Wiki source code of LSS-HUB Board

Last modified by Eric Nantel on 2023/03/15 07:59

Hide last authors
Eric Nantel 101.1 1 {{lightbox image="LSS-HUB.png" width="350"/}}
2
Eric Nantel 108.1 3 [[[[image:[email protected]||alt="buy-online.jpg"]]>>https://www.robotshop.com/products/lynxmotion-lss-power-hub||rel="noopener noreferrer" target="_blank"]]
Eric Nantel 93.1 4
Eric Nantel 97.1 5 **Table of Contents**
Eric Nantel 21.1 6
Eric Nantel 30.1 7 {{toc/}}
Eric Nantel 29.1 8
Coleman Benson 1.1 9 = Description =
10
Brahim Daouas 74.2 11 The LSS Power Hub provides a simple solution to supply power to and communicate with the smart servos. It is also a useful tool to split the LSS bus from one servo to two or three while allowing these servos to be powered separately. The Power Hub can be mounted directly to the servos.
Coleman Benson 1.1 12
13 = Features =
14
Coleman Benson 74.1 15 * 4x LSS connectors of which three can be powered separately by removing the onboard Vin jumper.
Coleman Benson 16.1 16 * 2.1mm x 5.5mm center positive female barrel jack
Brahim Daouas 77.5 17 * 2.54mm spaced Tx, Rx, Vin and GND pins broken out to allow control of the LSS motors using an external UART serial device
Coleman Benson 87.1 18 * LSS motor mounting
Coleman Benson 1.1 19
20 (((
21 = Specifications =
22 )))
23
Coleman Benson 88.1 24 * 3A (amps) maximum current per LSS connector
Coleman Benson 16.1 25 * Dimensions: 1" x 1.25" (with mounting tabs), 1" x 1" (without mounting tabs)
Coleman Benson 1.1 26
27 (((
Eric Nantel 38.1 28 = Pinout =
Eric Nantel 11.1 29
Eric Nantel 91.1 30 |(% rowspan="7" style="width:350px" %){{lightbox image="LSS-POWERHUB-TOP-PinOut.png"/}}|(% rowspan="7" style="width:350px" %){{lightbox image="LSS-POWERHUB-BOTTOM-PinOut.png"/}}|(% style="vertical-align:middle; width:35px" %)[[image:[email protected]]]|(% style="vertical-align:middle" %)(((
Brahim Daouas 77.7 31 **Vin / Separate Vin**: With the Vin jumper in place, all servos connected to the hub are powered via the same source (blue and red power lines become connected). With the Vin jumper removed, the connector marked with an asterisk * is decoupled from the other three servos (blue and red no longer share Vin), allowing them to be powered separately from the barrel connector or other source.
Coleman Benson 74.1 32 )))
Eric Nantel 92.1 33 |(% style="vertical-align:middle" %)[[image:[email protected]]]|(% style="vertical-align:middle" %)**Vin**: With the jumper in place, all servos connected to the power hub are powered via the same source. Refer to the Voltage section of the [[LSS - Specifications>>doc:lynxmotion-smart-servo.lss-specifications.WebHome]] page to understand which voltages are meant to be connected to this pin.
Eric Nantel 91.1 34 |(% style="vertical-align:middle" %)[[image:[email protected]]]|(% style="vertical-align:middle" %)**Ground (G)**: This pin should be connected to both the communication source's ground, as well as that of the power source (principle of "common ground"). When the Vin jumper is removed, ground is kept common.
35 |(% style="vertical-align:middle" %)[[image:[email protected]]]|(% style="vertical-align:middle" %)**Servo Rx pin (Rx)**: In serial mode, this pin should be connected to the Tx pin of a TTL serial device.
36 |(% style="vertical-align:middle" %)[[image:[email protected]]]|(% style="vertical-align:middle" %)**Servo Tx pin (Tx)**: In serial mode, this pin should be connected to the Rx pin of a TTL serial device.
Eric Nantel 36.1 37
Eric Nantel 34.1 38 = Wiring =
39
Eric Nantel 41.1 40 |(% style="width:350px" %){{lightbox image="LSS-POWERHUB-WIRING-Single.png"/}}|(((
Eric Nantel 33.1 41 == Single Power Hub ==
42
Brahim Daouas 77.12 43 A single Power Hub mounted on the servo (12 possible mounting positions on a servo) shows how a servo can be powered with a power supply (a wall adapter for example) through a 2.1mm x 5.5mm center positive plug.
Brahim Daouas 77.10 44
45 //Note: Cable colors are intended to show functionality (actual cables are all black).//
Coleman Benson 1.1 46 )))
Eric Nantel 41.1 47 |(% style="width:350px" %){{lightbox image="LSS-POWERHUB-WIRING-Multiple.png"/}}|(((
Eric Nantel 37.1 48 == Multiple Power Hubs ==
Eric Nantel 33.1 49
Brahim Daouas 77.17 50 Two Power Hubs in use: first which is mounted to the servo on the right is used to power that servo. Second hub which is mounted to the servo on the left allows two additional servos to be on the same bus but use a separate power source. Note that the Vin jumpers are removed on both hubs.
Brahim Daouas 77.14 51
52 //Note: Cable colors are intended to show functionality (actual cables are all black).//
Coleman Benson 1.1 53 )))
54
Eric Nantel 103.1 55 = Dimensions & Mounting =
Coleman Benson 16.1 56
Eric Nantel 103.1 57 |(% style="width:300px" %){{lightbox image="LSS-POWERHUB-Dimensions.png"/}}|(% style="width:300px" %)[[image:servo-erector-set-system.ses-electronics.ses-modules.lss-2io-board.WebHome@LSS-2IO-Mounting.gif]]|
Copyright RobotShop 2018