... ... @@ -48,7 +48,7 @@
48 48  
49 49  == Configuration Commands ==
50 50  
51 -Configuration commands affect the servo's current session* but unlike action commands, configuration commands are written to EEPROM and are retained even if the servo loses power (therefore NOT session specific). Not all action commands have a corresponding configuration and vice versa. Certain configurations are retained for when the servo is used in RC model. More information can be found on the [[LSS - RC PWM page>>doc:LSS - RC PWM.WebHome]].
51 +Configuration commands affect the servo's current session* but unlike action commands, configuration commands are written to EEPROM and are retained even if the servo loses power (therefore NOT session specific). Not all action commands have a corresponding configuration and vice versa. Certain configurations are retained for when the servo is used in RC model. More information can be found on the [[LSS - RC PWM page>>doc:LSS - Overview (DEV).LSS - RC PWM.WebHome]].
52 52  
53 53  1. Start with a number sign # (U+0023)
54 54  1. Servo ID number as an integer
... ... @@ -139,7 +139,7 @@
139 139  | 25|**F**irmware version| | QF| | | | none (integer)|
140 140  | 26|**Q**uery (general status)| | Q| | | ✓| none (integer from 1 to 8)| See command description for details
141 141  | 27|**V**oltage| | QV| | | ✓| tenths of volt (ex 113 = 11.3V; 92 = 9.2V)|
142 -| 28|**T**emperature| | QT| | | ✓| degrees Celsius|
142 +| 28|**T**emperature| | QT| | | ✓| degrees Celsius|Max temp before error: 85°C (servo goes limp)
143 143  | 29|**C**urrent| | QC| | | ✓| tenths of Amps (ex 2 = 0.2A)|
144 144  | | | | | | | | |
145 145  | | | | | | | | |
Copyright RobotShop 2018