Changes for page LSS-PRO Configure IDs

Last modified by Coleman Benson on 2024/10/08 12:52

From version < 4.1 >
edited by Eric Nantel
on 2024/07/25 11:16
To version < 20.1 >
edited by Eric Nantel
on 2024/07/25 12:01
< >
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -11,10 +11,20 @@
11 11  
12 12  * Proceed with powering the actuator
13 13  
14 -= Step 3 - Software =
14 += =
15 15  
16 -* Install the LSS PRO Configuration software (HERE)
16 +*
17 +
18 +|(% style="width:35px" %) |
19 +|(% style="width:35px" %) |
20 +|(% colspan="2" style="width:35px" %)(((
21 += Step 3 - Software =
22 +)))
23 +|(% style="width:35px" %) |(((
24 +* Install the LSS PRO Configuration software ([[HERE>>doc:ses-pro.lss-pro.lss-p-configuration-software.WebHome]])
17 17  * Open the LSS PRO Configuration software
26 +)))
27 +|(% style="width:35px" %) |[[image:LSS-P-ID-Config-Open.png]]
18 18  
19 19  = Step 4 - Connection =
20 20  
... ... @@ -21,15 +21,37 @@
21 21  * Select the COM port associated with your actuator
22 22  * Click Connect
23 23  
34 +|(% style="width:35px" %) |[[image:LSS-P-ID-Config-COM.png]]
35 +
24 24  = Step 5 - Selection =
25 25  
26 26  * In the drop-down menu, select your actuator
27 27  
40 +|(% style="width:35px" %) |[[image:LSS-P-ID-Config-Select.png]]
41 +
28 28  = Step 6 - Set the ID =
29 29  
30 30  * In the "Configuration" drop-down menu, select "CID / ID Number"
45 +
46 +|(% style="width:35px" %) |[[image:LSS-P-ID-Config-CID.png]]
47 +
31 31  * In the text entry box, set the desired ID number
49 +
50 +|(% style="width:35px" %) |[[image:LSS-P-ID-Config-ID1.png]]
51 +
32 32  * Click on the "Send" button
33 -* Click on the "Reset button
34 34  
54 +|(% style="width:35px" %) |[[image:LSS-P-ID-Config-Send.png]]
55 +
56 +* The "RESET" button will start blinking, click on it to reset
57 +
58 +|(% style="width:35px" %) |[[image:LSS-P-ID-Config-Reset.png]]
59 +
60 += Step 7 - Confirm =
61 +
62 +* The software will automatically re-connect to the actuator but if not you can do it manually like in Step 4
63 +* Verify that your ID is not what you have set it at
64 +
65 +|(% style="width:35px" %) |[[image:LSS-P-ID-Config-ID1-Confirm.png]]
66 +
35 35  At that point your Actuator should have the new ID configured.
LSS-P-ID-Config-CID.png
Author
... ... @@ -1,0 +1,1 @@
1 +xwiki:XWiki.ENantel
Size
... ... @@ -1,0 +1,1 @@
1 +33.9 KB
Content
LSS-P-ID-Config-COM.png
Author
... ... @@ -1,0 +1,1 @@
1 +xwiki:XWiki.ENantel
Size
... ... @@ -1,0 +1,1 @@
1 +12.4 KB
Content
LSS-P-ID-Config-ID1-Confirm.png
Author
... ... @@ -1,0 +1,1 @@
1 +xwiki:XWiki.ENantel
Size
... ... @@ -1,0 +1,1 @@
1 +6.6 KB
Content
LSS-P-ID-Config-ID1.png
Author
... ... @@ -1,0 +1,1 @@
1 +xwiki:XWiki.ENantel
Size
... ... @@ -1,0 +1,1 @@
1 +17.4 KB
Content
LSS-P-ID-Config-Open.png
Author
... ... @@ -1,0 +1,1 @@
1 +xwiki:XWiki.ENantel
Size
... ... @@ -1,0 +1,1 @@
1 +178.7 KB
Content
LSS-P-ID-Config-Reset.png
Author
... ... @@ -1,0 +1,1 @@
1 +xwiki:XWiki.ENantel
Size
... ... @@ -1,0 +1,1 @@
1 +7.8 KB
Content
LSS-P-ID-Config-Select.png
Author
... ... @@ -1,0 +1,1 @@
1 +xwiki:XWiki.ENantel
Size
... ... @@ -1,0 +1,1 @@
1 +6.5 KB
Content
LSS-P-ID-Config-Send.png
Author
... ... @@ -1,0 +1,1 @@
1 +xwiki:XWiki.ENantel
Size
... ... @@ -1,0 +1,1 @@
1 +17.5 KB
Content
Copyright RobotShop 2018