commands are session-specific, therefore once a servo is power cycled, it will not have any "memory" of previous actions or virtual positions (as described at the bottom of this page).
32
Coleman Benson 65.2 33 == Action Modifiers ==
Coleman Benson 1.1 34
35 Two commands can be used as action modifiers only: Timed Move and Speed. The format is:
36
37 1. Start with a number sign # (U+0023)
38 1. Servo ID number as an integer
39 1. Action command (one to three letters, no spaces, capital or lower case)
40 1. Action value in the correct units with no decimal
41 1. Modifier command (one letter)
42 1. Modifier value in the correct units with no decimal
43 1. End with a control / carriage return '<cr>'
44
45 Ex: #5P1456T1263<cr>
46
47 Results in the servo rotating from the current angular position to a pulse position of 1456 in 1263 milliseconds.
48
RB1 55.1 49 Action modifiers can only be used with certain commands.
Coleman Benson 1.1 50 )))
51
Coleman Benson 16.1 52 == Configuration Commands ==
53
RB1 77.1 54 Configuration commands affect the servo's current session* but unlike action commands, configuration commands are written to EEPROM and are retained even if the servo loses power (therefore NOT session specific). Not all action commands have a corresponding configuration and vice versa. Certain configurations are retained for when the servo is used in RC model. More information can be found on the [[LSS - RC PWM page>>doc:Lynxmotion Smart Servo (LSS).LSS - RC PWM.WebHome]].
Coleman Benson 16.1 55
56 1. Start with a number sign # (U+0023)
57 1. Servo ID number as an integer
58 1. Configuration command (two to three letters, no spaces, capital or lower case)
59 1. Configuration value in the correct units with no decimal
60 1. End with a control / carriage return '<cr>'
61
62 Ex: #5CO-50<cr>
63
64 Assigns an absolute origin offset of -5.0 degrees (with respect to factory origin) to servo #5 and changes the offset for that session to -5.0 degrees.
65
66 Configuration commands are not cumulative, in that if two configurations are sent at any time, only the last configuration is used and stored.
67
68 *Important Note: the one exception is the baud rate - the servo's current session retains the given baud rate. The new baud rate will only be in place when the servo is power cycled.
69
Coleman Benson 1.1 70 == Query Commands ==
71
72 Query commands are sent serially to the servo's Rx pin and must be set in the following format:
73
74 1. Start with a number sign # (U+0023)
75 1. Servo ID number as an integer
76 1. Query command (one to three letters, no spaces, capital or lower case)
77 1. End with a control / carriage return '<cr>'
78
79 (((
80 Ex: #5QD<cr>Query position in degrees for servo #5
81 )))
82
83 (((
84 The query will return a value via the Tx pin with the following format:
85
86 1. Start with an asterisk (U+002A)
87 1. Servo ID number as an integer
88 1. Query command (one to three letters, no spaces, capital letters)
89 1. The reported value in the units described, no decimals.
90 1. End with a control / carriage return '<cr>'
91
92 (((
93 Ex: *5QD1443<cr>
94 )))
95
96 Indicates that servo #5 is currently at 144.3 degrees.
97
Coleman Benson 16.1 98 **Session vs Configuration Query**
Coleman Benson 1.1 99
Coleman Benson 16.1 100 By default, the query command returns the sessions' value; should no action commands have been sent to change, it will return the value saved in EEPROM from the last configuration command.
Coleman Benson 1.1 101
Coleman Benson 16.1 102 In order to query the value in EEPROM, add a '1' to the query command.
Coleman Benson 1.1 103
Coleman Benson 16.1 104 Ex: #5CSR20<cr> sets the maximum speed for servo #5 to 20rpm upon RESET (explained below).
Coleman Benson 1.1 105
Coleman Benson 16.1 106 After RESET: #5SR4<cr> sets the session's speed to 4rpm.
Coleman Benson 1.1 107
Coleman Benson 16.1 108 #5QSR<cr> would return *5QSR4<cr> which represents the value for that session.
Coleman Benson 1.1 109
Coleman Benson 16.1 110 #5QSR1<cr> would return *5QSR20<cr> which represents the value in EEPROM
RB1 56.1 111
Coleman Benson 65.2 112 == Virtual Angular Position ==
RB1 56.1 113
114 {In progress}
115
116 A "virtual position" is one which allows for multiple rotations of the output horn, moving the center position and more. The "absolute position" would be the angle of the output shaft with respect to 360.0 degrees.
117
118 [[image:LSS-servo-positions.jpg]]
119
120 Example: Gyre direction / rotation is positive (clockwise), and origin offset has not been modified. Each square represents 30 degrees.
121
122 #1D-300<cr> The servo is sent a command to move to -30.0 degrees (green arrow)
123
124 #1D2100<cr> This second position command is sent to the servo, which moves it to 210.0 degrees (orange arrow)
125
126 #1D-4200<cr> This next command rotates the servo counterclockwise to a position of -420 degrees (red arrow), which means one full rotation of 360 degrees,  stopping at an absolute position of 60.0 degrees (420.0-360.0), with a virtual position of -420.0 degrees.
127
128 Although the final physical position would be the same as if the servo were commanded to move to -60.0 degrees, the servo is in fact at -420.0 degrees.
129
130 #1D4800<cr> This new command is sent which would then cause the servo to rotate from -420.0 degrees to 480.0 degrees (blue arrow), which would be a total of 900 degrees of clockwise rotation, or 2.5 complete rotations.
131
132 #1D3300<cr> would cause the servo to rotate from 480.0 degrees to 330.0 degrees (yellow arrow).
133
134 If / once the servo loses power or is power cycled, it also loses the virtual position associated with that session. For example, if the virtual position was 480.0 degrees before power is cycled, upon power up the servo's position will be read as +120.0 degrees from zero (assuming center position has not been modified).
