Last modified by Eric Nantel on 2024/11/21 09:43

From version < 64.15 >
edited by RB1
on 2018/11/19 09:30
To version < 64.17 >
edited by RB1
on 2018/11/19 09:32
< >
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -187,31 +187,31 @@
187 187  
188 188  This action causes the servo to go "limp". The microcontroller will still be powered, but the motor will not. As an emergency safety feature, should the robot not be doing what it is supposed to or risks damage, use the broadcast ID to set all servos limp #254L<cr>.
189 189  
190 -__2. Halt & Hold (**H**)__
190 +====== __2. Halt & Hold (**H**)__ ======
191 191  
192 192  Example: #5H<cr>
193 193  
194 194  This action overrides whatever the servo might be doing at the time the command is received (accelerating, moving continuously etc.) and causes it to stop immediately and hold that position.
195 195  
196 -__3. Timed move (**T**)__
196 +====== __3. Timed move (**T**)__ ======
197 197  
198 198  Example: #5P1500T2500<cr>
199 199  
200 200  Timed move can be used only as a modifier for a position (P) action. The units are in milliseconds, so a timed move of 2500 milliseconds would cause the servo to rotate from its current position to the desired position in 2.5 seconds. This command is in place to ensure backwards compatibility with the SSC-32 / 32U protocol.
201 201  
202 -__4. Speed (**S**)__
202 +====== __4. Speed (**S**)__ ======
203 203  
204 204  Example: #5P1500S750<cr>
205 205  
206 206  This command is a modifier only for a position (P) action and determines the speed of the move in microseconds per second. A speed of 750 microseconds would cause the servo to rotate from its current position to the desired position at a speed of 750 microseconds per second. This command is in place to ensure backwards compatibility with the SSC-32 / 32U protocol.
207 207  
208 -__5. (Relative) Move in Degrees (**MD**)__
208 +====== __5. (Relative) Move in Degrees (**MD**)__ ======
209 209  
210 210  Example: #5MD123<cr>
211 211  
212 212  The relative move command causes the servo to read its current position and move the specified number of tenths of degrees in the corresponding position. For example if the servo is set to rotate CW (default) and an MD command of 123 is sent to the servo, it will cause the servo to rotate clockwise by 12.3 degrees. Negative commands would cause the servo to rotate in the opposite configured direction.
213 213  
214 -__6. Origin Offset Action (**O**)__
214 +====== __6. Origin Offset Action (**O**)__ ======
215 215  
216 216  Example: #5O2400<cr>
217 217  
... ... @@ -235,7 +235,7 @@
235 235  
236 236  This command allows you to change the origin of the servo in relation to the factory zero position in EEPROM. The setting will be saved upon servo reset / power cycle. Origin offset configuration commands are not cumulative and always relate to factory zero. The new origin is also used in RC mode.
237 237  
238 -__7. Angular Range (**AR**)__
238 +====== __7. Angular Range (**AR**)__ ======
239 239  
240 240  Example: #5AR1800<cr>
241 241  
... ... @@ -259,7 +259,7 @@
259 259  
260 260  This command allows you to change the total angular range of the servo in tenths of degrees in EEPROM. The setting will be saved upon servo reset / power cycle.
261 261  
262 -__8. Position in Pulse (**P**)__
262 +====== __8. Position in Pulse (**P**)__ ======
263 263  
264 264  Example: #5P2334<cr>
265 265  
... ... @@ -272,7 +272,7 @@
272 272  This command queries the current angular position in PWM "units". The user must take into consideration that the response includes any angular range and origin configurations in order to determine the actual angle. 
273 273  Valid values for QP are {-500, [500, 2500], -2500}. Values outside the [500, 2500] range are given a negative corresponding end point value to indicate they are out of bounds (note that if the servo is physically located at one of the endpoints, it may return a negative number if it is a fraction of a degree beyond the position).
274 274  
275 -__9. Position in Degrees (**D**)__
275 +====== __9. Position in Degrees (**D**)__ ======
276 276  
277 277  Example: #5PD1456<cr>
278 278  
... ... @@ -286,7 +286,7 @@
286 286  
287 287  This means the servo is located at 13.2 degrees.
