Wiki source code of LSS - Communication Protocol

Version 60.1 by Coleman Benson on 2018/09/24 10:45

Show last authors
1 The Lynxmotion Smart Servo (LSS) protocol was created in order to be as simple and straightforward as possible from a user perspective, while at the same time trying to stay compact and robust yet highly versatile. Almost everything one might expect to be able to configure for a smart servo motor is available.
2
3 === Session ===
4
5 A "session" is defined as the time between when the servo is powered ON to when it is powered OFF or reset.
6
7 == Action Commands ==
8
9 Action commands are sent serially to the servo's Rx pin and must be set in the following format:
10
11 1. Start with a number sign # (U+0023)
12 1. Servo ID number as an integer
13 1. Action command (one to three letters, no spaces, capital or lower case)
14 1. Action value in the correct units with no decimal
15 1. End with a control / carriage return '<cr>'
16
17 (((
18 Ex: #5PD1443<cr>
19
20 Move servo with ID #5 to a position of 144.3 degrees.
21
22 Action commands cannot be combined with query commands, and only one action command can be sent at a time.
23
24 Action commands are session-specific, therefore once a servo is power cycled, it will not have any "memory" of previous actions or virtual positions (as described at the bottom of this page).
25
26 === Action Modifiers ===
27
28 Two commands can be used as action modifiers only: Timed Move and Speed. The format is:
29
30 1. Start with a number sign # (U+0023)
31 1. Servo ID number as an integer
32 1. Action command (one to three letters, no spaces, capital or lower case)
33 1. Action value in the correct units with no decimal
34 1. Modifier command (one letter)
35 1. Modifier value in the correct units with no decimal
36 1. End with a control / carriage return '<cr>'
37
38 Ex: #5P1456T1263<cr>
39
40 Results in the servo rotating from the current angular position to a pulse position of 1456 in 1263 milliseconds.
41
42 Action modifiers can only be used with certain commands.
43 )))
44
45 (((
46
47 )))
48
49 == Configuration Commands ==
50
51 Configuration commands affect the servo's current session* but unlike action commands, configuration commands are written to EEPROM and are retained even if the servo loses power (therefore NOT session specific). Not all action commands have a corresponding configuration and vice versa. Certain configurations are retained for when the servo is used in RC model. More information can be found on the [[LSS - RC PWM page>>doc:LSS - Overview (DEV).LSS - RC PWM.WebHome]].
52
53 1. Start with a number sign # (U+0023)
54 1. Servo ID number as an integer
55 1. Configuration command (two to three letters, no spaces, capital or lower case)
56 1. Configuration value in the correct units with no decimal
57 1. End with a control / carriage return '<cr>'
58
59 Ex: #5CO-50<cr>
60
61 Assigns an absolute origin offset of -5.0 degrees (with respect to factory origin) to servo #5 and changes the offset for that session to -5.0 degrees.
62
63 Configuration commands are not cumulative, in that if two configurations are sent at any time, only the last configuration is used and stored.
64
65 *Important Note: the one exception is the baud rate - the servo's current session retains the given baud rate. The new baud rate will only be in place when the servo is power cycled.
66
67 == Query Commands ==
68
69 Query commands are sent serially to the servo's Rx pin and must be set in the following format:
70
71 1. Start with a number sign # (U+0023)
72 1. Servo ID number as an integer
73 1. Query command (one to three letters, no spaces, capital or lower case)
74 1. End with a control / carriage return '<cr>'
75
76 (((
77 Ex: #5QD<cr>Query position in degrees for servo #5
78 )))
79
80 (((
81 The query will return a value via the Tx pin with the following format:
82
83 1. Start with an asterisk (U+002A)
84 1. Servo ID number as an integer
85 1. Query command (one to three letters, no spaces, capital letters)
86 1. The reported value in the units described, no decimals.