Coleman Benson 16.1 135 )))
Coleman Benson 1.1 136
137 = Command List =
138
139 |= #|=Description|= Action|= Query|= Config|= RC|= Serial|= Units|= Notes
Coleman Benson 75.1 140 | 1|[[**L**imp>>||anchor="H1.Limp28L29"]]| L| | | | ✓|none|
141 | 2|[[**H**alt & Hold>>||anchor="H2.Halt26Hold28H29"]]| H| | | | ✓|none|
142 | 3|[[**T**imed move>>||anchor="H3.Timedmove28T29"]]| T| | | | ✓|milliseconds| Modifier only (P, D, MD)
143 | 4|[[**S**peed>>||anchor="H4.Speed28S29"]]| S| | | | ✓|microseconds / second| Modifier only (P)
144 | 5|[[**M**ove in **D**egrees (relative)>>||anchor="H5.28Relative29MoveinDegrees28MD29"]]| MD| | | | ✓|tenths of degrees (ex 325 = 32.5 degrees; 91 = 9.1 degrees)|
145 | 6|[[**O**rigin Offset>>||anchor="H6.OriginOffsetAction28O29"]]| O| QO| CO| ✓| ✓|tenths of degrees (ex 325 = 32.5 degrees; 91 = 9.1 degrees)|
146 | 7|[[**A**ngular **R**ange>>||anchor="H7.AngularRange28AR29"]]| AR| QAR| CAR| ✓| ✓|tenths of degrees (ex 325 = 32.5 degrees; 91 = 9.1 degrees)|
147 | 8|[[Position in **P**ulse>>||anchor="H8.PositioninPulse28P29"]]| P| QP| | | ✓|microseconds|(((
Coleman Benson 28.1 148 See details below
RB1 10.1 149 )))
Coleman Benson 75.1 150 | 9|[[Position in **D**egrees>>||anchor="H9.PositioninDegrees28D29"]]| D| QD| | | ✓|tenths of degrees (ex 325 = 32.5 degrees; 91 = 9.1 degrees)|
151 | 10|[[**W**heel mode in **D**egrees>>||anchor="H10.WheelModeinDegrees28WD29"]]| WD| QWD| | | ✓|tenths of degrees per second (ex 248 = 24.8 degrees per second)|A.K.A. "Speed mode" or "Continuous rotation"
152 | 11|[[**W**heel mode in **R**PM>>||anchor="H11.WheelModeinRPM28WR29"]]| WR| QWR| | | ✓| rpm|A.K.A. "Speed mode" or "Continuous rotation"
153 | 12|[[Max **S**peed in **D**egrees>>||anchor="H12.SpeedinDegrees28SD29"]]| SD| QSD| CSD| ✓| ✓|tenths of degrees per second (ex 248 = 24.8 degrees per second)|QSD: Add modifier "2" for instantaneous speed
154 | 13|[[Max **S**peed in **R**PM>>||anchor="H13.SpeedinRPM28SR29"]]| SR| QSR| CSR| ✓| ✓|rpm|QSR: Add modifier "2" for instantaneous speed
RB1 64.30 155 | 14|[[**A**ngular **S**tiffness>>||anchor="H14.AngularStiffness28AS29"]]| AS| QAS| CAS| ✓| ✓|none|-4 to +4, but suggested values are between 0 to +4
156 | 15|[[**A**ngular **H**olding Stiffness>>||anchor="H15.AngularHoldStiffness28AH29"]]|AH|QAH|CAH| | ✓|none|-10 to +10, with default as 0.
157 |15b|[[**A**ngular **A**cceleration>>||anchor="H15b:AngularAcceleration28AA29"]]|AA|QAA|CAA| | ✓|degrees per second squared|Increments of 10 degrees per second squared
158 |15c|[[**A**ngular **D**eceleration>>||anchor="H15c:AngularDeceleration28AD29"]]|AD|QAD|CAD| | ✓|degrees per second squared|Increments of 10 degrees per second squared
RB1 70.1 159 |15d|[[**E**nable **M**otion control>>||anchor="H15d:MotionControl28MC29"]]|EM|QEM| | | ✓|none|EM0 to disable motion control, EM1 to enable. Session specific / does not survive power cycles
RB1 82.1 160 | 16|[[**LED** Color>>||anchor="H16.RGBLED28LED29"]]| LED| QLED| CLED| ✓| ✓|none (integer from 0 to 8)|0=Off (black); 1=Red 2=Green; 3=Blue; 4=Yellow; 5=Cyan; 6=Magenta; 7=White;
RB1 84.1 161 | 16b|[[**C**onfigure **L**ED **B**linking>>||anchor="H16b.ConfigureLEDBlinking28CLB29"]]| | | CLB| ✓| |none (integer from 0 to 63)|0=No blinking, Blink while: 1=Limp; 2=Holding 3=Accel; 4=Decel; 5=Free 6=Travel; 63=Always blink;
Coleman Benson 75.1 162 | 17|[[**ID** #>>||anchor="H17.IdentificationNumber"]]| | QID| CID| | ✓|none (integer from 0 to 250)|Note: ID 254 is a "broadcast" which all servos respond to
163 | 18|[[**B**aud rate>>||anchor="H18.BaudRate"]]| B| QB| CB| | ✓|none (integer)|
164 | 19|[[**G**yre direction (**G**)>>||anchor="H19.GyreRotationDirection"]]| G| QG| CG| ✓| ✓|none | Gyre / rotation direction where 1= CW (clockwise) -1 = CCW (counter-clockwise)
165 | 20|[[**F**irst Position (**P**ulse)>>||anchor="H20.First2InitialPosition28pulse29"]]| | QFP|CFP | ✓| ✓|none |
166 | 21|[[**F**irst Position (**D**egrees)>>||anchor="H21.First2InitialPosition28Degrees29"]]| | QFD|CFD| ✓| ✓|none |
167 | 22|[[**T**arget (**D**egree) **P**osition>>||anchor="H22.QueryTargetPositioninDegrees28QDT29"]]| | QDT| | | ✓|tenths of degrees (ex 325 = 32.5 degrees; 91 = 9.1 degrees)|
168 | 23|[[**M**odel **S**tring>>||anchor="H23.QueryModelString28QMS29"]]| | QMS| | | |none (string)| Recommended to determine the model|
169 | 23b|[[**M**odel>>||anchor="H23b.QueryModel28QM29"]]| | QM| | | |none (integer)| Returns a raw value representing the three model inputs (36 bit)|
