Wiki source code of LSS - Communication Protocol

Version 22.1 by RB1 on 2018/05/04 08:33

Show last authors
1 The Lynxmotion Smart Servo (LSS) protocol was created in order to be as simple and straightforward as possible from a user perspective, while at the same time trying to stay compact and robust yet highly versatile. Almost everything one might expect to be able to configure for a smart servo motor is available.
2
3 === Session ===
4
5 A "session" is defined as the time between when the servo is powered ON to when it is powered OFF or reset.
6
7 == Action Commands ==
8
9 Action commands are sent serially to the servo's Rx pin and must be set in the following format:
10
11 1. Start with a number sign # (U+0023)
12 1. Servo ID number as an integer
13 1. Action command (one to three letters, no spaces, capital or lower case)
14 1. Action value in the correct units with no decimal
15 1. End with a control / carriage return '<cr>'
16
17 (((
18 Ex: #5PD1443<cr>
19
20 Move servo with ID #5 to a position of 144.3 degrees.
21
22 Action commands cannot be combined with query commands, and only one action command can be sent at a time.
23
24 Action commands are session-specific, therefore once a servo is power cycled, it will not have any "memory" of previous actions or virtual positions (as described at the bottom of this page).
25
26 === Action Modifiers ===
27
28 Two commands can be used as action modifiers only: Timed Move and Speed. The format is:
29
30 1. Start with a number sign # (U+0023)
31 1. Servo ID number as an integer
32 1. Action command (one to three letters, no spaces, capital or lower case)
33 1. Action value in the correct units with no decimal
34 1. Modifier command (one letter)
35 1. Modifier value in the correct units with no decimal
36 1. End with a control / carriage return '<cr>'
37
38 Ex: #5P1456T1263<cr>
39
40 Results in the servo rotating from the current angular position to a pulse position of 1456 in 1263 milliseconds.
41
42 Modified commands are command specific.
43 )))
44
45 (((
46
47 )))
48
49 == Configuration Commands ==
50
51 Configuration commands affect the servo's current session* but unlike action commands, configuration commands are written to EEPROM and are retained even if the servo loses power (therefore NOT session specific). Not all action commands have a corresponding configuration and vice versa. Certain configurations are retained for when the servo is used in RC model. More information can be found on the [[LSS - RC PWM page>>doc:Lynxmotion Smart Servos (LSS).LSS - RC PWM.WebHome]].
52
53 1. Start with a number sign # (U+0023)
54 1. Servo ID number as an integer
55 1. Configuration command (two to three letters, no spaces, capital or lower case)
56 1. Configuration value in the correct units with no decimal
57 1. End with a control / carriage return '<cr>'
58
59 Ex: #5CO-50<cr>
60
61 Assigns an absolute origin offset of -5.0 degrees (with respect to factory origin) to servo #5 and changes the offset for that session to -5.0 degrees.
62
63 Configuration commands are not cumulative, in that if two configurations are sent at any time, only the last configuration is used and stored.
64
65 *Important Note: the one exception is the baud rate - the servo's current session retains the given baud rate. The new baud rate will only be in place when the servo is power cycled.
66
67 == Query Commands ==
68
69 Query commands are sent serially to the servo's Rx pin and must be set in the following format:
70
71 1. Start with a number sign # (U+0023)
72 1. Servo ID number as an integer
73 1. Query command (one to three letters, no spaces, capital or lower case)
74 1. End with a control / carriage return '<cr>'
75
76 (((
77 Ex: #5QD<cr>Query position in degrees for servo #5
78 )))
79
80 (((
81 The query will return a value via the Tx pin with the following format:
82
83 1. Start with an asterisk (U+002A)
84 1. Servo ID number as an integer
85 1. Query command (one to three letters, no spaces, capital letters)
86 1. The reported value in the units described, no decimals.
87 1. End with a control / carriage return '<cr>'
88
89 (((
90 Ex: *5QD1443<cr>
91 )))
92
93 Indicates that servo #5 is currently at 144.3 degrees.
94
95 **Session vs Configuration Query**
96
97 By default, the query command returns the sessions' value; should no action commands have been sent to change, it will return the value saved in EEPROM from the last configuration command.