87 1. End with a control / carriage return '<cr>'
88
89 (((
90 Ex: *5QD1443<cr>
91 )))
92
93 Indicates that servo #5 is currently at 144.3 degrees.
94
95 **Session vs Configuration Query**
96
97 By default, the query command returns the sessions' value; should no action commands have been sent to change, it will return the value saved in EEPROM from the last configuration command.
98
99 In order to query the value in EEPROM, add a '1' to the query command.
100
101 Ex: #5CSR20<cr> sets the maximum speed for servo #5 to 20rpm upon RESET (explained below).
102
103 After RESET: #5SR4<cr> sets the session's speed to 4rpm.
104
105 #5QSR<cr> would return *5QSR4<cr> which represents the value for that session.
106
107 #5QSR1<cr> would return *5QSR20<cr> which represents the value in EEPROM
108
109 === Virtual Angular Position ===
110
111 {In progress}
112
113 A "virtual position" is one which allows for multiple rotations of the output horn, moving the center position and more. The "absolute position" would be the angle of the output shaft with respect to 360.0 degrees.
114
115 [[image:LSS-servo-positions.jpg]]
116
117 Example: Gyre direction / rotation is positive (clockwise), and origin offset has not been modified. Each square represents 30 degrees.
118
119 #1D-300<cr> The servo is sent a command to move to -30.0 degrees (green arrow)
120
121 #1D2100<cr> This second position command is sent to the servo, which moves it to 210.0 degrees (orange arrow)
122
123 #1D-4200<cr> This next command rotates the servo counterclockwise to a position of -420 degrees (red arrow), which means one full rotation of 360 degrees,  stopping at an absolute position of 60.0 degrees (420.0-360.0), with a virtual position of -420.0 degrees.
124
125 Although the final physical position would be the same as if the servo were commanded to move to -60.0 degrees, the servo is in fact at -420.0 degrees.
126
127 #1D4800<cr> This new command is sent which would then cause the servo to rotate from -420.0 degrees to 480.0 degrees (blue arrow), which would be a total of 900 degrees of clockwise rotation, or 2.5 complete rotations.
128
129 #1D3300<cr> would cause the servo to rotate from 480.0 degrees to 330.0 degrees (yellow arrow).
130
131 If / once the servo loses power or is power cycled, it also loses the virtual position associated with that session. For example, if the virtual position was 480.0 degrees before power is cycled, upon power up the servo's position will be read as +120.0 degrees from zero (assuming center position has not been modified).
132 )))
133
134 = Command List =
135
136 |= #|=Description|= Action|= Query|= Config|= RC|= Serial|= Units|= Notes
137 | 1|**L**imp| L| | | | ✓| none|
138 | 2|**H**alt & Hold| H| | | | ✓| none|
139 | 3|**T**imed move| T| | | | ✓| milliseconds| Modifier only
140 | 4|**S**peed| S| | | | ✓| microseconds / second| Modifier only
141 | 5|**M**ove in **D**egrees (relative)| MD| | | | ✓| tenths of degrees (ex 325 = 32.5 degrees; 91 = 9.1 degrees)|
142 | 6|**O**rigin Offset| O| QO| CO| ✓| ✓| tenths of degrees (ex 325 = 32.5 degrees; 91 = 9.1 degrees)|
143 | 7|**A**ngular **R**ange| AR| QAR| CAR| ✓| ✓| tenths of degrees (ex 325 = 32.5 degrees; 91 = 9.1 degrees)|
144 | 8|Position in **P**ulse| P| QP| | | ✓| microseconds|(((
145 See details below
146 )))
147 | 9|Position in **D**egrees| D| QD| | | ✓| tenths of degrees (ex 325 = 32.5 degrees; 91 = 9.1 degrees)|