288 288  
289 -__10. Wheel Mode in Degrees (**WD**)__
289 +====== __10. Wheel Mode in Degrees (**WD**)__ ======
290 290  
291 291  Ex: #5WD900<cr>
292 292  
... ... @@ -298,7 +298,7 @@
298 298  
299 299  The servo replies with the angular speed in tenths of degrees per second. A negative sign would indicate the opposite direction (for factory default a negative value would be counter clockwise).
300 300  
301 -__11. Wheel Mode in RPM (**WR**)__
301 +====== __11. Wheel Mode in RPM (**WR**)__ ======
302 302  
303 303  Ex: #5WR40<cr>
304 304  
... ... @@ -310,7 +310,7 @@
310 310  
311 311  The servo replies with the angular speed in rpm. A negative sign would indicate the opposite direction (for factory default a negative value would be counter clockwise).
312 312  
313 -__12. Speed in Degrees (**SD**)__
313 +====== __12. Speed in Degrees (**SD**)__ ======
314 314  
315 315  Ex: #5SD1800<cr>
316 316  
... ... @@ -335,7 +335,7 @@
335 335  
336 336  Using the CSD command sets the servo's maximum speed which is saved in EEPROM. In the example above, the servo's maximum speed will be set to 180.0 degrees per second. When the servo is powered on (or after a reset), the CSD value is used. Note that CSD and CSR (described below) are effectively the same, but allow the user to specify the speed in either unit. The last command (either CSR or CSD) is what the servo uses for that session.
337 337  
338 -__13. Speed in RPM (**SR**)__
338 +====== __13. Speed in RPM (**SR**)__ ======
339 339  
340 340  Ex: #5SD45<cr>
341 341  
... ... @@ -360,7 +360,7 @@
360 360  
361 361  Using the CSR command sets the servo's maximum speed which is saved in EEPROM. In the example above, the servo's maximum speed will be set to 45rpm. When the servo is powered on (or after a reset), the CSR value is used. Note that CSD and CSR are effectively the same, but allow the user to specify the speed in either unit. The last command (either CSR or CSD) is what the servo uses for that session.
362 362  
363 -__14. Angular Stiffness (**AS**)__
363 +====== __14. Angular Stiffness (**AS**)__ ======
364 364  
365 365  The servo's rigidity / angular stiffness can be thought of as (though not identical to) a damped spring in which the value affects the stiffness and embodies how much, and how quickly the servo tried keep the requested position against changes.
366 366  
... ... @@ -388,7 +388,7 @@
388 388  
389 389  Writes the desired angular stiffness value to memory.
390 390  
391 -__15. Angular Hold Stiffness (**AH**)__
391 +====== __15. Angular Hold Stiffness (**AH**)__ ======
392 392  
393 393  The angular holding stiffness determines the servo's ability to hold a desired position under load. Values can be from -10 to 10, with the default being 0. Note that negative values mean the final position can be easily deflected.
394 394  
... ... @@ -408,19 +408,19 @@
408 408  
409 409  This writes the angular holding stiffness of servo #5 to 2 to EEPROM
410 410  
411 -__15b: Angular Acceleration (**AA**)__
411 +====== __15b: Angular Acceleration (**AA**)__ ======
412 412  
413 413  {More details to come}
414 414  
415 -__15c: Angular Deceleration (**AD**)__
415 +====== __15c: Angular Deceleration (**AD**)__ ======
416 416  
417 417  {More details to come}
418 418  
419 -__15d: Motion Control (**MC**)__
419 +====== __15d: Motion Control (**MC**)__ ======
420 420  
421 421  {More details to come}
422 422  
423 -__16. RGB LED (**LED**)__
423 +====== __16. RGB LED (**LED**)__ ======
424 424  
425 425  Ex: #5LED3<cr>
426 426  
... ... @@ -438,7 +438,7 @@
438 438  
439 439  Configuring the LED color via the CLED command sets the startup color of the servo after a reset or power cycle. Note that it also changes the session's LED color immediately as well.
440 440  
441 -__17. Identification Number__
441 +====== __17. Identification Number__ ======
442 442  
443 443  A servo's identification number cannot be set "on the fly" and must be configured via the CID command described below. The factory default ID number for all servos is 0. Since smart servos are intended to be daisy chained, in order to respond differently from one another, the user must set different identification numbers. Servos with the same ID and baud rate will all receive and react to the same commands.