98
99 In order to query the value in EEPROM, add a '1' to the query command.
100
101 Ex: #5CSR20<cr> sets the maximum speed for servo #5 to 20rpm upon RESET (explained below).
102
103 After RESET: #5SR4<cr> sets the session's speed to 4rpm.
104
105 #5QSR<cr> would return *5QSR4<cr> which represents the value for that session.
106
107 #5QSR1<cr> would return *5QSR20<cr> which represents the value in EEPROM
108 )))
109
110 = Command List =
111
112 |= #|=Description|= Action|= Query|= Config|= RC|= Serial|= Units|= Notes
113 | 1|**L**imp| L| | | | ✓| none|
114 | 2|**H**alt & Hold| H| | | | ✓| none|
115 | 3|**T**imed move| T| | | | ✓| milliseconds| Modifier only
116 | 4|**S**peed| S| | | | ✓| microseconds / second| Modifier only
117 | 5|**M**ove in **D**egrees (relative)| MD| | | | ✓| tenths of degrees (ex 325 = 32.5 degrees; 91 = 9.1 degrees)|
118 | 6|**O**rigin Offset| O| QO| CO| ✓| ✓| tenths of degrees (ex 325 = 32.5 degrees; 91 = 9.1 degrees)|
119 | 7|**A**ngular **R**ange| AR| QAR| CAR| ✓| ✓| tenths of degrees (ex 325 = 32.5 degrees; 91 = 9.1 degrees)|
120 | 8|Position in **P**ulse| P| QP| | | ✓| microseconds|(((
121 See details below.
122 )))
123 | 9|Position in **D**egrees| D| QD| | | ✓| tenths of degrees (ex 325 = 32.5 degrees; 91 = 9.1 degrees)|
124 | 10|**W**heel mode in **D**egrees| WD| QWD| | | ✓| tenths of degrees per second (ex 248 = 24.8 degrees per second)|
125 | 11|**W**heel mode in **R**PM| WR| QWR| | | ✓| rpm|
126 | 12|**S**peed in **D**egrees| SD| QSD| CSD| ✓| ✓| tenths of degrees per second (ex 248 = 24.8 degrees per second)|
127 | 13|**S**peed in **R**PM| SR| QSR| CSR| ✓| ✓| rpm|
128 | 14|**R**igidity| R| QR| CR| ✓| ✓|none|
129 | 15|//N/A (removed)//| | | | | | |
130 | 16|**LED** Color| LED| QLED| CLED| ✓| ✓| none (integer from 1 to 8)|0=OFF 1=RED 2=GREEN 3= BLUE 4=YELLOW 5=CYAN 6= 7=MAGENTA, 8=WHITE
131 | 17|**ID** #| ID| QID| CID| | ✓| none (integer from 0 to 250)|Note: ID 254 is a "broadcast" which all servos respond to.
132 | 18|**B**aud rate| B| QB| CB| | ✓| none (integer)|
133 | 19|**G**yre direction (**G**)| G| QG| CG| ✓| ✓| none | Gyre / rotation direction where 1= CW (clockwise) -1 = CCW (counter-clockwise)
134 | 20|**F**irst Position (**P**ulse)| | QFP|CFP | ✓| ✓| none |
135 | 21|**F**irst Position (**D**egrees)| | QFD|CFD| ✓| ✓| none |
136 | 22|**T**arget (**D**egree) **P**osition| | QDT| | | ✓| tenths of degrees (ex 325 = 32.5 degrees; 91 = 9.1 degrees)|
137 | 23|**M**odel| | QM| | | | none (integer)|
138 | 24|Serial **N**umber| | QN| | | | none (integer)|
139 | 25|**F**irmware version| | QF| | | | none (integer)|
140 | 26|**Q**uery (general status)| | Q| | | ✓| none (integer from 1 to 8)|
141 | 27|**V**oltage| | QV| | | ✓| tenths of volt (ex 113 = 11.3V; 92 = 9.2V)|
142 | 28|**T**emperature| | QT| | | ✓| degrees Celsius|
143 | 29|**C**urrent| | QC| | | ✓| tenths of Amps (ex 2 = 0.2A)|
144 | | | | | | | | |
145 | | | | | | | | |
146
147 = Details =
148
149 __1. Limp (**L**)__
150
151 Example: #5L<cr>
152
153 This action causes the servo to go "limp". The microcontroller will still be powered, but the motor will not. As an emergency safety feature, should the robot not be doing what it is supposed to or risks damage, use the broadcast ID to set all servos limp #254L<cr>.