148 | 10|**W**heel mode in **D**egrees| WD| QWD| | | ✓| tenths of degrees per second (ex 248 = 24.8 degrees per second)|
149 | 11|**W**heel mode in **R**PM| WR| QWR| | | ✓| rpm|
150 | 12|Max **S**peed in **D**egrees| SD| QSD| CSD| ✓| ✓| tenths of degrees per second (ex 248 = 24.8 degrees per second)|QSD: Add modifier "2" for instantaneous speed
151 | 13|Max **S**peed in **R**PM| SR| QSR| CSR| ✓| ✓| rpm|QSR: Add modifier "2" for instantaneous speed
152 | 14|**A**ngular **S**tiffness| AS| QAS| CAS| ✓| ✓|none|-4 to +4, but suggested values are between 0 to +4
153 | 15|//N/A (removed)//| | | | | | |
154 | 16|**LED** Color| LED| QLED| CLED| ✓| ✓| none (integer from 1 to 8)|0=OFF 1=RED 2=GREEN 3= BLUE 4=YELLOW 5=CYAN 6=MAGENTA, 7=WHITE
155 | 17|**ID** #| | QID| CID| | ✓| none (integer from 0 to 250)|Note: ID 254 is a "broadcast" which all servos respond to
156 | 18|**B**aud rate| B| QB| CB| | ✓| none (integer)|
157 | 19|**G**yre direction (**G**)| G| QG| CG| ✓| ✓| none | Gyre / rotation direction where 1= CW (clockwise) -1 = CCW (counter-clockwise)
158 | 20|**F**irst Position (**P**ulse)| | QFP|CFP | ✓| ✓| none |
159 | 21|**F**irst Position (**D**egrees)| | QFD|CFD| ✓| ✓| none |
160 | 22|**T**arget (**D**egree) **P**osition| | QDT| | | ✓| tenths of degrees (ex 325 = 32.5 degrees; 91 = 9.1 degrees)|
161 | 23|**M**odel| | QM| | | | none (integer)|
162 | 24|Serial **N**umber| | QN| | | | none (integer)|
163 | 25|**F**irmware version| | QF| | | | none (integer)|
164 | 26|**Q**uery (general status)| | Q| | | ✓| none (integer from 1 to 8)| See command description for details
165 | 27|**V**oltage| | QV| | | ✓| millivolts (ex 5936 = 5936mV = 5.936V)|
166 | 28|**T**emperature| | QT| | | ✓| tenths of degrees Celsius|Max temp before error: 85°C (servo goes limp)
167 | 29|**C**urrent| | QC| | | ✓| tenths of Amps (ex 2 = 0.2A)|
168 | 30|**RC** Mode| | |CRC| |✓|none|(((
169 CRC: Add modifier "1" for RC-position mode.
170 CRC: Add modifier "2" for RC-wheel mode.
171 Any other value for the modifier results in staying in smart mode.
172 Puts the servo into RC mode. To revert to smart mode, use the button menu.
173 )))
174 |31|**RESET**| | | | | ✓|none|Soft reset. See command for details.
175 |32|**DEFAULT**| | | | |✓|none|Revert to firmware default values. See command for details
176 |33|**UPDATE**| | | | |✓|none|Update firmware. See command for details.
177
178 = Details =
179
180 __1. Limp (**L**)__
181
182 Example: #5L<cr>
183
184 This action causes the servo to go "limp". The microcontroller will still be powered, but the motor will not. As an emergency safety feature, should the robot not be doing what it is supposed to or risks damage, use the broadcast ID to set all servos limp #254L<cr>.
185
186 __2. Halt & Hold (**H**)__
187
188 Example: #5H<cr>
189
190 This action overrides whatever the servo might be doing at the time the command is received (accelerating, moving continuously etc.) and causes it to stop immediately and hold that position.
191
192 __3. Timed move (**T**)__
193
194 Example: #5P1500T2500<cr>
195
196 Timed move can be used only as a modifier for a position (P) action. The units are in milliseconds, so a timed move of 2500 milliseconds would cause the servo to rotate from its current position to the desired position in 2.5 seconds. This command is in place to ensure backwards compatibility with the SSC-32 / 32U protocol.