170 | 24|[[Serial **N**umber>>||anchor="H24.QuerySerialNumber28QN29"]]| | QN| | | |none (integer)|
171 | 25|[[**F**irmware version>>||anchor="H25.QueryFirmware28QF29"]]| | QF| | | |none (integer)|
172 | 26|[[**Q**uery (general status)>>||anchor="H26.QueryStatus28Q29"]]| | Q| | | ✓|none (integer from 1 to 8)| See command description for details
173 | 27|[[**V**oltage>>||anchor="H27.QueryVoltage28QV29"]]| | QV| | | ✓|millivolts (ex 5936 = 5936mV = 5.936V)|
174 | 28|[[**T**emperature>>||anchor="H28.QueryTemperature28QT29"]]| | QT| | | ✓|tenths of degrees Celsius|Max temp before error: 85°C (servo goes limp)
175 | 29|[[**C**urrent>>||anchor="H29.QueryCurrent28QC29"]]| | QC| | | ✓|milliamps (ex 200 = 0.2A)|
RB1 64.30 176 | 30|[[**RC** Mode>>||anchor="H30.RCMode28CRC29"]]| | |CRC| |✓|none|(((
RB1 48.1 177 CRC: Add modifier "1" for RC-position mode.
178 CRC: Add modifier "2" for RC-wheel mode.
179 Any other value for the modifier results in staying in smart mode.
180 Puts the servo into RC mode. To revert to smart mode, use the button menu.
181 )))
RB1 64.30 182 |31|[[**RESET**>>||anchor="H31.RESET"]]| | | | | ✓|none|Soft reset. See command for details.
RB1 65.1 183 |32|[[**DEFAULT**>>||anchor="H32.DEFAULTA026CONFIRM"]]| | | | |✓|none|Revert to firmware default values. See command for details
184 |33|[[**UPDATE**>>||anchor="H33.UPDATEA026CONFIRM"]]| | | | |✓|none|Update firmware. See command for details.
Coleman Benson 1.1 185
RB1 64.3 186 == Details ==
Coleman Benson 1.1 187
RB1 64.15 188 ====== __1. Limp (**L**)__ ======
Coleman Benson 1.1 189
190 Example: #5L<cr>
191
192 This action causes the servo to go "limp". The microcontroller will still be powered, but the motor will not. As an emergency safety feature, should the robot not be doing what it is supposed to or risks damage, use the broadcast ID to set all servos limp #254L<cr>.
193
RB1 64.16 194 ====== __2. Halt & Hold (**H**)__ ======
Coleman Benson 1.1 195
196 Example: #5H<cr>
197
198 This action overrides whatever the servo might be doing at the time the command is received (accelerating, moving continuously etc.) and causes it to stop immediately and hold that position.
199
RB1 64.16 200 ====== __3. Timed move (**T**)__ ======
Coleman Benson 1.1 201
202 Example: #5P1500T2500<cr>
203
204 Timed move can be used only as a modifier for a position (P) action. The units are in milliseconds, so a timed move of 2500 milliseconds would cause the servo to rotate from its current position to the desired position in 2.5 seconds. This command is in place to ensure backwards compatibility with the SSC-32 / 32U protocol.
205
Coleman Benson 72.1 206 Note: If the calculated speed at which a servo must rotate for a timed move is greater than its maximum speed (which depends on voltage and load), then it will move at its maximum speed, and the time of the move may be longer than requested.
207
RB1 64.28 208 ====== __4. Speed (**S**)__ ======
Coleman Benson 1.1 209
210 Example: #5P1500S750<cr>
211
212 This command is a modifier only for a position (P) action and determines the speed of the move in microseconds per second. A speed of 750 microseconds would cause the servo to rotate from its current position to the desired position at a speed of 750 microseconds per second. This command is in place to ensure backwards compatibility with the SSC-32 / 32U protocol.
213
RB1 64.16 214 ====== __5. (Relative) Move in Degrees (**MD**)__ ======
Coleman Benson 1.1 215
216 Example: #5MD123<cr>
217
218 The relative move command causes the servo to read its current position and move the specified number of tenths of degrees in the corresponding position. For example if the servo is set to rotate CW (default) and an MD command of 123 is sent to the servo, it will cause the servo to rotate clockwise by 12.3 degrees. Negative commands would cause the servo to rotate in the opposite configured direction.
219
RB1 64.16 220 ====== __6. Origin Offset Action (**O**)__ ======
Coleman Benson 1.1 221
222 Example: #5O2400<cr>
223
224 This command allows you to temporarily change the origin of the servo in relation to the factory zero position. The setting will be lost upon servo reset / power cycle. Origin offset commands are not cumulative and always relate to factory zero. Note that for a given session, the O command overrides the CO command. In the first image, the origin at factory offset '0' (centered).