154
155 __2. Halt & Hold (**H**)__
156
157 Example: #5H<cr>
158
159 This action overrides whatever the servo might be doing at the time the command is received (accelerating, moving continuously etc.) and causes it to stop immediately and hold that position.
160
161 __3. Timed move (**T**)__
162
163 Example: #5P1500T2500<cr>
164
165 Timed move can be used only as a modifier for a position (P) action. The units are in milliseconds, so a timed move of 2500 milliseconds would cause the servo to rotate from its current position to the desired position in 2.5 seconds. This command is in place to ensure backwards compatibility with the SSC-32 / 32U protocol.
166
167 __4. Speed (**S**)__
168
169 Example: #5P1500S750<cr>
170
171 This command is a modifier only for a position (P) action and determines the speed of the move in microseconds per second. A speed of 750 microseconds would cause the servo to rotate from its current position to the desired position at a speed of 750 microseconds per second. This command is in place to ensure backwards compatibility with the SSC-32 / 32U protocol.
172
173 __5. (Relative) Move in Degrees (**MD**)__
174
175 Example: #5MD123<cr>
176
177 The relative move command causes the servo to read its current position and move the specified number of tenths of degrees in the corresponding position. For example if the servo is set to rotate CW (default) and an MD command of 123 is sent to the servo, it will cause the servo to rotate clockwise by 12.3 degrees. Negative commands would cause the servo to rotate in the opposite configured direction.
178
179 __6. Origin Offset Action (**O**)__
180
181 Example: #5O2400<cr>
182
183 This command allows you to temporarily change the origin of the servo in relation to the factory zero position. The setting will be lost upon servo reset / power cycle. Origin offset commands are not cumulative and always relate to factory zero. Note that for a given session, the O command overrides the CO command. In the first image, the origin at factory offset '0' (centered).
184
185 [[image:LSS-servo-default.jpg]]
186
187 In the second image, the origina, as well as the angular range (explained below) have been shifted by 240.0 degrees:
188
189 [[image:LSS-servo-origin.jpg]]
190
191 Origin Offset Query (**QO**)
192
193 Example: #5QO<cr> Returns: *5QO-13
194
195 This allows you to query the angle (in tenths of degrees) of the origin in relation to the factory zero position.
196
197 Configure Origin Offset (**CO**)
198
199 Example: #5CO-24<cr>
200
201 This command allows you to change the origin of the servo in relation to the factory zero position in EEPROM. The setting will be saved upon servo reset / power cycle. Origin offset configuration commands are not cumulative and always relate to factory zero. The new origin is also used in RC mode.
202
203 __7. Angular Range (**AR**)__
204
205 Example: #5AR1800<cr>
206
207 This command allows you to temporarily change the total angular range of the servo in tenths of degrees. This applies to the Position in Pulse (P) command and RC mode. The default for (P) and RC mode is 1800 (180.0 degrees total, or ±90.0 degrees). In the first image,
208
209 [[image:LSS-servo-default.jpg]]
210
211 Here, the angular range has been restricted to 180.0 degrees, or -90.0 to +90.0. The center has remained unchanged.
212
213 [[image:LSS-servo-ar.jpg]]
214
215 The angular range action command (ex. #5AR1800<cr>) and origin offset action command (ex. #5O-1200<cr>) an be used to move both the center and limit the angular range:
216
217 [[image:LSS-servo-ar-o-1.jpg]]
218
219 Query Angular Range (**QAR**)
220
221 Example: #5QAR<cr> might return *5AR2756
222
223 Configure Angular Range (**CAR**)
224
225 This command allows you to change the total angular range of the servo in tenths of degrees in EEPROM. The setting will be saved upon servo reset / power cycle.
226
227 __8. Position in Pulse (**P**)__
228
229 Example: #5P2334<cr>
230
231 The position in PWM pulses was retained in order to be backward compatible with the SSC-32 / 32U protocol. This relates the desired angle with an RC standard PWM pulse and is further explained in the SSC-32 and SSC-32U manuals found on Lynxmotion.com. Without any modifications to configuration considered, and a ±90.0 degrees standard range where 1500 microseconds is centered, a pulse of 2334 would set the servo to 165.1 degrees. Valid values for P are [500, 2500]. Values outside this range are corrected to end points.
