Changes for page LSS Communication Protocol
Last modified by Eric Nantel on 2024/11/21 09:43
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -522,16 +522,10 @@ 522 522 523 523 The units are in milliamps, so in the example above, the servo is consuming 140mA, or 0.14A. 524 524 525 -__ 30. RC Mode (**CRC**)__525 +__20. RC Mode (**CRC**)__ 526 526 527 -This command puts the servo into RC mode (position or continuous), where it will only respond to RC pulses. Note that because this is the case, the servo will no longer accept serial commands. The servo can be placed back into smart modeby using the button menu.527 +This command puts the servo into RC mode, where it will only respond to RC pulses. Note that because this is the case, the servo will no longer accept serial commands. The servo can be placed back into smart mode only using the button menu. 528 528 529 -|**Command sent**|**Note** 530 -|ex: #5CRC<cr>|Stay in smart mode. 531 -|ex: #5CRC1<cr>|Change to RC position mode. 532 -|ex: #5CRC2<cr>|Change to RC continuous (wheel) mode. 533 -|ex: #5CRC***<cr>**|Where *** is any number or value. Stay in smart mode.** 534 - 535 535 EX: #5CRC<cr> 536 536 537 537 __**RESET**__