... ... @@ -512,7 +512,7 @@
512 512  
513 513  Ex: #5Q<cr> might return *5Q6<cr>, which indicates the motor is holding a position.
514 514  
515 -|***Value returned (Q)**|**Status**|**Detailed description**
515 +|***Value returned**|**Status**|**Detailed description**
516 516  |ex: *5Q0<cr>|0: Unknown|LSS is unsure / unknown state
517 517  |ex: *5Q1<cr>|1: Limp|Motor driving circuit is not powered and horn can be moved freely
518 518  |ex: *5Q2<cr>|2: Free moving|Motor driving circuit is not powered and horn can be moved freely
... ... @@ -523,16 +523,8 @@
523 523  |ex: *5Q7<cr>|7: Outside limits|{More details coming soon}
524 524  |ex: *5Q8<cr>|8: Stuck|Motor cannot perform request movement at current speed setting
525 525  |ex: *5Q9<cr>|9: Blocked|Similar to stuck, but the motor is at maximum duty and still cannot move (i.e.: stalled)
526 -|ex: *5Q10<cr>|10: Safe Mode|A safety limit has been exceeded (temperature, peak current or extended high current draw).
526 +|ex: *5Q9<cr>|10: Safe Mode|A safety limit has been exceeded (temperature, peak current or extended high current draw).
527 527  
528 -(% class="wikigeneratedid" %)
529 -If a safety limit has been reached, the LED will flash red and the servo will stop providing torque (no longer react to commands which cause the motor to rotate). In order to determine which limit has been reached, send a Q1 command. The servo must be RESET in order to return to normal operation, though if a limit is still detected (for example the servo is still too hot), it will revert back to Safe Mode.
530 -
531 -|***Value returned (Q1)**|**Status**|**Detailed description**
532 -|ex: *5Q1<cr>|Current limit has been passed|Something cause the current to either spike, or remain too high for too long
533 -|ex: *5Q2<cr>|Input voltage detected is below or above acceptable range|Check the voltage of your batteries
534 -|ex: *5Q3<cr>|Temperature limit has been reached|The servo is too hot to continue operating safely.
535 -
536 536  ====== __24. Query Voltage (**QV**)__ ======
537 537  
538 538  Ex: #5QV<cr> might return *5QV11200<cr>
... ... @@ -660,7 +660,7 @@
660 660  
661 661  ====== __A6. Configure LED Blinking (**CLB**)__ ======
662 662  
663 -This command allows you to control when the RGB LED will blink the user set color (see [[16. RGB LED>>||anchor="H16.RGBLED28LED29"]] for details). This is very useful when visually seeing what the servo is doing. You can turn on or off blinking for various LSS status. The command requires that the servo be RESET. Here is the list and their associated value:
655 +This command allows you to control when the RGB LED will blink the user set color (see [[16. RGB LED>>||anchor="H16.RGBLED28LED29"]] for details). This is very useful when visually seeing what the servo is doing. You can turn on or off blinking for various LSS status. Here is the list and their associated value:
664 664  
665 665  (% style="width:195px" %)
666 666  |(% style="width:134px" %)**Blink While:**|(% style="width:58px" %)**#**
... ... @@ -681,5 +681,3 @@
681 681  Ex: #5CLB12<cr> only blink when accel or decel (accel 4 + decel 8 = 12)
682 682  Ex: #5CLB48<cr> only blink when free or travel (free 16 + travel 32 = 48)
683 683  Ex: #5CLB63<cr> blink in all status (1 + 2 + 4 + 8 + 16 + 32)
684 -
685 -RESETTING the servo is needed.