232
233 Query Position in Pulse (**QP**)
234
235 Example: #5QP<cr> might return *5QP
236
237 This command queries the current angular position in PWM "units". The user must take into consideration that the response includes any angular range and origin configurations in order to determine the actual angle. 
238 Valid values for QP are {-500, [500, 2500], -2500}. Values outside the [500, 2500] range are given a negative corresponding end point value to indicate they are out of bounds.
239
240 __9. Position in Degrees (**D**)__
241
242 Example: #5PD1456<cr>
243
244 This moves the servo to an angle of 145.6 degrees, where the center (0) position is centered. Negative values (ex. -176 representing -17.6 degrees) are used. A full circle would be from -1800 to 1800 degrees. A value of 2700 would be the same angle as -900, except the servo would move in a different direction.
245
246 Larger values are permitted and allow for multi-turn functionality using the concept of virtual position.
247
248 Query Position in Degrees (**QD**)
249
250 Example: #5QD<cr> might return *5QD0<cr>
251
252 __10. Wheel Mode in Degrees (**WD**)__
253
254 Ex: #5WD900<cr>
255
256 This command sets the servo to wheel mode where it will rotate in the desired direction at the selected speed. The example above would have the servo rotate at 90.0 degrees per second clockwise (assuming factory default configurations).
257
258 Query Wheel Mode in Degrees (**QWD**)
259
260 Ex: #5QWD<cr> might return *5QWD900<cr>
261
262 The servo replies with the angular speed in tenths of degrees per second. A negative sign would indicate the opposite direction (for factory default a negative value would be counter clockwise).
263
264 __11. Wheel Mode in RPM (**WR**)__
265
266 Ex: #5WR40<cr>
267
268 This command sets the servo to wheel mode where it will rotate in the desired direction at the selected rpm. Wheel mode (a.k.a. "continuous rotation") has the servo operate like a geared DC motor. The servo's maximum rpm cannot be set higher than its physical limit at a given voltage. The example above would have the servo rotate at 40 rpm clockwise (assuming factory default configurations).
269
270 Query Wheel Mode in RPM (**QWR**)
271
272 Ex: #5QWR<cr> might return *5QWR40<cr>
273
274 The servo replies with the angular speed in rpm. A negative sign would indicate the opposite direction (for factory default a negative value would be counter clockwise).
275
276 __12. Speed in Degrees (**SD**)__
277
278 Ex: #5SD1800<cr>
279
280 This command sets the servo's maximum speed for action commands in tenths of degrees per second for that session. In the example above, the servo's maximum speed for that session would be set to 180.0 degrees per second. Therefore maximum speed for actions can be set "on the fly". The servo's maximum speed cannot be set higher than its physical limit at a given voltage. SD overrides CSD (described below) for that session. Upon reset or power cycle, the servo reverts to the value associated with CSD as described below. Note that SD and SR (described below) are effectively the same, but allow the user to specify the speed in either unit. The last command (either SR or SD) is what the servo uses for that session.
281
282 Query Speed in Degrees (**QSD**)
283
284 Ex: #5QSD<cr> might return *5QSD1800<cr>
285
286 Note that the QSD query will return the current servo speed. Querying the last maximum speed value set using SD or CSD is not possible.
287
288 Configure Speed in Degrees (**CSD**)
289
290 Ex: #5CSD1800<cr>
291
292 Using the CSD command sets the servo's maximum speed which is saved in EEPROM. In the example above, the servo's maximum speed will be set to 180.0 degrees per second. When the servo is powered on (or after a reset), the CSD value is used. Note that CSD and CSR (described below) are effectively the same, but allow the user to specify the speed in either unit. The last command (either CSR or CSD) is what the servo uses for that session.