444 444  
... ... @@ -454,7 +454,7 @@
454 454  
455 455  Setting a servo's ID in EEPROM is done via the CID command. All servos connected to the same serial bus will be assigned that ID. In most situations each servo must be set a unique ID, which means each servo must be connected individually to the serial bus and receive a unique CID number. It is best to do this before the servos are added to an assembly. Numbered stickers are provided to distinguish each servo after their ID is set, though you are free to use whatever alternative method you like.
456 456  
457 -__18. Baud Rate__
457 +====== __18. Baud Rate__ ======
458 458  
459 459  A servo's baud rate cannot be set "on the fly" and must be configured via the CB command described below. The factory default baud rate for all servos is 9600. Since smart servos are intended to be daisy chained, in order to respond to the same serial bus, all servos in that project should ideally be set to the same baud rate. Setting different baud rates will have the servos respond differently and may create issues. Available baud rates are: 9.6 kbps, 19.2 kbps, 38.4 kbps, 57.6 kbps, 115.2 kbps, 230.4 kbps, 250.0 kbps, 460.8 kbps, 500.0 kbps, 750.0 kbps*, 921.6 kbps*. Servos are shipped with a baud rate set to 9600. The baud rates are currently restricted to those above.
460 460  \*: Current tests reveal baud rates above 500 kbps are unstable and can cause timeouts. Please keep this in mind if using those / testing them out.
... ... @@ -471,7 +471,7 @@
471 471  
472 472  Sending this command will change the baud rate associated with servo ID 5 to 9600 bits per second.
473 473  
474 -__19. Gyre Rotation Direction__
474 +====== __19. Gyre Rotation Direction__ ======
475 475  
476 476  "Gyre" is defined as a circular course or motion. The effect of changing the gyre direction is as if you were to use a mirror image of a circle. CW = 1; CCW = -1. The factory default is clockwise (CW).
477 477  
... ... @@ -489,7 +489,7 @@
489 489  
490 490  This changes the gyre direction as described above and also writes to EEPROM.
491 491  
492 -__20. First / Initial Position (pulse)__
492 +====== __20. First / Initial Position (pulse)__ ======
493 493  
494 494  In certain cases, a user might want to have the servo move to a specific angle upon power up. We refer to this as "first position". The factory default has no first position value stored in EEPROM and therefore upon power up, the servo remains limp until a position (or hold command) is assigned. FP and FD are different in that FP is used for RC mode only, whereas FD is used for smart mode only.
495 495  
... ... @@ -505,7 +505,7 @@
505 505  
506 506  This configuration command means the servo, when set to RC mode, will immediately move to an angle equivalent to having received an RC pulse of 1550 microseconds upon power up. Sending a CFP command without a number results in the servo remaining limp upon power up (i.e. disabled).
507 507  
508 -__21. First / Initial Position (Degrees)__
508 +====== __21. First / Initial Position (Degrees)__ ======
509 509  
510 510  In certain cases, a user might want to have the servo move to a specific angle upon power up. We refer to this as "first position". The factory default has no first position value stored in EEPROM and therefore upon power up, the servo remains limp until a position (or hold command) is assigned. FP and FD are different in that FP is used for RC mode only, whereas FD is used for smart mode only.
511 511  
... ... @@ -521,37 +521,37 @@
521 521  
522 522  This configuration command means the servo, when set to smart mode, will immediately move to 6.4 degrees upon power up. Sending a CFD command without a number results in the servo remaining limp upon power up.
523 523  
524 -__22. Query Target Position in Degrees (**QDT**)__
524 +====== __22. Query Target Position in Degrees (**QDT**)__ ======
525 525  
526 526  Ex: #5QDT<cr> might return *5QDT6783<cr>
527 527  
528 528  The query target position command returns the target angle during and after an action which results in a rotation of the servo horn. In the example above, the servo is rotating to a virtual position of 678.3 degrees. Should the servo not have a target position or be in wheel mode, it will respond without a number (Ex: *5QDT<cr>).