197
198 __4. Speed (**S**)__
199
200 Example: #5P1500S750<cr>
201
202 This command is a modifier only for a position (P) action and determines the speed of the move in microseconds per second. A speed of 750 microseconds would cause the servo to rotate from its current position to the desired position at a speed of 750 microseconds per second. This command is in place to ensure backwards compatibility with the SSC-32 / 32U protocol.
203
204 __5. (Relative) Move in Degrees (**MD**)__
205
206 Example: #5MD123<cr>
207
208 The relative move command causes the servo to read its current position and move the specified number of tenths of degrees in the corresponding position. For example if the servo is set to rotate CW (default) and an MD command of 123 is sent to the servo, it will cause the servo to rotate clockwise by 12.3 degrees. Negative commands would cause the servo to rotate in the opposite configured direction.
209
210 __6. Origin Offset Action (**O**)__
211
212 Example: #5O2400<cr>
213
214 This command allows you to temporarily change the origin of the servo in relation to the factory zero position. The setting will be lost upon servo reset / power cycle. Origin offset commands are not cumulative and always relate to factory zero. Note that for a given session, the O command overrides the CO command. In the first image, the origin at factory offset '0' (centered).
215
216 [[image:LSS-servo-default.jpg]]
217
218 In the second image, the origina, as well as the angular range (explained below) have been shifted by 240.0 degrees:
219
220 [[image:LSS-servo-origin.jpg]]
221
222 Origin Offset Query (**QO**)
223
224 Example: #5QO<cr> Returns: *5QO-13
225
226 This allows you to query the angle (in tenths of degrees) of the origin in relation to the factory zero position.
227
228 Configure Origin Offset (**CO**)
229
230 Example: #5CO-24<cr>
231
232 This command allows you to change the origin of the servo in relation to the factory zero position in EEPROM. The setting will be saved upon servo reset / power cycle. Origin offset configuration commands are not cumulative and always relate to factory zero. The new origin is also used in RC mode.
233
234 __7. Angular Range (**AR**)__
235
236 Example: #5AR1800<cr>
237
238 This command allows you to temporarily change the total angular range of the servo in tenths of degrees. This applies to the Position in Pulse (P) command and RC mode. The default for (P) and RC mode is 1800 (180.0 degrees total, or ±90.0 degrees). In the first image,
239
240 [[image:LSS-servo-default.jpg]]
241
242 Here, the angular range has been restricted to 180.0 degrees, or -90.0 to +90.0. The center has remained unchanged.
243
244 [[image:LSS-servo-ar.jpg]]
245
246 The angular range action command (ex. #5AR1800<cr>) and origin offset action command (ex. #5O-1200<cr>) an be used to move both the center and limit the angular range:
247
248 [[image:LSS-servo-ar-o-1.jpg]]
249
250 Query Angular Range (**QAR**)
251
252 Example: #5QAR<cr> might return *5AR2756
253
254 Configure Angular Range (**CAR**)
255
256 This command allows you to change the total angular range of the servo in tenths of degrees in EEPROM. The setting will be saved upon servo reset / power cycle.
257
258 __8. Position in Pulse (**P**)__
259
260 Example: #5P2334<cr>
261
262 The position in PWM pulses was retained in order to be backward compatible with the SSC-32 / 32U protocol. This relates the desired angle with an RC standard PWM pulse and is further explained in the SSC-32 and SSC-32U manuals found on Lynxmotion.com. Without any modifications to configuration considered, and a ±90.0 degrees standard range where 1500 microseconds is centered, a pulse of 2334 would set the servo to 165.1 degrees. Valid values for P are [500, 2500]. Values outside this range are corrected to end points.