225
226 [[image:LSS-servo-default.jpg]]
227
228 In the second image, the origina, as well as the angular range (explained below) have been shifted by 240.0 degrees:
229
230 [[image:LSS-servo-origin.jpg]]
231
232 Origin Offset Query (**QO**)
233
234 Example: #5QO<cr> Returns: *5QO-13
235
236 This allows you to query the angle (in tenths of degrees) of the origin in relation to the factory zero position.
237
238 Configure Origin Offset (**CO**)
239
240 Example: #5CO-24<cr>
241
242 This command allows you to change the origin of the servo in relation to the factory zero position in EEPROM. The setting will be saved upon servo reset / power cycle. Origin offset configuration commands are not cumulative and always relate to factory zero. The new origin is also used in RC mode.
243
RB1 64.16 244 ====== __7. Angular Range (**AR**)__ ======
Coleman Benson 1.1 245
246 Example: #5AR1800<cr>
247
248 This command allows you to temporarily change the total angular range of the servo in tenths of degrees. This applies to the Position in Pulse (P) command and RC mode. The default for (P) and RC mode is 1800 (180.0 degrees total, or ±90.0 degrees). In the first image,
249
250 [[image:LSS-servo-default.jpg]]
251
252 Here, the angular range has been restricted to 180.0 degrees, or -90.0 to +90.0. The center has remained unchanged.
253
254 [[image:LSS-servo-ar.jpg]]
255
256 The angular range action command (ex. #5AR1800<cr>) and origin offset action command (ex. #5O-1200<cr>) an be used to move both the center and limit the angular range:
257
258 [[image:LSS-servo-ar-o-1.jpg]]
259
260 Query Angular Range (**QAR**)
261
262 Example: #5QAR<cr> might return *5AR2756
263
264 Configure Angular Range (**CAR**)
265
266 This command allows you to change the total angular range of the servo in tenths of degrees in EEPROM. The setting will be saved upon servo reset / power cycle.
267
RB1 64.16 268 ====== __8. Position in Pulse (**P**)__ ======
Coleman Benson 1.1 269
270 Example: #5P2334<cr>
271
Coleman Benson 11.1 272 The position in PWM pulses was retained in order to be backward compatible with the SSC-32 / 32U protocol. This relates the desired angle with an RC standard PWM pulse and is further explained in the SSC-32 and SSC-32U manuals found on Lynxmotion.com. Without any modifications to configuration considered, and a ±90.0 degrees standard range where 1500 microseconds is centered, a pulse of 2334 would set the servo to 165.1 degrees. Valid values for P are [500, 2500]. Values outside this range are corrected to end points.
Coleman Benson 1.1 273
274 Query Position in Pulse (**QP**)
275
Coleman Benson 37.1 276 Example: #5QP<cr> might return *5QP2334
Coleman Benson 1.1 277
Coleman Benson 11.1 278 This command queries the current angular position in PWM "units". The user must take into consideration that the response includes any angular range and origin configurations in order to determine the actual angle. 
Coleman Benson 37.1 279 Valid values for QP are {-500, [500, 2500], -2500}. Values outside the [500, 2500] range are given a negative corresponding end point value to indicate they are out of bounds (note that if the servo is physically located at one of the endpoints, it may return a negative number if it is a fraction of a degree beyond the position).
Coleman Benson 1.1 280
RB1 64.16 281 ====== __9. Position in Degrees (**D**)__ ======
Coleman Benson 1.1 282
283 Example: #5PD1456<cr>
284
285 This moves the servo to an angle of 145.6 degrees, where the center (0) position is centered. Negative values (ex. -176 representing -17.6 degrees) are used. A full circle would be from -1800 to 1800 degrees. A value of 2700 would be the same angle as -900, except the servo would move in a different direction.
286
287 Larger values are permitted and allow for multi-turn functionality using the concept of virtual position.
288
289 Query Position in Degrees (**QD**)
290
Coleman Benson 37.1 291 Example: #5QD<cr> might return *5QD132<cr>
Coleman Benson 1.1 292
Coleman Benson 37.1 293 This means the servo is located at 13.2 degrees.
294
RB1 64.16 295 ====== __10. Wheel Mode in Degrees (**WD**)__ ======
Coleman Benson 1.1 296
297 Ex: #5WD900<cr>
298
299 This command sets the servo to wheel mode where it will rotate in the desired direction at the selected speed. The example above would have the servo rotate at 90.0 degrees per second clockwise (assuming factory default configurations).
300
301 Query Wheel Mode in Degrees (**QWD**)
302
303 Ex: #5QWD<cr> might return *5QWD900<cr>
304
305 The servo replies with the angular speed in tenths of degrees per second. A negative sign would indicate the opposite direction (for factory default a negative value would be counter clockwise).
306
RB1 64.16 307 ====== __11. Wheel Mode in RPM (**WR**)__ ======
Coleman Benson 1.1 308
309 Ex: #5WR40<cr>
310
311 This command sets the servo to wheel mode where it will rotate in the desired direction at the selected rpm. Wheel mode (a.k.a. "continuous rotation") has the servo operate like a geared DC motor. The servo's maximum rpm cannot be set higher than its physical limit at a given voltage. The example above would have the servo rotate at 40 rpm clockwise (assuming factory default configurations).
312
313 Query Wheel Mode in RPM (**QWR**)
314
315 Ex: #5QWR<cr> might return *5QWR40<cr>
316
317 The servo replies with the angular speed in rpm. A negative sign would indicate the opposite direction (for factory default a negative value would be counter clockwise).
