... ... @@ -99,7 +99,9 @@ 99 99 | 5|**M**ove in **D**egrees (relative)| MD| | | | ✓| tenths of degrees (ex 325 = 32.5 degrees; 91 = 9.1 degrees)| 100 100 | 6|**O**rigin Offset| O| QO| CO| ✓| ✓| tenths of degrees (ex 325 = 32.5 degrees; 91 = 9.1 degrees)| 101 101 | 7|**A**ngular **R**ange| AR| QAR| CAR| ✓| ✓| tenths of degrees (ex 325 = 32.5 degrees; 91 = 9.1 degrees)| 102 -| 8|Position in **P**ulse| P| QP| | | ✓| microseconds| 102 +| 8|Position in **P**ulse| P| QP| | | ✓| microseconds|((( 103 +See details below. 104 +))) 103 103 | 9|Position in **D**egrees| D| QD| | | ✓| tenths of degrees (ex 325 = 32.5 degrees; 91 = 9.1 degrees)| 104 104 | 10|**W**heel mode in **D**egrees| WD| QWD| | | ✓| tenths of degrees per second (ex 248 = 24.8 degrees per second)| 105 105 | 11|**W**heel mode in **R**PM| WR| QWR| | | ✓| rpm| ... ... @@ -108,11 +108,11 @@ 108 108 | 14|**A**ngular **A**cceleration| AA| QAA| CAA| ✓| ✓| tenths of degrees per second squared| 109 109 | 15|**A**ngular **D**eceleration| AD| QAD| CAD| ✓| ✓| tenths of degrees per second squared| 110 110 | 16|**LED** Color| LED| QLED| CLED| ✓| ✓| none (integer from 1 to 8)|0=OFF 1=RED 2=GREEN 3= BLUE 4=YELLOW 5=CYAN 6= 7=MAGENTA, 8=WHITE 111 -| 17|**ID** #| ID| QID| CID| | ✓| none (integer from 0 to 25 4)|113 +| 17|**ID** #| ID| QID| CID| | ✓| none (integer from 0 to 250)|Note: ID 254 is a "broadcast" which all servos respond to. 112 112 | 18|**B**aud rate| B| QB| CB| | ✓| none (integer)| 113 113 | 19|**G**yre direction (**G**)| G| QG| CG| ✓| ✓| none | Gyre / rotation direction where 1= CW (clockwise) -1 = CCW (counter-clockwise) 114 -| 20|**F**irst Position (**P**ulse)| | QFP|CFP | ✓| ✓| none | \\115 -| 21|**F**irst Position (**D**egrees)| | QFD|CFD| ✓| ✓| none | \\116 +| 20|**F**irst Position (**P**ulse)| | QFP|CFP | ✓| ✓| none | 117 +| 21|**F**irst Position (**D**egrees)| | QFD|CFD| ✓| ✓| none | 116 116 | 22|**T**arget (**D**egree) **P**osition| | QDT| | | ✓| tenths of degrees (ex 325 = 32.5 degrees; 91 = 9.1 degrees)| 117 117 | 23|**M**odel| | QM| | | | none (integer)| 118 118 | 24|Serial **N**umber| | QN| | | | none (integer)| ... ... @@ -121,8 +121,8 @@ 121 121 | 27|**V**oltage| | QV| | | ✓| tenths of volt (ex 113 = 11.3V; 92 = 9.2V)| 122 122 | 28|**T**emperature| | QT| | | ✓| degrees Celsius| 123 123 | 29|**C**urrent| | QC| | | ✓| tenths of Amps (ex 2 = 0.2A)| 124 -|| | | | | || | 125 -|| | | | | | | | 126 +| | | | | | | | | 127 +| | | | | | | | | 126 126 127 127 = Details = 128 128 ... ... @@ -208,13 +208,14 @@ 208 208 209 209 Example: #5P2334<cr> 210 210 211 -The position in PWM pulses was retained in order to be backward compatible with the SSC-32 / 32U protocol. This relates the desired angle with an RC standard PWM pulse and is further explained in the SSC-32 and SSC-32U manuals found on Lynxmotion.com. Without any modifications to configuration considered, and a ±90.0 degrees standard range where 1500 microseconds is centered, a pulse of 2334 would set the servo to 165.1 degrees 213 +The position in PWM pulses was retained in order to be backward compatible with the SSC-32 / 32U protocol. This relates the desired angle with an RC standard PWM pulse and is further explained in the SSC-32 and SSC-32U manuals found on Lynxmotion.com. Without any modifications to configuration considered, and a ±90.0 degrees standard range where 1500 microseconds is centered, a pulse of 2334 would set the servo to 165.1 degrees. Valid values for P are [500, 2500]. Values outside this range are corrected to end points. 