263
264 Query Position in Pulse (**QP**)
265
266 Example: #5QP<cr> might return *5QP2334
267
268 This command queries the current angular position in PWM "units". The user must take into consideration that the response includes any angular range and origin configurations in order to determine the actual angle. 
269 Valid values for QP are {-500, [500, 2500], -2500}. Values outside the [500, 2500] range are given a negative corresponding end point value to indicate they are out of bounds (note that if the servo is physically located at one of the endpoints, it may return a negative number if it is a fraction of a degree beyond the position).
270
271 __9. Position in Degrees (**D**)__
272
273 Example: #5PD1456<cr>
274
275 This moves the servo to an angle of 145.6 degrees, where the center (0) position is centered. Negative values (ex. -176 representing -17.6 degrees) are used. A full circle would be from -1800 to 1800 degrees. A value of 2700 would be the same angle as -900, except the servo would move in a different direction.
276
277 Larger values are permitted and allow for multi-turn functionality using the concept of virtual position.
278
279 Query Position in Degrees (**QD**)
280
281 Example: #5QD<cr> might return *5QD132<cr>
282
283 This means the servo is located at 13.2 degrees.
284
285 __10. Wheel Mode in Degrees (**WD**)__
286
287 Ex: #5WD900<cr>
288
289 This command sets the servo to wheel mode where it will rotate in the desired direction at the selected speed. The example above would have the servo rotate at 90.0 degrees per second clockwise (assuming factory default configurations).
290
291 Query Wheel Mode in Degrees (**QWD**)
292
293 Ex: #5QWD<cr> might return *5QWD900<cr>
294
295 The servo replies with the angular speed in tenths of degrees per second. A negative sign would indicate the opposite direction (for factory default a negative value would be counter clockwise).
296
297 __11. Wheel Mode in RPM (**WR**)__
298
299 Ex: #5WR40<cr>
300
301 This command sets the servo to wheel mode where it will rotate in the desired direction at the selected rpm. Wheel mode (a.k.a. "continuous rotation") has the servo operate like a geared DC motor. The servo's maximum rpm cannot be set higher than its physical limit at a given voltage. The example above would have the servo rotate at 40 rpm clockwise (assuming factory default configurations).
302
303 Query Wheel Mode in RPM (**QWR**)
304
305 Ex: #5QWR<cr> might return *5QWR40<cr>
306
307 The servo replies with the angular speed in rpm. A negative sign would indicate the opposite direction (for factory default a negative value would be counter clockwise).
308
309 __12. Speed in Degrees (**SD**)__
310
311 Ex: #5SD1800<cr>
312
313 This command sets the servo's maximum speed for action commands in tenths of degrees per second for that session. In the example above, the servo's maximum speed for that session would be set to 180.0 degrees per second. Therefore maximum speed for actions can be set "on the fly". The servo's maximum speed cannot be set higher than its physical limit at a given voltage. SD overrides CSD (described below) for that session. Upon reset or power cycle, the servo reverts to the value associated with CSD as described below. Note that SD and SR (described below) are effectively the same, but allow the user to specify the speed in either unit. The last command (either SR or SD) is what the servo uses for that session.
314
315 Query Speed in Degrees (**QSD**)
316
317 Ex: #5QSD<cr> might return *5QSD1800<cr>
318
319 By default QSD will return the current session value, which is set to the value of CSD as reset/power cycle and changed whenever a SD/SR command is processed.
320 If #5QSD1<cr> is sent, the configured maximum speed (CSD value) will be returned instead. You can also query the current speed using "2" and the current target travel speed using "3". See the table below for an example:
321
322 |**Command sent**|**Returned value (1/10 °)**
323 |ex: #5QSD<cr>|Session value for maximum speed (set by latest SD/SR command)
324 |ex: #5QSD1<cr>|Configured maximum speed  (set by CSD/CSR)
325 |ex: #5QSD2<cr>|Instantaneous speed (same as QWD)
326 |ex: #5QSD3<cr>|Target travel speed
327
328 Configure Speed in Degrees (**CSD**)
329
330 Ex: #5CSD1800<cr>
331
332 Using the CSD command sets the servo's maximum speed which is saved in EEPROM. In the example above, the servo's maximum speed will be set to 180.0 degrees per second. When the servo is powered on (or after a reset), the CSD value is used. Note that CSD and CSR (described below) are effectively the same, but allow the user to specify the speed in either unit. The last command (either CSR or CSD) is what the servo uses for that session.