318
RB1 64.16 319 ====== __12. Speed in Degrees (**SD**)__ ======
Coleman Benson 1.1 320
321 Ex: #5SD1800<cr>
322
323 This command sets the servo's maximum speed for action commands in tenths of degrees per second for that session. In the example above, the servo's maximum speed for that session would be set to 180.0 degrees per second. Therefore maximum speed for actions can be set "on the fly". The servo's maximum speed cannot be set higher than its physical limit at a given voltage. SD overrides CSD (described below) for that session. Upon reset or power cycle, the servo reverts to the value associated with CSD as described below. Note that SD and SR (described below) are effectively the same, but allow the user to specify the speed in either unit. The last command (either SR or SD) is what the servo uses for that session.
324
325 Query Speed in Degrees (**QSD**)
326
327 Ex: #5QSD<cr> might return *5QSD1800<cr>
328
RB1 25.1 329 By default QSD will return the current session value, which is set to the value of CSD as reset/power cycle and changed whenever a SD/SR command is processed.
RB1 23.1 330 If #5QSD1<cr> is sent, the configured maximum speed (CSD value) will be returned instead. You can also query the current speed using "2" and the current target travel speed using "3". See the table below for an example:
Coleman Benson 1.1 331
RB1 24.1 332 |**Command sent**|**Returned value (1/10 °)**
Coleman Benson 32.1 333 |ex: #5QSD<cr>|Session value for maximum speed (set by latest SD/SR command)
334 |ex: #5QSD1<cr>|Configured maximum speed  (set by CSD/CSR)
335 |ex: #5QSD2<cr>|Instantaneous speed (same as QWD)
336 |ex: #5QSD3<cr>|Target travel speed
RB1 23.1 337
Coleman Benson 1.1 338 Configure Speed in Degrees (**CSD**)
339
340 Ex: #5CSD1800<cr>
341
342 Using the CSD command sets the servo's maximum speed which is saved in EEPROM. In the example above, the servo's maximum speed will be set to 180.0 degrees per second. When the servo is powered on (or after a reset), the CSD value is used. Note that CSD and CSR (described below) are effectively the same, but allow the user to specify the speed in either unit. The last command (either CSR or CSD) is what the servo uses for that session.
343
RB1 64.16 344 ====== __13. Speed in RPM (**SR**)__ ======
Coleman Benson 1.1 345
346 Ex: #5SD45<cr>
347
348 This command sets the servo's maximum speed for action commands in rpm for that session. In the example above, the servo's maximum speed for that session would be set to 45rpm. Therefore maximum speed for actions can be set "on the fly". The servo's maximum speed cannot be set higher than its physical limit at a given voltage. SD overrides CSD (described below) for that session. Upon reset or power cycle, the servo reverts to the value associated with CSD as described below. Note that SD (described above) and SR are effectively the same, but allow the user to specify the speed in either unit. The last command (either SR or SD) is what the servo uses for that session.
349
350 Query Speed in Degrees (**QSR**)
351
352 Ex: #5QSR<cr> might return *5QSR45<cr>
353
RB1 25.1 354 By default QSR will return the current session value, which is set to the value of CSR as reset/power cycle and changed whenever a SD/SR command is processed.
355 If #5QSR1<cr> is sent, the configured maximum speed (CSR value) will be returned instead. You can also query the current speed using "2" and the current target travel speed using "3". See the table below for an example:
Coleman Benson 1.1 356
RB1 25.1 357 |**Command sent**|**Returned value (1/10 °)**
Coleman Benson 32.1 358 |ex: #5QSR<cr>|Session value for maximum speed (set by latest SD/SR command)
359 |ex: #5QSR1<cr>|Configured maximum speed  (set by CSD/CSR)
360 |ex: #5QSR2<cr>|Instantaneous speed (same as QWR)
361 |ex: #5QSR3<cr>|Target travel speed
Coleman Benson 1.1 362
RB1 25.1 363 Configure Speed in RPM (**CSR**)
364
Coleman Benson 1.1 365 Ex: #5CSR45<cr>
366
RB1 25.1 367 Using the CSR command sets the servo's maximum speed which is saved in EEPROM. In the example above, the servo's maximum speed will be set to 45rpm. When the servo is powered on (or after a reset), the CSR value is used. Note that CSD and CSR are effectively the same, but allow the user to specify the speed in either unit. The last command (either CSR or CSD) is what the servo uses for that session.
Coleman Benson 1.1 368
RB1 64.16 369 ====== __14. Angular Stiffness (**AS**)__ ======
Coleman Benson 15.1 370
Coleman Benson 31.1 371 The servo's rigidity / angular stiffness can be thought of as (though not identical to) a damped spring in which the value affects the stiffness and embodies how much, and how quickly the servo tried keep the requested position against changes.
Coleman Benson 15.1 372
Coleman Benson 31.1 373 A positive value of "angular stiffness":
Coleman Benson 15.1 374
375 * The more torque will be applied to try to keep the desired position against external input / changes
376 * The faster the motor will reach its intended travel speed and the motor will decelerate faster and nearer to its target position
377
378 A negative value on the other hand:
379
380 * Causes a slower acceleration to the travel speed, and a slower deceleration
381 * Allows the target position to deviate more from its position before additional torque is applied to bring it back
382
383 The default value is zero and the effect becomes extreme by -4, +4. There are no units, only integers between -4 to 4. Greater values produce increasingly erratic behavior.
384
Coleman Benson 31.1 385 Ex: #5AS-2<cr>
Coleman Benson 15.1 386
Coleman Benson 31.1 387 This reduces the angular stiffness to -2 for that session, allowing the servo to deviate more around the desired position. This can be beneficial in many situations such as impacts (legged robots) where more of a "spring" effect is desired. Upon reset, the servo will use the value stored in memory, based on the last configuration command.
