Last modified by Eric Nantel on 2024/11/21 09:43

From version < 39.1 >
edited by Coleman Benson
on 2018/05/24 14:26
To version < 42.1 >
edited by Coleman Benson
on 2018/06/29 11:59
< >
Change comment: There is no comment for this version

Summary

Details

Page properties
Parent
... ... @@ -1,1 +1,1 @@
1 -Main.WebHome
1 +lynxmotion:LSS - Overview (DEV).WebHome
Content
... ... @@ -48,7 +48,7 @@
48 48  
49 49  == Configuration Commands ==
50 50  
51 -Configuration commands affect the servo's current session* but unlike action commands, configuration commands are written to EEPROM and are retained even if the servo loses power (therefore NOT session specific). Not all action commands have a corresponding configuration and vice versa. Certain configurations are retained for when the servo is used in RC model. More information can be found on the [[LSS - RC PWM page>>doc:LSS - RC PWM.WebHome]].
51 +Configuration commands affect the servo's current session* but unlike action commands, configuration commands are written to EEPROM and are retained even if the servo loses power (therefore NOT session specific). Not all action commands have a corresponding configuration and vice versa. Certain configurations are retained for when the servo is used in RC model. More information can be found on the [[LSS - RC PWM page>>doc:LSS - Overview (DEV).LSS - RC PWM.WebHome]].
52 52  
53 53  1. Start with a number sign # (U+0023)
54 54  1. Servo ID number as an integer
... ... @@ -139,10 +139,10 @@
139 139  | 25|**F**irmware version| | QF| | | | none (integer)|
140 140  | 26|**Q**uery (general status)| | Q| | | ✓| none (integer from 1 to 8)| See command description for details
141 141  | 27|**V**oltage| | QV| | | ✓| tenths of volt (ex 113 = 11.3V; 92 = 9.2V)|
142 -| 28|**T**emperature| | QT| | | ✓| degrees Celsius|
142 +| 28|**T**emperature| | QT| | | ✓| degrees Celsius|Max temp before error: 85°C (servo goes limp)
143 143  | 29|**C**urrent| | QC| | | ✓| tenths of Amps (ex 2 = 0.2A)|
144 +|30|**RC** Mode| | |CRC| |✓| |Puts the servo into RC mode. To revert to serial mode, use the button menu.
144 144  | | | | | | | | |
145 -| | | | | | | | |
146 146  
147 147  = Details =
148 148  
... ... @@ -511,12 +511,18 @@
511 511  
512 512  The units are in tenths of degrees Celcius, so in the example above, the servo's internal temperature is 56.4 degrees C. To convert from degrees Celcius to degrees Farenheit, multiply by 1.8 and add 32. Therefore 56.4C = 133.52F.
513 513  
514 -__29. Query Current (QC)__
514 +__29. Query Current (**QC**)__
515 515  
516 516  Ex: #5QC<cr> might return *5QC140<cr>
517 517  
518 518  The units are in milliamps, so in the example above, the servo is consuming 140mA, or 0.14A.
519 519  
520 +__20. RC Mode (**CRC**)__
521 +
522 +This command puts the servo into RC mode, where it will only respond to RC pulses. Note that because this is the case, the servo will no longer accept serial commands. The servo can be placed back into serial model only using the button menu.
523 +
524 +EX: #5CRC<cr>
525 +
520 520  __**RESET**__
521 521  
522 522  Ex: #5RESET<cr> or #5RS<cr>
Copyright RobotShop 2018