333
334 __13. Speed in RPM (**SR**)__
335
336 Ex: #5SD45<cr>
337
338 This command sets the servo's maximum speed for action commands in rpm for that session. In the example above, the servo's maximum speed for that session would be set to 45rpm. Therefore maximum speed for actions can be set "on the fly". The servo's maximum speed cannot be set higher than its physical limit at a given voltage. SD overrides CSD (described below) for that session. Upon reset or power cycle, the servo reverts to the value associated with CSD as described below. Note that SD (described above) and SR are effectively the same, but allow the user to specify the speed in either unit. The last command (either SR or SD) is what the servo uses for that session.
339
340 Query Speed in Degrees (**QSR**)
341
342 Ex: #5QSR<cr> might return *5QSR45<cr>
343
344 By default QSR will return the current session value, which is set to the value of CSR as reset/power cycle and changed whenever a SD/SR command is processed.
345 If #5QSR1<cr> is sent, the configured maximum speed (CSR value) will be returned instead. You can also query the current speed using "2" and the current target travel speed using "3". See the table below for an example:
346
347 |**Command sent**|**Returned value (1/10 °)**
348 |ex: #5QSR<cr>|Session value for maximum speed (set by latest SD/SR command)
349 |ex: #5QSR1<cr>|Configured maximum speed  (set by CSD/CSR)
350 |ex: #5QSR2<cr>|Instantaneous speed (same as QWR)
351 |ex: #5QSR3<cr>|Target travel speed
352
353 Configure Speed in RPM (**CSR**)
354
355 Ex: #5CSR45<cr>
356
357 Using the CSR command sets the servo's maximum speed which is saved in EEPROM. In the example above, the servo's maximum speed will be set to 45rpm. When the servo is powered on (or after a reset), the CSR value is used. Note that CSD and CSR are effectively the same, but allow the user to specify the speed in either unit. The last command (either CSR or CSD) is what the servo uses for that session.
358
359 __14. Angular Stiffness (AS)__
360
361 The servo's rigidity / angular stiffness can be thought of as (though not identical to) a damped spring in which the value affects the stiffness and embodies how much, and how quickly the servo tried keep the requested position against changes.
362
363 A positive value of "angular stiffness":
364
365 * The more torque will be applied to try to keep the desired position against external input / changes
366 * The faster the motor will reach its intended travel speed and the motor will decelerate faster and nearer to its target position
367
368 A negative value on the other hand:
369
370 * Causes a slower acceleration to the travel speed, and a slower deceleration
371 * Allows the target position to deviate more from its position before additional torque is applied to bring it back
372
373 The default value is zero and the effect becomes extreme by -4, +4. There are no units, only integers between -4 to 4. Greater values produce increasingly erratic behavior.
374
375 Ex: #5AS-2<cr>
376
377 This reduces the angular stiffness to -2 for that session, allowing the servo to deviate more around the desired position. This can be beneficial in many situations such as impacts (legged robots) where more of a "spring" effect is desired. Upon reset, the servo will use the value stored in memory, based on the last configuration command.
378
379 Ex: #5QAS<cr>
380
381 Queries the value being used.
382
383 Ex: #5CAS<cr>
384
385 Writes the desired angular stiffness value to memory.
386
387 __15. N/A (removed)__
388
389 This command has been removed.
390
391 __16. RGB LED (**LED**)__
392
393 Ex: #5LED3<cr>
394
395 This action sets the servo's RGB LED color for that session.The LED can be used for aesthetics, or (based on user code) to provide visual status updates. Using timing can create patterns.