Coleman Benson 15.1 388
Coleman Benson 31.1 389 Ex: #5QAS<cr>
Coleman Benson 15.1 390
391 Queries the value being used.
392
Coleman Benson 31.1 393 Ex: #5CAS<cr>
Coleman Benson 15.1 394
Coleman Benson 31.1 395 Writes the desired angular stiffness value to memory.
Coleman Benson 15.1 396
RB1 64.16 397 ====== __15. Angular Hold Stiffness (**AH**)__ ======
Coleman Benson 15.1 398
Coleman Benson 62.1 399 The angular holding stiffness determines the servo's ability to hold a desired position under load. Values can be from -10 to 10, with the default being 0. Note that negative values mean the final position can be easily deflected.
Coleman Benson 15.1 400
Coleman Benson 62.1 401 Ex: #5AH3<cr>
402
403 This sets the holding stiffness for servo #5 to 3 for that session.
404
405 Query Angular Hold Stiffness (**QAH**)
406
407 Ex: #5QAH<cr> might return *5QAH3<cr>
408
409 This returns the servo's angular holding stiffness value.
410
Coleman Benson 63.1 411 Configure Angular Hold Stiffness (**CAH**)
Coleman Benson 62.1 412
413 Ex: #5CAH2<cr>
414
415 This writes the angular holding stiffness of servo #5 to 2 to EEPROM
416
RB1 64.16 417 ====== __15b: Angular Acceleration (**AA**)__ ======
Coleman Benson 63.1 418
419 {More details to come}
420
RB1 64.16 421 ====== __15c: Angular Deceleration (**AD**)__ ======
Coleman Benson 63.1 422
423 {More details to come}
424
RB1 71.1 425 ====== __15d: Motion Control (**EM**)__ ======
Coleman Benson 63.1 426
427 {More details to come}
428
RB1 64.16 429 ====== __16. RGB LED (**LED**)__ ======
Coleman Benson 1.1 430
431 Ex: #5LED3<cr>
432
433 This action sets the servo's RGB LED color for that session.The LED can be used for aesthetics, or (based on user code) to provide visual status updates. Using timing can create patterns.
434
Coleman Benson 9.1 435 0=OFF 1=RED 2=GREEN 3= BLUE 4=YELLOW 5=CYAN 6= 7=MAGENTA, 8=WHITE 
Coleman Benson 1.1 436
437 Query LED Color (**QLED**)
438
439 Ex: #5QLED<cr> might return *5QLED5<cr>
440
441 This simple query returns the indicated servo's LED color.
442
443 Configure LED Color (**CLED**)
444
Coleman Benson 35.1 445 Configuring the LED color via the CLED command sets the startup color of the servo after a reset or power cycle. Note that it also changes the session's LED color immediately as well.
Coleman Benson 1.1 446
RB1 83.1 447 ====== __16b. Configure LED Blinking (**CLB**)__ ======
448
RB1 85.1 449 This command allows you to control when the RGB LED will blink the user set color (see [[H16b.RGBLED28LED29]]) for details).
450 You can turn on or off blinking for various LSS status. Here is the list and their associated value: 0=No blinking, Blink while: 1=Limp; 2=Holding 4=Accel; 8=Decel; 16=Free 32=Travel; 63=Always blink;
RB1 83.1 451
RB1 85.1 452 To set blinking, use CLB with the value of your choosing. To activate blinking in multiple status, simply add together the values of the corresponding status. See examples below:
453
454 Ex: #5CLB0<cr> to turn off all blinking (LED always solid)
455 Ex: #5CLB1<cr> only blink when limp
456 Ex: #5CLB2<cr> only blink when holding
457 Ex: #5CLB12<cr> only blink when accel or decel
458 Ex: #5CLB48<cr> only blink when free or travel
459 Ex: #5CLB63<cr> blink in all status
460
RB1 64.16 461 ====== __17. Identification Number__ ======
Coleman Benson 1.1 462
RB1 17.1 463 A servo's identification number cannot be set "on the fly" and must be configured via the CID command described below. The factory default ID number for all servos is 0. Since smart servos are intended to be daisy chained, in order to respond differently from one another, the user must set different identification numbers. Servos with the same ID and baud rate will all receive and react to the same commands.
Coleman Benson 1.1 464
465 Query Identification (**QID**)
466
Coleman Benson 38.1 467 EX: #254QID<cr> might return *QID5<cr>
Coleman Benson 1.1 468
Coleman Benson 38.1 469 When using the query ID command, it is best to only have one servo connected and thus receive only one reply using the broadcast command (ID 254). Alternatively, pushing the button upon startup and temporarily setting the servo ID to 255 will still result in the servo responding with its "real" ID.
Coleman Benson 1.1 470
471 Configure ID (**CID**)
472
Coleman Benson 38.1 473 Ex: #4CID5<cr>
Coleman Benson 1.1 474
475 Setting a servo's ID in EEPROM is done via the CID command. All servos connected to the same serial bus will be assigned that ID. In most situations each servo must be set a unique ID, which means each servo must be connected individually to the serial bus and receive a unique CID number. It is best to do this before the servos are added to an assembly. Numbered stickers are provided to distinguish each servo after their ID is set, though you are free to use whatever alternative method you like.
476
RB1 64.16 477 ====== __18. Baud Rate__ ======
Coleman Benson 1.1 478
RB1 20.1 479 A servo's baud rate cannot be set "on the fly" and must be configured via the CB command described below. The factory default baud rate for all servos is 9600. Since smart servos are intended to be daisy chained, in order to respond to the same serial bus, all servos in that project should ideally be set to the same baud rate. Setting different baud rates will have the servos respond differently and may create issues. Available baud rates are: 9.6 kbps, 19.2 kbps, 38.4 kbps, 57.6 kbps, 115.2 kbps, 230.4 kbps, 250.0 kbps, 460.8 kbps, 500.0 kbps, 750.0 kbps*, 921.6 kbps*. Servos are shipped with a baud rate set to 9600. The baud rates are currently restricted to those above.
