Changes for page LSS Communication Protocol
Last modified by Eric Nantel on 2024/11/21 09:43
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -482,20 +482,9 @@ 482 482 483 483 __26. Query Status (**Q**)__ 484 484 485 -Ex: #5Q<cr> might return *5Q 6<cr>, which indicates the motor is holding a position.485 +Ex: #5Q<cr> might return *5Q_<cr> 486 486 487 -|*Value returned****|**Status**|**Detailed description** 488 -|ex: *5Q0<cr>|Unknown|LSS is unsure 489 -|ex: *5Q1<cr>|Limp|Motor driving circuit is not powered and horn can be moved freely 490 -|ex: *5Q2<cr>|Free moving|Motor driving circuit is not powered and horn can be moved freely 491 -|ex: *5Q3<cr>|Accelerating|Increasing speed from rest (or previous speeD) towards travel speed 492 -|ex: *5Q4<cr>|Traveling|Moving at a stable speed 493 -|ex: *5Q5<cr>|Deccelerating|Decreasing speed towards travel speed towards rest 494 -|ex: *5Q6<cr>|Holding|Keeping current position 495 -|ex: *5Q7<cr>|Stepping|Special low speed mode to maintain torque 496 -|ex: *5Q8<cr>|Outside limits|More details coming soon 497 -|ex: *5Q9<cr>|Stuck|Motor cannot perform request movement at current speed setting 498 -|ex: *5Q10<cr>|Blocked|Similar to stuck, but the motor is at maxiumum duty and still cannot move (i.e.: stalled) 487 +{Description coming soon} 499 499 500 500 __27. Query Voltage (**QV**)__ 501 501