... ... @@ -155,7 +155,7 @@
155 155  | 15|[[**A**ngular **H**olding Stiffness>>||anchor="H15.AngularHoldStiffness28AH29"]]|AH|QAH|CAH| | ✓|none|-10 to +10, with default as 0.
156 156  |15b|[[**A**ngular **A**cceleration>>||anchor="H15b:AngularAcceleration28AA29"]]|AA|QAA|CAA| | ✓|degrees per second squared|Increments of 10 degrees per second squared
157 157  |15c|[[**A**ngular **D**eceleration>>||anchor="H15c:AngularDeceleration28AD29"]]|AD|QAD|CAD| | ✓|degrees per second squared|Increments of 10 degrees per second squared
158 -|15d|[[**E**nable **M**otion control>>||anchor="H15d:MotionControl28MC29"]]|EM|QEM| | | ✓|none|EM0 to disable motion control, EM1 to enable. Session specific / does not survive power cycles
158 +|15d|[[**M**otion **C**ontrol>>||anchor="H15d:MotionControl28MC29"]]|MC|QMC| | | ✓|none|MC0 to disable motion control, MC1 to enable. Session specific
159 159  | 16|[[**LED** Color>>||anchor="H16.RGBLED28LED29"]]| LED| QLED| CLED| ✓| ✓| none (integer from 1 to 8)|0=OFF 1=RED 2=GREEN 3= BLUE 4=YELLOW 5=CYAN 6=MAGENTA, 7=WHITE
160 160  | 17|[[**ID** #>>||anchor="H17.IdentificationNumber"]]| | QID| CID| | ✓| none (integer from 0 to 250)|Note: ID 254 is a "broadcast" which all servos respond to
161 161  | 18|[[**B**aud rate>>||anchor="H18.BaudRate"]]| B| QB| CB| | ✓| none (integer)|
... ... @@ -201,8 +201,6 @@
201 201  
202 202  Timed move can be used only as a modifier for a position (P) action. The units are in milliseconds, so a timed move of 2500 milliseconds would cause the servo to rotate from its current position to the desired position in 2.5 seconds. This command is in place to ensure backwards compatibility with the SSC-32 / 32U protocol.
203 203  
204 -Note: If the calculated speed at which a servo must rotate for a timed move is greater than its maximum speed (which depends on voltage and load), then it will move at its maximum speed, and the time of the move may be longer than requested.
205 -
206 206  ====== __4. Speed (**S**)__ ======
207 207  
208 208  Example: #5P1500S750<cr>
... ... @@ -420,7 +420,7 @@
420 420  
421 421  {More details to come}
422 422  
423 -====== __15d: Motion Control (**EM**)__ ======
421 +====== __15d: Motion Control (**MC**)__ ======
424 424  
425 425  {More details to come}
426 426  
Copyright RobotShop 2018