212 212 213 213 Query Position in Pulse (**QP**) 214 214 215 215 Example: #5QP<cr> might return *5QP 216 216 217 -This command queries the current angular position in PWM "units". The user must take into consideration that the response includes any angular range and origin configurations in order to determine the actual angle. 219 +This command queries the current angular position in PWM "units". The user must take into consideration that the response includes any angular range and origin configurations in order to determine the actual angle. 220 +Valid values for QP are {-500, [500, 2500], -2500}. Values outside the [500, 2500] range are given a negative corresponding end point value to indicate they are out of bounds. 218 218 219 219 __9. Position in Degrees (**D**)__ 220 220 ... ... @@ -334,7 +334,7 @@ 334 334 335 335 This action sets the servo's RGB LED color for that session.The LED can be used for aesthetics, or (based on user code) to provide visual status updates. Using timing can create patterns. 336 336 337 -0=OFF 1=RED 2=GREEN 3= BLUE 4=YELLOW 5=CYAN 6= 7=MAGENTA, 8=WHITE 340 +0=OFF 1=RED 2=GREEN 3= BLUE 4=YELLOW 5=CYAN 6= 7=MAGENTA, 8=WHITE 338 338 339 339 Query LED Color (**QLED**) 340 340 ... ... @@ -482,23 +482,26 @@ 482 482 483 483 This command does a "soft reset" (no power cycle required) and reverts all commands to those stored in EEPROM (i.e. configuration commands). 484 484 485 -**__DEFAULT__** 488 +**__DEFAULT __**__& **CONFIRM**__ 486 486 487 487 Ex: #5DEFAULT<cr> 488 488 489 -This command sets all values to the default values included with the version of the firmware installed on that servo. 492 +This command sets in motion the reset all values to the default values included with the version of the firmware installed on that servo. The servo then waits for the CONFIRM command. Any other command received will cause the servo to exit the DEFAULT function. 490 490 491 - __**FIRMWARE**&**CONFIRM**__494 +EX: #5DEFAULT<cr> followed by #5CONFIRM<cr> 492 492 493 - Ex:#5FIRMWARE<cr>496 +Since it it not common to have to restore all configurations, a confirmation command is needed after a firmware command is sent. Should any command other than CONFIRM be received by the servo after the firmware command has been received, it will leave the firmware action. 494 494 495 -T his command clears all user-input values inEEPROMandreverts back to factory defaults for the firmware installed. It does not overwrite any firmware updates. To revert to an older firmware version, please refer to the LSS -Firmware page. The firmware command alone does nothing other than have the servo wait for a confirmation.498 +**__UPDATE __**__& **CONFIRM**__ 496 496 497 -E X: #5FIRMWARE<cr>followed by #5CONFIRM<cr>500 +Ex: #5UPDATE<cr> 498 498 499 - Sinceit itnotcommonto haveto restoreallconfigurations,a confirmationcommandis neededafterafirmwarecommand is sent.Shouldany command otherthanCONFIRMbe receivedby the servoafterthefirmware commandhasbeen received,itwillleave thefirmwareaction.502 +This command sets in motion the equivalent of a long button press when the servo is not powered in order to enter firmware update mode. This is useful should the button be broken or inaccessible. The servo then waits for the CONFIRM command. Any other command received will cause the servo to exit the UPDATE function. 500 500 504 +EX: #5UPDATE<cr> followed by #5CONFIRM<cr> 501 501 506 +Since it it not common to have to update firmware, a confirmation command is needed after an UPDATE command is sent. Should any command other than CONFIRM be received by the servo after the firmware command has been received, it will leave the firmware action. 507 + 502 502 === Virtual Angular Position === 503 503 504 504 {In progress}