Wiki source code of LSS-PRO Configure IDs
Version 5.1 by Eric Nantel on 2024/07/25 11:25
Show last authors
1 | = Step 1 - Connections = |
2 | |
3 | __Warning: Make sure your power supply is OFF and wait at least 10s before connecting to the LSS-P actuator.__ |
4 | |
5 | * ((( |
6 | Connect the XT60 from your power supply |
7 | ))) |
8 | * Connect the USB Type-C cable |
9 | |
10 | = Step 2 - Power-Up = |
11 | |
12 | * Proceed with powering the actuator |
13 | |
14 | = Step 3 - Software = |
15 | |
16 | * Install the LSS PRO Configuration software ([[HERE>>doc:ses-pro.lss-pro.lss-p-configuration-software.WebHome]]) |
17 | * Open the LSS PRO Configuration software |
18 | |
19 | |
20 | = Step 4 - Connection = |
21 | |
22 | * Select the COM port associated with your actuator |
23 | * Click Connect |
24 | |
25 | |
26 | = Step 5 - Selection = |
27 | |
28 | * In the drop-down menu, select your actuator |
29 | |
30 | |
31 | = Step 6 - Set the ID = |
32 | |
33 | * In the "Configuration" drop-down menu, select "CID / ID Number" |
34 | * In the text entry box, set the desired ID number |
35 | * Click on the "Send" button |
36 | * The "RESET" button will start blinking, click on it to reset |
37 | |
38 | |
39 | = Step 7 - Confirm = |
40 | |
41 | * The software will automatically re-connect to the actuator but if not you can do it manually like in Step 4 |
42 | * Verify that your ID is not what you have set it at |
43 | |
44 | |
45 | At that point your Actuator should have the new ID configured. |