... ... @@ -1,0 +1,34 @@
1 +(% style="width:700px" %)
2 +|(% colspan="2" %)
3 +|(% style="width:350px" %)Connect the USB cable between your Arm and PC|(% colspan="1" rowspan="2" %){{lightbox image="https://wiki.lynxmotion.com/info/wiki/lynxmotion/download/servo-erector-set-robots-kits/ses-v2-robots/ses-v2-arms/lss-4dof-arm/4dof-arm-quickstart/4dof-electronics/WebHome/SESV2-LSS-ARTICULATED-ARM-ELECTRONICS-Step-03-B.PNG?="/}}
4 +|Connect the power adapter XT60 to your Arm
5 +|Power on the robot with the power supply ON/OFF switch|
6 +|Start the LSS FlowArm software|
7 +|Select the type of LSS Arm you are using (3 DoF / 4 DoF / 5 DoF)|
8 +|It will automatically try to find the connected Arm but, if not, you can manually choose theĀ appropriate COM port from the drop-down list & the baud rate (default is 115200)|
9 +|The software sends a query to servo ID1 and once a reply is received, it determines connection has been established and a green light will be displayed aside the COM port.|
10 +
11 += Connecting via USB =
12 +
13 +1. Connect the USB cable to the LSS Adapter board on your robot
14 +1. Plug the USB connector into the PC
15 +1. Connect your LSS to the LSS-Adapter with the Lynxmotion cable
16 +1. Connect the power to the LSS Adapter via the yellow XT60 plug
17 +1. Power on the robot (On/Off switch)
18 +1. Start the LSS FlowArm software
19 +1. Select the type of LSS Arm you are using (3 DoF / 4 DoF / 5 DoF)
20 +1. It will automatically try to find the connected Arm but, if not, you can manually choose theĀ appropriate COM port from the drop-down list & the baud rate (default is 115200)
21 +1. The software sends a query to servo ID1 and once a reply is received, it determines connection has been established and a green light will be displayed aside the COM port.
22 +
23 += Calibration =
24 +
25 +1. Go in "TEACH" mode with the button on the top bar.
26 +1. Manually place the arm in the correct position for your model and with the gripper closed. (see images bellow)
27 +1. Store the values or Offsets by clicking "STORE OFFSETS"
28 +1. At that point the arm should "stay" in that position once released
29 +1. Exit the "TEACH" mode by clicking it again
30 +
31 += Calibration Positions =
32 +
33 +|(% colspan="2" rowspan="1" style="text-align:center; vertical-align:middle" %)**4 DoF**|(% colspan="2" rowspan="1" style="text-align:center; vertical-align:middle" %)**3 DoF **
34 +|(% style="text-align:center; vertical-align:middle" %)[[image:[email protected]||width="200"]]|(% style="text-align:center; vertical-align:middle" %)[[image:[email protected]||width="200"]]|(% style="text-align:center; vertical-align:middle" %)[[image:[email protected]||width="200"]]|(% style="text-align:center; vertical-align:middle" %)[[image:[email protected]||alt="lss-flowarm-left-3dof.png" width="200"]]