293
294 __13. Speed in RPM (**SR**)__
295
296 Ex: #5SD45<cr>
297
298 This command sets the servo's maximum speed for action commands in rpm for that session. In the example above, the servo's maximum speed for that session would be set to 45rpm. Therefore maximum speed for actions can be set "on the fly". The servo's maximum speed cannot be set higher than its physical limit at a given voltage. SD overrides CSD (described below) for that session. Upon reset or power cycle, the servo reverts to the value associated with CSD as described below. Note that SD (described above) and SR are effectively the same, but allow the user to specify the speed in either unit. The last command (either SR or SD) is what the servo uses for that session.
299
300 Query Speed in Degrees (**QSR**)
301
302 Ex: #5QSR<cr> might return *5QSR45<cr>
303
304 Note that the QSD query will return the current servo speed. Querying the last maximum speed value set using SR or CSR is not possible.
305
306 Configure Speed in Degrees (**CSR**)
307
308 Ex: #5CSR45<cr>
309
310 Using the CSD command sets the servo's maximum speed which is saved in EEPROM. In the example above, the servo's maximum speed will be set to 45rpm. When the servo is powered on (or after a reset), the CSD value is used. Note that CSD and CSR are effectively the same, but allow the user to specify the speed in either unit. The last command (either CSR or CSD) is what the servo uses for that session.
311
312 __14. Rigidity (R)__
313
314 The servo's rigidity can be thought of as (though not identical to) a damped spring in which the rigidity value affects the stiffness and embodies how much, and how quickly the servo tried keep the requested position against changes.
315
316 A positive value of "rigidity":
317
318 * The more torque will be applied to try to keep the desired position against external input / changes
319 * The faster the motor will reach its intended travel speed and the motor will decelerate faster and nearer to its target position
320
321 A negative value on the other hand:
322
323 * Causes a slower acceleration to the travel speed, and a slower deceleration
324 * Allows the target position to deviate more from its position before additional torque is applied to bring it back
325
326 The default value is zero and the effect becomes extreme by -4, +4. There are no units, only integers between -4 to 4. Greater values produce increasingly erratic behavior.
327
328 Ex: #5R-2<cr>
329
330 This reduces the rigidity to -2 for that session, allowing the servo to deviate more around the desired position. This can be beneficial in many situations such as impacts (legged robots) where more of a "spring" effect is desired. Upon reset, the servo will use the value stored in memory, based on the last configuration command.
331
332 Ex: #5QR<cr>
333
334 Queries the value being used.
335
336 Ex: #5CR<cr>
337
338 Writes the desired rigidity value to memory.
339
340 __15. N/A (removed)__
341
342 This command has been removed.
343
344 __16. RGB LED (**LED**)__
345
346 Ex: #5LED3<cr>
347
348 This action sets the servo's RGB LED color for that session.The LED can be used for aesthetics, or (based on user code) to provide visual status updates. Using timing can create patterns.
349
350 0=OFF 1=RED 2=GREEN 3= BLUE 4=YELLOW 5=CYAN 6= 7=MAGENTA, 8=WHITE 
351
352 Query LED Color (**QLED**)
353
354 Ex: #5QLED<cr> might return *5QLED5<cr>
355
356 This simple query returns the indicated servo's LED color.
357
358 Configure LED Color (**CLED**)
359
360 Configuring the LED color via the CLED command sets the startup color of the servo after a reset or power cycle.
361
362 __17. Identification Number__
363
364 A servo's identification number cannot be set "on the fly" and must be configured via the CID command described below. The factory default ID number for all servos is 0. Since smart servos are intended to be daisy chained, in order to respond differently from one another, the user must set different identification numbers. Servos with the same ID and baud rate will all receive and react to the same commands.
365
366 Query Identification (**QID**)
367
368 EX: #QID<cr> might return *QID5<cr>
369
370 When using the query ID command, it is best to only have one servo connected and thus receive only one reply.
371
372 Configure ID (**CID**)
373
374 Ex: #CID5<cr>
375
376 Setting a servo's ID in EEPROM is done via the CID command. All servos connected to the same serial bus will be assigned that ID. In most situations each servo must be set a unique ID, which means each servo must be connected individually to the serial bus and receive a unique CID number. It is best to do this before the servos are added to an assembly. Numbered stickers are provided to distinguish each servo after their ID is set, though you are free to use whatever alternative method you like.