396
397 0=OFF 1=RED 2=GREEN 3= BLUE 4=YELLOW 5=CYAN 6= 7=MAGENTA, 8=WHITE 
398
399 Query LED Color (**QLED**)
400
401 Ex: #5QLED<cr> might return *5QLED5<cr>
402
403 This simple query returns the indicated servo's LED color.
404
405 Configure LED Color (**CLED**)
406
407 Configuring the LED color via the CLED command sets the startup color of the servo after a reset or power cycle. Note that it also changes the session's LED color immediately as well.
408
409 __17. Identification Number__
410
411 A servo's identification number cannot be set "on the fly" and must be configured via the CID command described below. The factory default ID number for all servos is 0. Since smart servos are intended to be daisy chained, in order to respond differently from one another, the user must set different identification numbers. Servos with the same ID and baud rate will all receive and react to the same commands.
412
413 Query Identification (**QID**)
414
415 EX: #254QID<cr> might return *QID5<cr>
416
417 When using the query ID command, it is best to only have one servo connected and thus receive only one reply using the broadcast command (ID 254). Alternatively, pushing the button upon startup and temporarily setting the servo ID to 255 will still result in the servo responding with its "real" ID.
418
419 Configure ID (**CID**)
420
421 Ex: #4CID5<cr>
422
423 Setting a servo's ID in EEPROM is done via the CID command. All servos connected to the same serial bus will be assigned that ID. In most situations each servo must be set a unique ID, which means each servo must be connected individually to the serial bus and receive a unique CID number. It is best to do this before the servos are added to an assembly. Numbered stickers are provided to distinguish each servo after their ID is set, though you are free to use whatever alternative method you like.
424
425 __18. Baud Rate__
426
427 A servo's baud rate cannot be set "on the fly" and must be configured via the CB command described below. The factory default baud rate for all servos is 9600. Since smart servos are intended to be daisy chained, in order to respond to the same serial bus, all servos in that project should ideally be set to the same baud rate. Setting different baud rates will have the servos respond differently and may create issues. Available baud rates are: 9.6 kbps, 19.2 kbps, 38.4 kbps, 57.6 kbps, 115.2 kbps, 230.4 kbps, 250.0 kbps, 460.8 kbps, 500.0 kbps, 750.0 kbps*, 921.6 kbps*. Servos are shipped with a baud rate set to 9600. The baud rates are currently restricted to those above.
428 \*: Current tests reveal baud rates above 500 kbps are unstable and can cause timeouts. Please keep this in mind if using those / testing them out.
429
430 Query Baud Rate (**QB**)
431
432 Ex: #5QB<cr> might return *5QB9600<cr>
433
434 Querying the baud rate is used simply to confirm the CB configuration command before the servo is power cycled.
435
436 Configure Baud Rate (**CB**)
437
438 Ex: #5CB9600<cr>
439
440 Sending this command will change the baud rate associated with servo ID 5 to 9600 bits per second.
441
442 __19. Gyre Rotation Direction__
443
444 "Gyre" is defined as a circular course or motion. The effect of changing the gyre direction is as if you were to use a mirror image of a circle. CW = 1; CCW = -1. The factory default is clockwise (CW).
445
446 {images showing before and after with AR and Origin offset}
447
448 Query Gyre Direction (**QG**)
449
450 Ex: #5QG<cr> might return *5QG-1<cr>
451
452 The value returned above means the servo is in a counter-clockwise gyration.
453
454 Configure Gyre (**CG**)
455
456 Ex: #5CG-1<cr>
457
458 This changes the gyre direction as described above and also writes to EEPROM.
459
460 __20. First / Initial Position (pulse)__
461
462 In certain cases, a user might want to have the servo move to a specific angle upon power up. We refer to this as "first position". The factory default has no first position value stored in EEPROM and therefore upon power up, the servo remains limp until a position (or hold command) is assigned. FP and FD are different in that FP is used for RC mode only, whereas FD is used for smart mode only.
