Last modified by Eric Nantel on 2025/06/06 07:47

From version < 186.1 >
edited by Brahim Daouas
on 2020/05/01 11:58
To version < 183.2 >
edited by Brahim Daouas
on 2020/05/01 11:35
< >
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -222,7 +222,7 @@
222 222  
223 223  {{html wiki="true" clean="false"}}
224 224  <div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
225 -Ex: #5RESET&lt;cr&gt;<div class="wikimodel-emptyline"></div>
225 +Ex: #5RESET<div class="wikimodel-emptyline"></div>
226 226  This command does a "soft reset" and reverts all commands to those stored in EEPROM (i.e. configuration commands).
227 227  Note: after a RESET command is received, the LSS will restart and perform initilization again, making it unavailable on the bus for a bit. See [[Session>>||anchor="HSession"]], note #2 for more details.<div class="wikimodel-emptyline"></div>
228 228  </div></div>
... ... @@ -260,18 +260,6 @@
260 260  </div></div>
261 261  {{/html}}
262 262  
263 -====== __Confirm__ ======
264 -
265 -{{html wiki="true" clean="false"}}
266 -<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
267 -Ex: #5CONFIRM&lt;cr&gt;<div class="wikimodel-emptyline"></div>
268 -
269 -This command is used to confirm changes after a Default or Update command.<div class="wikimodel-emptyline"></div>
270 -
271 -**Note:** After the CONFIRM command is sent, the servo will automatically perform a RESET.<div class="wikimodel-emptyline"></div>
272 -</div></div>
273 -{{/html}}
274 -
275 275  ====== __Configure RC Mode (**CRC**)__ ======
276 276  
277 277  {{html wiki="true" clean="false"}}
... ... @@ -753,26 +753,12 @@
753 753  
754 754  Configure First Position in Degrees (**CFD**)<div class="wikimodel-emptyline"></div>
755 755  
756 -Ex: #5CFD900&lt;cr&gt;<div class="wikimodel-emptyline"></div>
744 +Ex: #5CD900&lt;cr&gt;<div class="wikimodel-emptyline"></div>
757 757  
758 758  This configuration command means the servo, when set to smart mode, will immediately move to 90.0 degrees upon power up. Sending a CFD command without a number (Ex. #5CFD&lt;cr&gt;) results in the servo remaining limp upon power up. In order to remove the first position, send no value, ex: #5CFD&lt;cr&gt;
759 759  <div class="wikimodel-emptyline"></div></div></div>
760 760  {{/html}}
761 761  
762 -====== __Maximum Motor Duty (**MMD**)__ ======
763 -
764 -{{html wiki="true" clean="false"}}
765 -<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
766 -This command allows the user to limit the duty cycle value sent from the servo's MCU to the DC Motor driver. The duty cycle limit value can be within the range of 255 to 1023. The default value is 1023. A typical use-case for this command is active compliance.<div class="wikimodel-emptyline"></div>
767 -
768 -Query Maximum Motor Duty (**QMMD**)<div class="wikimodel-emptyline"></div>
769 -
770 -Ex: #5QMMDD&lt;cr&gt; might return *5QMMD512&lt;cr&gt; <div class="wikimodel-emptyline"></div>
771 -
772 -The reply above indicates that servo with ID 5 motor duty is limited to 512.<div class="wikimodel-emptyline"></div>
773 -<div class="wikimodel-emptyline"></div></div></div>
774 -{{/html}}
775 -
776 776  ====== __Maximum Speed in Degrees (**SD**)__ ======
777 777  
778 778  {{html wiki="true" clean="false"}}
Copyright RobotShop 2018