377
378 __18. Baud Rate__
379
380 A servo's baud rate cannot be set "on the fly" and must be configured via the CB command described below. The factory default baud rate for all servos is 9600. Since smart servos are intended to be daisy chained, in order to respond to the same serial bus, all servos in that project should ideally be set to the same baud rate. Setting different baud rates will have the servos respond differently and may create issues. Available baud rates are: 9.6 kbps, 19.2 kbps, 38.4 kbps, 57.6 kbps, 115.2 kbps, 230.4 kbps, 250.0 kbps, 460.8 kbps, 500.0 kbps, 750.0 kbps*, 921.6 kbps*. Servos are shipped with a baud rate set to 9600. The baud rates are currently restricted to those above.
381 \*: Current tests reveal baud rates above 500 kbps are unstable and can cause timeouts. Please keep this in mind if using those / testing them out.
382
383 Query Baud Rate (**QB**)
384
385 Ex: #5QB<cr> might return *5QB9600<cr>
386
387 Querying the baud rate is used simply to confirm the CB configuration command before the servo is power cycled.
388
389 Configure Baud Rate (**CB**)
390
391 Ex: #5CB9600<cr>
392
393 Sending this command will change the baud rate associated with servo ID 5 to 9600 bits per second.
394
395 __19. Gyre Rotation Direction__
396
397 "Gyre" is defined as a circular course or motion. The effect of changing the gyre direction is as if you were to use a mirror image of a circle. CW = 1; CCW = -1. The factory default is clockwise (CW).
398
399 {images showing before and after with AR and Origin offset}
400
401 Query Gyre Direction (**QG**)
402
403 Ex: #5QG<cr> might return *5QG-1<cr>
404
405 The value returned above means the servo is in a counter-clockwise gyration.
406
407 Configure Gyre (**CG**)
408
409 Ex: #5CG-1<cr>
410
411 This changes the gyre direction as described above and also writes to EEPROM.
412
413 __20. First / Initial Position (pulse)__
414
415 In certain cases, a user might want to have the servo move to a specific angle upon power up. We refer to this as "first position". The factory default has no first position value stored in EEPROM and therefore upon power up, the servo remains limp until a position (or hold command) is assigned. FP and FD are different in that FP is used for RC mode only, whereas FD is used for serial mode only.
416
417 Query First Position in Pulses (**QFP**)
418
419 Ex: #5QFP<cr> might return *5QFP1550<cr>
420
421 The reply above indicates that servo with ID 5 has a first position pulse of 1550 microseconds.
422
423 Configure First Position in Pulses (CFP)
424
425 Ex: #5CP1550<cr>
426
427 This configuration command means the servo, when set to RC mode, will immediately move to an angle equivalent to having received an RC pulse of 1550 microseconds upon power up. Sending a CFP command without a number results in the servo remaining limp upon power up.
428
429 __21. First / Initial Position (Degrees)__
430
431 In certain cases, a user might want to have the servo move to a specific angle upon power up. We refer to this as "first position". The factory default has no first position value stored in EEPROM and therefore upon power up, the servo remains limp until a position (or hold command) is assigned. FP and FD are different in that FP is used for RC mode only, whereas FD is used for serial mode only.
432
433 Query First Position in Degrees (**QFD**)
434
435 Ex: #5QFD<cr> might return *5QFD64<cr>
436
437 The reply above indicates that servo with ID 5 has a first position pulse of 1550 microseconds.
438
439 Configure First Position in Degrees (**CFD**)
440
441 Ex: #5CD64<cr>
442
443 This configuration command means the servo, when set to serial mode, will immediately move to 6.4 degrees upon power up. Sending a CFD command without a number results in the servo remaining limp upon power up.
444
445 __22. Query Target Position in Degrees (**QDT**)__
446
447 Ex: #5QDT<cr> might return *5QDT6783<cr>
448
449 The query target position command returns the target angle during and after an action which results in a rotation of the servo horn. In the example above, the servo is rotating to a virtual position of 678.3 degrees. Should the servo not have a target position or be in wheel mode, it will respond without a number (Ex: *5QDT<cr>).
