... ... @@ -162,7 +162,7 @@ 162 162 | 24|Serial **N**umber| | QN| | | | none (integer)| 163 163 | 25|**F**irmware version| | QF| | | | none (integer)| 164 164 | 26|**Q**uery (general status)| | Q| | | ✓| none (integer from 1 to 8)| See command description for details 165 -| 27|**V**oltage| | QV| | | ✓| millivolts(ex5936=5936mV =5.936V)|165 +| 27|**V**oltage| | QV| | | ✓| tenths of volt (ex 113 = 11.3V; 92 = 9.2V)| 166 166 | 28|**T**emperature| | QT| | | ✓| degrees Celsius|Max temp before error: 85°C (servo goes limp) 167 167 | 29|**C**urrent| | QC| | | ✓| tenths of Amps (ex 2 = 0.2A)| 168 168 | 30|**RC** Mode| | |CRC| |✓|none|((( ... ... @@ -590,4 +590,4 @@ 590 590 591 591 Note that after the CONFIRM command is sent, the servo will automatically perform a RESET. 592 592 593 -=== 593 +=== ===