RB1 22.1 480 \*: Current tests reveal baud rates above 500 kbps are unstable and can cause timeouts. Please keep this in mind if using those / testing them out.
Coleman Benson 1.1 481
482 Query Baud Rate (**QB**)
483
484 Ex: #5QB<cr> might return *5QB9600<cr>
485
486 Querying the baud rate is used simply to confirm the CB configuration command before the servo is power cycled.
487
488 Configure Baud Rate (**CB**)
489
490 Ex: #5CB9600<cr>
491
492 Sending this command will change the baud rate associated with servo ID 5 to 9600 bits per second.
493
RB1 64.16 494 ====== __19. Gyre Rotation Direction__ ======
Coleman Benson 1.1 495
496 "Gyre" is defined as a circular course or motion. The effect of changing the gyre direction is as if you were to use a mirror image of a circle. CW = 1; CCW = -1. The factory default is clockwise (CW).
497
498 {images showing before and after with AR and Origin offset}
499
500 Query Gyre Direction (**QG**)
501
502 Ex: #5QG<cr> might return *5QG-1<cr>
503
504 The value returned above means the servo is in a counter-clockwise gyration.
505
506 Configure Gyre (**CG**)
507
508 Ex: #5CG-1<cr>
509
510 This changes the gyre direction as described above and also writes to EEPROM.
511
RB1 64.16 512 ====== __20. First / Initial Position (pulse)__ ======
Coleman Benson 1.1 513
RB1 49.1 514 In certain cases, a user might want to have the servo move to a specific angle upon power up. We refer to this as "first position". The factory default has no first position value stored in EEPROM and therefore upon power up, the servo remains limp until a position (or hold command) is assigned. FP and FD are different in that FP is used for RC mode only, whereas FD is used for smart mode only.
Coleman Benson 1.1 515
516 Query First Position in Pulses (**QFP**)
517
518 Ex: #5QFP<cr> might return *5QFP1550<cr>
519
Coleman Benson 36.1 520 The reply above indicates that servo with ID 5 has a first position pulse of 1550 microseconds. If no first position has been set, servo will respond with DIS ("disabled").
Coleman Benson 1.1 521
Coleman Benson 36.1 522 Configure First Position in Pulses (**CFP**)
Coleman Benson 1.1 523
524 Ex: #5CP1550<cr>
525
Coleman Benson 36.1 526 This configuration command means the servo, when set to RC mode, will immediately move to an angle equivalent to having received an RC pulse of 1550 microseconds upon power up. Sending a CFP command without a number results in the servo remaining limp upon power up (i.e. disabled).
Coleman Benson 1.1 527
RB1 64.16 528 ====== __21. First / Initial Position (Degrees)__ ======
Coleman Benson 1.1 529
RB1 49.1 530 In certain cases, a user might want to have the servo move to a specific angle upon power up. We refer to this as "first position". The factory default has no first position value stored in EEPROM and therefore upon power up, the servo remains limp until a position (or hold command) is assigned. FP and FD are different in that FP is used for RC mode only, whereas FD is used for smart mode only.
Coleman Benson 1.1 531
532 Query First Position in Degrees (**QFD**)
533
534 Ex: #5QFD<cr> might return *5QFD64<cr>
535
536 The reply above indicates that servo with ID 5 has a first position pulse of 1550 microseconds.
537
538 Configure First Position in Degrees (**CFD**)
539
540 Ex: #5CD64<cr>
541
RB1 49.1 542 This configuration command means the servo, when set to smart mode, will immediately move to 6.4 degrees upon power up. Sending a CFD command without a number results in the servo remaining limp upon power up.
Coleman Benson 1.1 543
RB1 64.16 544 ====== __22. Query Target Position in Degrees (**QDT**)__ ======
Coleman Benson 1.1 545
546 Ex: #5QDT<cr> might return *5QDT6783<cr>
547
548 The query target position command returns the target angle during and after an action which results in a rotation of the servo horn. In the example above, the servo is rotating to a virtual position of 678.3 degrees. Should the servo not have a target position or be in wheel mode, it will respond without a number (Ex: *5QDT<cr>).
549
RB1 64.16 550 ====== __23. Query Model String (**QMS**)__ ======
Coleman Benson 1.1 551
RB1 64.1 552 Ex: #5QMS<cr> might return *5QMSLSS-HS1cr>
Coleman Benson 1.1 553
RB1 64.1 554 This reply means the servo model is LSS-HS1, meaning a high speed servo, first revision.
Coleman Benson 1.1 555
RB1 64.16 556 ====== __23b. Query Model (**QM**)__ ======
RB1 64.1 557
558 Ex: #5QM<cr> might return *5QM68702699520cr>
559
560 This reply means the servo model is 0xFFF000000 or 100, meaning a high speed servo, first revision.
561
RB1 64.16 562 ====== __24. Query Serial Number (**QN**)__ ======
Coleman Benson 1.1 563
564 Ex: #5QN<cr> might return *5QN~_~_<cr>
565
566 The number in the response is the servo's serial number which is set and cannot be changed.
567
RB1 64.16 568 ====== __25. Query Firmware (**QF**)__ ======
Coleman Benson 1.1 569
570 Ex: #5QF<cr> might return *5QF11<cr>
571
572 The integer in the reply represents the firmware version with one decimal, in this example being 1.1
573
RB1 64.16 574 ====== __26. Query Status (**Q**)__ ======
Coleman Benson 1.1 575
RB1 34.1 576 Ex: #5Q<cr> might return *5Q6<cr>, which indicates the motor is holding a position.