529 529  
530 -__23. Query Model String (**QMS**)__
530 +====== __23. Query Model String (**QMS**)__ ======
531 531  
532 532  Ex: #5QMS<cr> might return *5QMSLSS-HS1cr>
533 533  
534 534  This reply means the servo model is LSS-HS1, meaning a high speed servo, first revision.
535 535  
536 -__23b. Query Model (**QM**)__
536 +====== __23b. Query Model (**QM**)__ ======
537 537  
538 538  Ex: #5QM<cr> might return *5QM68702699520cr>
539 539  
540 540  This reply means the servo model is 0xFFF000000 or 100, meaning a high speed servo, first revision.
541 541  
542 -__24. Query Serial Number (**QN**)__
542 +====== __24. Query Serial Number (**QN**)__ ======
543 543  
544 544  Ex: #5QN<cr> might return *5QN~_~_<cr>
545 545  
546 546  The number in the response is the servo's serial number which is set and cannot be changed.
547 547  
548 -__25. Query Firmware (**QF**)__
548 +====== __25. Query Firmware (**QF**)__ ======
549 549  
550 550  Ex: #5QF<cr> might return *5QF11<cr>
551 551  
552 552  The integer in the reply represents the firmware version with one decimal, in this example being 1.1
553 553  
554 -__26. Query Status (**Q**)__
554 +====== __26. Query Status (**Q**)__ ======
555 555  
556 556  Ex: #5Q<cr> might return *5Q6<cr>, which indicates the motor is holding a position.
557 557  
... ... @@ -568,25 +568,25 @@
568 568  |ex: *5Q9<cr>|Stuck|Motor cannot perform request movement at current speed setting
569 569  |ex: *5Q10<cr>|Blocked|Similar to stuck, but the motor is at maxiumum duty and still cannot move (i.e.: stalled)
570 570  
571 -__27. Query Voltage (**QV**)__
571 +====== __27. Query Voltage (**QV**)__ ======
572 572  
573 573  Ex: #5QV<cr> might return *5QV11200<cr>
574 574  
575 575  The number returned has one decimal, so in the case above, servo with ID 5 has an input voltage of 11.2V (perhaps a three cell LiPo battery).
576 576  
577 -__28. Query Temperature (**QT**)__
577 +====== __28. Query Temperature (**QT**)__ ======
578 578  
579 579  Ex: #5QT<cr> might return *5QT564<cr>
580 580  
581 581  The units are in tenths of degrees Celcius, so in the example above, the servo's internal temperature is 56.4 degrees C. To convert from degrees Celcius to degrees Farenheit, multiply by 1.8 and add 32. Therefore 56.4C = 133.52F.
582 582  
583 -__29. Query Current (**QC**)__
583 +====== __29. Query Current (**QC**)__ ======
584 584  
585 585  Ex: #5QC<cr> might return *5QC140<cr>
586 586  
587 587  The units are in milliamps, so in the example above, the servo is consuming 140mA, or 0.14A.
588 588  
589 -__30. RC Mode (**CRC**)__
589 +====== __30. RC Mode (**CRC**)__ ======
590 590  
591 591  This command puts the servo into RC mode (position or continuous), where it will only respond to RC pulses. Note that because this is the case, the servo will no longer accept serial commands. The servo can be placed back into smart mode by using the button menu.
592 592  
... ... @@ -598,13 +598,13 @@
598 598  
599 599  EX: #5CRC<cr>
600 600  
601 -__31. RESET__
601 +====== __31. RESET__ ======
602 602  
603 603  Ex: #5RESET<cr> or #5RS<cr>
604 604  
605 605  This command does a "soft reset" (no power cycle required) and reverts all commands to those stored in EEPROM (i.e. configuration commands).
606 606  
607 -__32. DEFAULT & CONFIRM__
607 +====== __32. DEFAULT & CONFIRM__ ======
608 608  
609 609  Ex: #5DEFAULT<cr>
610 610  
... ... @@ -616,7 +616,7 @@
616 616  
617 617  Note that after the CONFIRM command is sent, the servo will automatically perform a RESET.
618 618  
619 -__33. UPDATE & CONFIRM__
619 +====== __33. UPDATE & CONFIRM__ ======
620 620  
621 621  Ex: #5UPDATE<cr>
622 622  
Copyright RobotShop 2018