Changes for page LSS-PRO Configure IDs
Last modified by Coleman Benson on 2024/10/08 12:52
Change comment: There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -xwiki:XWiki. ENantel1 +xwiki:XWiki.CBenson - Content
-
... ... @@ -1,21 +1,23 @@ 1 1 (% style="width:710px" %) 2 2 |(% colspan="2" %)((( 3 -= LSS-PRO Configure IDs = 3 +== LSS-PRO Configure IDs == 4 4 ))) 5 5 |(% style="width:25px" %) |((( 6 6 ~1. Wiring 7 7 8 -__W arning:Make sureyourpower supply is OFF and wait at least 10s before connecting to the LSS-P actuator.__8 +__WARNING:**Do not hot plug the servo!** Make sure the power supply is turned OFF (and waited at least 10s for it to completely discharge its internal capacitor) before connecting it to the LSS-P actuator__ 9 9 10 10 * ((( 11 11 Connect the XT60 from your power supply 12 12 ))) 13 13 * Connect the USB Type-C cable 14 + 15 +If you are using a battery, ensure there is an On/Off switch between the battery and the servo(s). 14 14 ))) 15 15 | |((( 16 -2. Power -Up18 +2. Power ON 17 17 18 -* P roceedwith poweringthe actuator20 +* Power the actuator (set the switch to ON) 19 19 ))) 20 20 | |((( 21 21 3. LSS PRO Config Software ... ... @@ -26,9 +26,9 @@ 26 26 [[image:ses-pro.lss-pro.lss-p-configuration-software.lss-p-config-configure-ids.WebHome@LSS-P-ID-Config-Open.png]] 27 27 ))) 28 28 | |((( 29 -4. Connect ion31 +4. Connect to the BUS 30 30 31 -* Select the COM port associated with your actuator 33 +* Select the COM port associated with your actuator or the first servo in the BUS 32 32 * Click Connect 33 33 34 34 [[image:ses-pro.lss-pro.lss-p-configuration-software.lss-p-config-configure-ids.WebHome@LSS-P-ID-Config-COM.png]] ... ... @@ -41,21 +41,21 @@ 41 41 [[image:ses-pro.lss-pro.lss-p-configuration-software.lss-p-config-configure-ids.WebHome@LSS-P-ID-Config-Select.png]] 42 42 ))) 43 43 | |((( 44 -6. Set the ID 46 +6. Set the servo's ID 45 45 46 -* In the "Configuration" drop-down menu, select "CID / ID Number" 48 +* In the "Configuration" drop-down menu, select the **C**onfigure **ID** command "CID / ID Number" 47 47 48 48 [[image:ses-pro.lss-pro.lss-p-configuration-software.lss-p-config-configure-ids.WebHome@LSS-P-ID-Config-CID.png]] 49 49 50 -* In the text entry box, set the desired ID number 52 +* In the text entry box, set the desired ID number (integers only up to 253) 51 51 52 52 [[image:ses-pro.lss-pro.lss-p-configuration-software.lss-p-config-configure-ids.WebHome@LSS-P-ID-Config-ID1.png]] 53 53 54 -* Click on the "Send" button 56 +* Click on the "Send" button to send the command to the servo 55 55 56 56 [[image:ses-pro.lss-pro.lss-p-configuration-software.lss-p-config-configure-ids.WebHome@LSS-P-ID-Config-Send.png]] 57 57 58 -* The "RESET" button will start blinking, click on it to reset 60 +* The "RESET" button will start blinking, click on it to reset the servo 59 59 60 60 [[image:ses-pro.lss-pro.lss-p-configuration-software.lss-p-config-configure-ids.WebHome@LSS-P-ID-Config-Reset.png]] 61 61 ))) ... ... @@ -62,10 +62,11 @@ 62 62 | |((( 63 63 7. Confirm 64 64 65 -* The software will automatically re-connect to the actuator but if not youcandoit manually like in66 -* Verify that your ID is not what you have set it at67 +* The software will automatically re-connect to the actuator but if not, proceed as done in Step 4 68 +* Verify that your ID is not what you have set 67 67 68 68 [[image:ses-pro.lss-pro.lss-p-configuration-software.lss-p-config-configure-ids.WebHome@LSS-P-ID-Config-ID1-Confirm.png]] 69 69 70 70 At that point your Actuator should have the new ID configured. 71 71 ))) 74 +| |8. Repeat individualls for each servo in the BUS ensuring only one servo at a time is connected via its own USB to the software.