LSS FlowArm

Version 30.1 by Coleman Benson on 2019/09/09 09:58

LSS-FlowArm.png

wiki-download.png

Page Contents

Description

{Coming soon}

The LSS FlowArm application was created using FlowBotics Studio software and is intended to allow easy control of the standard configuration Lynxmotion Servo Erector Set (S.E.S.) v2 articulated robotic arm. The graphical interface shows a side and top view of the arm, as well as the gripper and wrist. The full-featured built-in sequencer allows you create sequences which have the arm move automatically from one position ("frame") to the next. 

Features

  • Graphical interface for the Lynxmotion SES V2 articulated robot arm
  • Full featured sequencer allows recording and playback of many sequences via keyboard input
  • Teach mode allows the user to move the arm and have the virtual arm follow
  • Position the arm using rectangular or cylindrical coordinates, virtual joysticks or mouse drag
  • Application can be modified via FlowBotics Studio

Initial Setup

In order to understand the features, functionality and nuances of the Lynxmotion smart servos, it is suggested to read through the lynxmotion-smart-servo section of the wiki.

Servo IDs

Before assembling the arm, each of the IDs assigned to the servos must correspond with what is needed in the software.

  • Base: 1
  • Shoulder: 2
  • Elbow: 3
  • Wrist: 4
  • Gripper: 5

To do so, the LSS Configuration Software is used. Connect each servo to the LSS Adapter, ensuring the wall adapter and USB cable are connected, and the three-way switch is set to USB. Using the softwar 

Interface

Header

lss-flowarm-header.jpg

STORE OFFSETS

Press the "Store offsets" button to change the all of the servo offsets (this makes use of the CO command as part of the LSS Communication Protocol).

LIMP

Causes all servos to go LIMP (i.e. lose torque). The arm will collapse.

STOP

Causes all servos to stop their motion and hold their position.

TEACH

Teach mode allows a user to physically move the arm to a designed location

In order to ensure the arm does not collapse, pressing the TEACH button will start a 5 second countdown during which the arm will slowly lose torque (angular force) until all servos are limp.

When in teach mode, an orange outline appears over all on-screen fields which would cause a conflict and therefore cannot be used. 

CAREFUL: Do not move the servos too quickly. We suggest moving the gripper servo, or temporarily removing the aesthetic shell.

Once the arm is limp, it can be moved physically, and the application will regularly read the physical position of each of the servos and move the virtual arm on screen to match.

Use the sequencer to save each position (frame). Intermediate frames can be added as needed. For more information on the sequencer, refer to the sequencer section below.

GRID / Units

Units can be toggled between Metric or Imperial

BAUD

The baud rate suggested is 9600, though other (standard) baud rates can be used.

COM

This field selects which of your computer's COM ports is connected to the LSS Adapter, which is provided with the standard SES v2 articulated robot arm. Be sure to select the appropriate COM port to which the LSS adapter is connected. If you are unsure, go to Device Manager in Windows, and view the list of USB devices connected. The LSS Adapter uses an FTDI USB to serial chip.

When the software is opened, a scan of all COM ports is done automatically and list of all available COM ports will be found in the drop down menu, along with OFF (stop searching for a COM port), and AUTO (the application tries to automatically find the correct COM port by sending a query command at the corresponding BAUD rate). 

If the red and green lights next to the field are flashing, the correct COM port has not yet been found, and the user may need to manually select the correct CIM port.

If the red light is solid, then no correct COM port has been located.

If the green light is solid, the a COM port has been located.

Window Size

lss-flowarm-size.jpg

A the top right of the window, there are three dark rectangles representing the window size.

2D Views & Grid

Arm Configuration

The arm shown on screen is based on the assembly guide. BETA testers have been encouraged to use the 3:1 gear ratio in the shoulder and as such should have toggled switch 1 in the header.

The aesthetics of the arms will be changing for the final / release version of the LSS Flowarm software.

Side View

lss-flowarm-side-view.jpg

The left view is a representation {more to come|

Top View

lss-flowarm-top-view.jpg

The top view shows the arm {more to come}

Left Menu

Gripper

lss-flowarm-gripper-view.jpg

The gripper and wrist rotate can be controlled from this menu

Wrist

lss-flowarm-wrist-view.jpg

End Effector Position

lss-flowarm-positioning.jpg

The position of the end effector can be controlled either by manually entering the information for R (radius), or x,y,z coordinate, or using the arrows.

Data Log

lss-flowarm-data-log.jpg

The console will be used as a serial command interface to manually send commands to the bus.

Sequencer

lss-flowarm-sequencer.jpg

The sequencer allows the user to record sequences. From left to right:

Sequence association

{Work in progress}

lss-flowarm-keyboard-liveupdate.jpg

Downloads

Download LSS Flowarm 3.0.8.12 here.

Password: beta

BETA: Note that information described here is subject to change, and is available for BETA testers.

{Work in progress}

Tags:
Created by Eric Nantel on 2019/03/22 07:09
Copyright RobotShop 2018