1 -xwiki:XWiki.CBenson
1 +xwiki:XWiki.RB1
Content
... ... @@ -137,7 +137,7 @@
137 137  | 23|**M**odel| | QM| | | | none (integer)|
138 138  | 24|Serial **N**umber| | QN| | | | none (integer)|
139 139  | 25|**F**irmware version| | QF| | | | none (integer)|
140 -| 26|**Q**uery (general status)| | Q| | | ✓| none (integer from 1 to 8)|
140 +| 26|**Q**uery (general status)| | Q| | | ✓| none (integer from 1 to 8)| See command description for details
141 141  | 27|**V**oltage| | QV| | | ✓| tenths of volt (ex 113 = 11.3V; 92 = 9.2V)|
142 142  | 28|**T**emperature| | QT| | | ✓| degrees Celsius|
143 143  | 29|**C**urrent| | QC| | | ✓| tenths of Amps (ex 2 = 0.2A)|
... ... @@ -287,10 +287,10 @@
287 287  If #5QSD1<cr> is sent, the configured maximum speed (CSD value) will be returned instead. You can also query the current speed using "2" and the current target travel speed using "3". See the table below for an example:
288 288  
289 289  |**Command sent**|**Returned value (1/10 °)**
290 -|ex: #5QSD<cr>|Current session value for maximum speed (set by latest SD/SR command)
291 -|ex: #5QSD1<cr>|Current maximum speed configured (set by CSD/CSR)
292 -|ex: #5QSD2<cr>|Current speed.
293 -|ex: #5QSD3<cr>|Target travel speed.
290 +|ex: #5QSD<cr>|Session value for maximum speed (set by latest SD/SR command)
291 +|ex: #5QSD1<cr>|Configured maximum speed  (set by CSD/CSR)
292 +|ex: #5QSD2<cr>|Instantaneous speed (same as QWD)
293 +|ex: #5QSD3<cr>|Target travel speed
294 294  
295 295  Configure Speed in Degrees (**CSD**)
296 296  
... ... @@ -312,10 +312,10 @@
312 312  If #5QSR1<cr> is sent, the configured maximum speed (CSR value) will be returned instead. You can also query the current speed using "2" and the current target travel speed using "3". See the table below for an example:
313 313  
314 314  |**Command sent**|**Returned value (1/10 °)**
315 -|ex: #5QSR<cr>|Current session value for maximum speed (set by latest SD/SR command)
316 -|ex: #5QSR1<cr>|Current maximum speed configured (set by CSD/CSR)
317 -|ex: #5QSR2<cr>|Current speed.
318 -|ex: #5QSR3<cr>|Target travel speed.
315 +|ex: #5QSR<cr>|Session value for maximum speed (set by latest SD/SR command)
316 +|ex: #5QSR1<cr>|Configured maximum speed  (set by CSD/CSR)
317 +|ex: #5QSR2<cr>|Instantaneous speed (same as QWR)
318 +|ex: #5QSR3<cr>|Target travel speed
319 319  
320 320  Configure Speed in RPM (**CSR**)
321 321  
... ... @@ -323,11 +323,11 @@
323 323  
324 324  Using the CSR command sets the servo's maximum speed which is saved in EEPROM. In the example above, the servo's maximum speed will be set to 45rpm. When the servo is powered on (or after a reset), the CSR value is used. Note that CSD and CSR are effectively the same, but allow the user to specify the speed in either unit. The last command (either CSR or CSD) is what the servo uses for that session.
325 325  
326 -__14. Rigidity (R)__
326 +__14. Angular Stiffness (AS)__
327 327  
328 -The servo's rigidity can be thought of as (though not identical to) a damped spring in which the rigidity value affects the stiffness and embodies how much, and how quickly the servo tried keep the requested position against changes.
328 +The servo's rigidity / angular stiffness can be thought of as (though not identical to) a damped spring in which the value affects the stiffness and embodies how much, and how quickly the servo tried keep the requested position against changes.
329 329  
330 -A positive value of "rigidity":
330 +A positive value of "angular stiffness":
331 331  
332 332  * The more torque will be applied to try to keep the desired position against external input / changes
333 333  * The faster the motor will reach its intended travel speed and the motor will decelerate faster and nearer to its target position
... ... @@ -339,17 +339,17 @@
339 339  
340 340  The default value is zero and the effect becomes extreme by -4, +4. There are no units, only integers between -4 to 4. Greater values produce increasingly erratic behavior.
341 341  
342 -Ex: #5R-2<cr>
342 +Ex: #5AS-2<cr>
343 343  
344 -This reduces the rigidity to -2 for that session, allowing the servo to deviate more around the desired position. This can be beneficial in many situations such as impacts (legged robots) where more of a "spring" effect is desired. Upon reset, the servo will use the value stored in memory, based on the last configuration command.
344 +This reduces the angular stiffness to -2 for that session, allowing the servo to deviate more around the desired position. This can be beneficial in many situations such as impacts (legged robots) where more of a "spring" effect is desired. Upon reset, the servo will use the value stored in memory, based on the last configuration command.
345 345  
346 -Ex: #5QR<cr>
346 +Ex: #5QAS<cr>
347 347  
348 348  Queries the value being used.
349 349  
350 -Ex: #5CR<cr>
350 +Ex: #5CAS<cr>
351 351  
352 -Writes the desired rigidity value to memory.
352 +Writes the desired angular stiffness value to memory.
353 353  
354 354  __15. N/A (removed)__
355 355  
... ... @@ -482,9 +482,20 @@
482 482  
483 483  __26. Query Status (**Q**)__
484 484  
485 -Ex: #5Q<cr> might return *5Q_<cr>
485 +Ex: #5Q<cr> might return *5Q6<cr>, which indicates the motor is holding a position.
486 486  
487 -{Description coming soon}
487 +|*Value returned****|**Status**|**Detailed description**
488 +|ex: *5Q0<cr>|Unknown|LSS is unsure
489 +|ex: *5Q1<cr>|Limp|Motor driving circuit is not powered and horn can be moved freely
490 +|ex: *5Q2<cr>|Free moving|Motor driving circuit is not powered and horn can be moved freely
491 +|ex: *5Q3<cr>|Accelerating|Increasing speed from rest (or previous speeD) towards travel speed
492 +|ex: *5Q4<cr>|Traveling|Moving at a stable speed
493 +|ex: *5Q5<cr>|Deccelerating|Decreasing speed towards travel speed towards rest
494 +|ex: *5Q6<cr>|Holding|Keeping current position
495 +|ex: *5Q7<cr>|Stepping|Special low speed mode to maintain torque
496 +|ex: *5Q8<cr>|Outside limits|More details coming soon
497 +|ex: *5Q9<cr>|Stuck|Motor cannot perform request movement at current speed setting
498 +|ex: *5Q10<cr>|Blocked|Similar to stuck, but the motor is at maxiumum duty and still cannot move (i.e.: stalled)
488 488  
489 489  __27. Query Voltage (**QV**)__
490 490  
Copyright RobotShop 2018