450
451 __23. Query Model (**QM**)__
452
453 Ex: #5QM<cr> might return *5QM11<cr>
454
455 This reply means the servo model is 1.1, meaning high speed servo, first revision. 1=HS (high speed) 2=ST (standard) 3=HT (high torque)
456
457 __24. Query Serial Number (**QN**)__
458
459 Ex: #5QN<cr> might return *5QN~_~_<cr>
460
461 The number in the response is the servo's serial number which is set and cannot be changed.
462
463 __25. Query Firmware (**QF**)__
464
465 Ex: #5QF<cr> might return *5QF11<cr>
466
467 The integer in the reply represents the firmware version with one decimal, in this example being 1.1
468
469 __26. Query Status (**Q**)__
470
471 Ex: #5Q<cr> might return *5Q_<cr>
472
473 {Description coming soon}
474
475 __27. Query Voltage (**QV**)__
476
477 Ex: #5QV<cr> might return *5QV112<cr>
478
479 The number returned has one decimal, so in the case above, servo with ID 5 has an input voltage of 11.2V (perhaps a three cell LiPo battery).
480
481 __28. Query Temperature (**QT**)__
482
483 Ex: #5QT<cr> might return *5QT564<cr>
484
485 The units are in tenths of degrees Celcius, so in the example above, the servo's internal temperature is 56.4 degrees C. To convert from degrees Celcius to degrees Farenheit, multiply by 1.8 and add 32. Therefore 56.4C = 133.52F.
486
487 __29. Query Current (QC)__
488
489 Ex: #5QC<cr> might return *5QC140<cr>
490
491 The units are in milliamps, so in the example above, the servo is consuming 140mA, or 0.14A.
492
493 __**RESET**__
494
495 Ex: #5RESET<cr> or #5RS<cr>
496
497 This command does a "soft reset" (no power cycle required) and reverts all commands to those stored in EEPROM (i.e. configuration commands).
498
499 **__DEFAULT __**__& **CONFIRM**__
500
501 Ex: #5DEFAULT<cr>
502
503 This command sets in motion the reset all values to the default values included with the version of the firmware installed on that servo. The servo then waits for the CONFIRM command. Any other command received will cause the servo to exit the DEFAULT function.
504
505 EX: #5DEFAULT<cr> followed by #5CONFIRM<cr>
506
507 Since it it not common to have to restore all configurations, a confirmation command is needed after a firmware command is sent. Should any command other than CONFIRM be received by the servo after the firmware command has been received, it will leave the firmware action.
508
509 Note that after the CONFIRM command is sent, the servo will automatically perform a RESET.
510
511 **__UPDATE __**__& **CONFIRM**__
512
513 Ex: #5UPDATE<cr>
514
515 This command sets in motion the equivalent of a long button press when the servo is not powered in order to enter firmware update mode. This is useful should the button be broken or inaccessible. The servo then waits for the CONFIRM command. Any other command received will cause the servo to exit the UPDATE function.
516
517 EX: #5UPDATE<cr> followed by #5CONFIRM<cr>
518
519 Since it it not common to have to update firmware, a confirmation command is needed after an UPDATE command is sent. Should any command other than CONFIRM be received by the servo after the firmware command has been received, it will leave the firmware action.
520
521 Note that after the CONFIRM command is sent, the servo will automatically perform a RESET.
522
523 === Virtual Angular Position ===
524
525 {In progress}
526
527 A "virtual position" is one which allows for multiple rotations of the output horn, moving the center position and more. The "absolute position" would be the angle of the output shaft with respect to 360.0 degrees.
528
529 [[image:LSS-servo-positions.jpg]]
530
531 Example: Gyre direction / rotation is positive (clockwise), and origin offset has not been modified.
532
533 #1D-300<cr> The servo is commander to move to -30.0 degrees (green arrow)
534
535 #1D2100<cr> This second position command is sent to the servo, which moves it to 210.0 degrees (orange arrow)
536
537 #1D-4200<cr> The servo rotates counterclockwise to a position of -420 degrees (red arrow), which means one full rotation of 360 degrees and (420.0-360.0) stopping at an absolute position of 60.0 degrees, but virtual position of -420.0.
538
539 Although the final position would be the same as if the servo were commanded to move to -60.0 degrees, it is in fact at -420.0 degrees.
540
541 #1D4800<cr> This new command is sent which would then cause the servo to rotate from -420.0 degrees to 480.0 degrees, which would be a total of 900 degrees of clockwise rotation, or 2.5 complete rotations.
Copyright RobotShop 2018