Coleman Benson 1.1 577
Coleman Benson 35.1 578 |*Value returned|**Status**|**Detailed description**
RB1 34.1 579 |ex: *5Q0<cr>|Unknown|LSS is unsure
580 |ex: *5Q1<cr>|Limp|Motor driving circuit is not powered and horn can be moved freely
581 |ex: *5Q2<cr>|Free moving|Motor driving circuit is not powered and horn can be moved freely
582 |ex: *5Q3<cr>|Accelerating|Increasing speed from rest (or previous speeD) towards travel speed
583 |ex: *5Q4<cr>|Traveling|Moving at a stable speed
Coleman Benson 69.1 584 |ex: *5Q5<cr>|Decelerating|Decreasing from travel speed towards final position.
RB1 34.1 585 |ex: *5Q6<cr>|Holding|Keeping current position
586 |ex: *5Q7<cr>|Stepping|Special low speed mode to maintain torque
Coleman Benson 69.1 587 |ex: *5Q8<cr>|Outside limits|{More details coming soon}
RB1 34.1 588 |ex: *5Q9<cr>|Stuck|Motor cannot perform request movement at current speed setting
Coleman Benson 69.1 589 |ex: *5Q10<cr>|Blocked|Similar to stuck, but the motor is at maximum duty and still cannot move (i.e.: stalled)
Coleman Benson 1.1 590
RB1 64.16 591 ====== __27. Query Voltage (**QV**)__ ======
Coleman Benson 1.1 592
Coleman Benson 59.1 593 Ex: #5QV<cr> might return *5QV11200<cr>
Coleman Benson 1.1 594
595 The number returned has one decimal, so in the case above, servo with ID 5 has an input voltage of 11.2V (perhaps a three cell LiPo battery).
596
RB1 64.16 597 ====== __28. Query Temperature (**QT**)__ ======
Coleman Benson 1.1 598
599 Ex: #5QT<cr> might return *5QT564<cr>
600
601 The units are in tenths of degrees Celcius, so in the example above, the servo's internal temperature is 56.4 degrees C. To convert from degrees Celcius to degrees Farenheit, multiply by 1.8 and add 32. Therefore 56.4C = 133.52F.
602
RB1 64.16 603 ====== __29. Query Current (**QC**)__ ======
Coleman Benson 1.1 604
605 Ex: #5QC<cr> might return *5QC140<cr>
606
607 The units are in milliamps, so in the example above, the servo is consuming 140mA, or 0.14A.
608
RB1 64.16 609 ====== __30. RC Mode (**CRC**)__ ======
Coleman Benson 42.1 610
RB1 51.1 611 This command puts the servo into RC mode (position or continuous), where it will only respond to RC pulses. Note that because this is the case, the servo will no longer accept serial commands. The servo can be placed back into smart mode by using the button menu.
Coleman Benson 42.1 612
RB1 50.1 613 |**Command sent**|**Note**
614 |ex: #5CRC<cr>|Stay in smart mode.
615 |ex: #5CRC1<cr>|Change to RC position mode.
616 |ex: #5CRC2<cr>|Change to RC continuous (wheel) mode.
RB1 52.2 617 |ex: #5CRC*<cr>|Where * is any number or value. Stay in smart mode.
RB1 50.1 618
Coleman Benson 42.1 619 EX: #5CRC<cr>
620
RB1 64.16 621 ====== __31. RESET__ ======
Coleman Benson 1.1 622
623 Ex: #5RESET<cr> or #5RS<cr>
624
625 This command does a "soft reset" (no power cycle required) and reverts all commands to those stored in EEPROM (i.e. configuration commands).
626
RB1 64.16 627 ====== __32. DEFAULT & CONFIRM__ ======
Coleman Benson 1.1 628
629 Ex: #5DEFAULT<cr>
630
Coleman Benson 12.1 631 This command sets in motion the reset all values to the default values included with the version of the firmware installed on that servo. The servo then waits for the CONFIRM command. Any other command received will cause the servo to exit the DEFAULT function.
Coleman Benson 1.1 632
Coleman Benson 12.1 633 EX: #5DEFAULT<cr> followed by #5CONFIRM<cr>
Coleman Benson 1.1 634
Coleman Benson 12.1 635 Since it it not common to have to restore all configurations, a confirmation command is needed after a firmware command is sent. Should any command other than CONFIRM be received by the servo after the firmware command has been received, it will leave the firmware action.
Coleman Benson 1.1 636
Coleman Benson 13.1 637 Note that after the CONFIRM command is sent, the servo will automatically perform a RESET.
638
RB1 64.16 639 ====== __33. UPDATE & CONFIRM__ ======
Coleman Benson 1.1 640
Coleman Benson 12.1 641 Ex: #5UPDATE<cr>
Coleman Benson 1.1 642
Coleman Benson 12.1 643 This command sets in motion the equivalent of a long button press when the servo is not powered in order to enter firmware update mode. This is useful should the button be broken or inaccessible. The servo then waits for the CONFIRM command. Any other command received will cause the servo to exit the UPDATE function.
Coleman Benson 1.1 644
Coleman Benson 12.1 645 EX: #5UPDATE<cr> followed by #5CONFIRM<cr>
Coleman Benson 1.1 646
Coleman Benson 12.1 647 Since it it not common to have to update firmware, a confirmation command is needed after an UPDATE command is sent. Should any command other than CONFIRM be received by the servo after the firmware command has been received, it will leave the firmware action.
648
Coleman Benson 13.1 649 Note that after the CONFIRM command is sent, the servo will automatically perform a RESET.
Copyright RobotShop 2018