463
464 Query First Position in Pulses (**QFP**)
465
466 Ex: #5QFP<cr> might return *5QFP1550<cr>
467
468 The reply above indicates that servo with ID 5 has a first position pulse of 1550 microseconds. If no first position has been set, servo will respond with DIS ("disabled").
469
470 Configure First Position in Pulses (**CFP**)
471
472 Ex: #5CP1550<cr>
473
474 This configuration command means the servo, when set to RC mode, will immediately move to an angle equivalent to having received an RC pulse of 1550 microseconds upon power up. Sending a CFP command without a number results in the servo remaining limp upon power up (i.e. disabled).
475
476 __21. First / Initial Position (Degrees)__
477
478 In certain cases, a user might want to have the servo move to a specific angle upon power up. We refer to this as "first position". The factory default has no first position value stored in EEPROM and therefore upon power up, the servo remains limp until a position (or hold command) is assigned. FP and FD are different in that FP is used for RC mode only, whereas FD is used for smart mode only.
479
480 Query First Position in Degrees (**QFD**)
481
482 Ex: #5QFD<cr> might return *5QFD64<cr>
483
484 The reply above indicates that servo with ID 5 has a first position pulse of 1550 microseconds.
485
486 Configure First Position in Degrees (**CFD**)
487
488 Ex: #5CD64<cr>
489
490 This configuration command means the servo, when set to smart mode, will immediately move to 6.4 degrees upon power up. Sending a CFD command without a number results in the servo remaining limp upon power up.
491
492 __22. Query Target Position in Degrees (**QDT**)__
493
494 Ex: #5QDT<cr> might return *5QDT6783<cr>
495
496 The query target position command returns the target angle during and after an action which results in a rotation of the servo horn. In the example above, the servo is rotating to a virtual position of 678.3 degrees. Should the servo not have a target position or be in wheel mode, it will respond without a number (Ex: *5QDT<cr>).
497
498 __23. Query Model (**QM**)__
499
500 Ex: #5QM<cr> might return *5QM11<cr>
501
502 This reply means the servo model is 1.1, meaning high speed servo, first revision. 1=HS (high speed) 2=ST (standard) 3=HT (high torque)
503
504 __24. Query Serial Number (**QN**)__
505
506 Ex: #5QN<cr> might return *5QN~_~_<cr>
507
508 The number in the response is the servo's serial number which is set and cannot be changed.
509
510 __25. Query Firmware (**QF**)__
511
512 Ex: #5QF<cr> might return *5QF11<cr>
513
514 The integer in the reply represents the firmware version with one decimal, in this example being 1.1
515
516 __26. Query Status (**Q**)__
517
518 Ex: #5Q<cr> might return *5Q6<cr>, which indicates the motor is holding a position.
519
520 |*Value returned|**Status**|**Detailed description**
521 |ex: *5Q0<cr>|Unknown|LSS is unsure
522 |ex: *5Q1<cr>|Limp|Motor driving circuit is not powered and horn can be moved freely
523 |ex: *5Q2<cr>|Free moving|Motor driving circuit is not powered and horn can be moved freely
524 |ex: *5Q3<cr>|Accelerating|Increasing speed from rest (or previous speeD) towards travel speed
525 |ex: *5Q4<cr>|Traveling|Moving at a stable speed
526 |ex: *5Q5<cr>|Deccelerating|Decreasing speed towards travel speed towards rest
527 |ex: *5Q6<cr>|Holding|Keeping current position
528 |ex: *5Q7<cr>|Stepping|Special low speed mode to maintain torque
529 |ex: *5Q8<cr>|Outside limits|More details coming soon
530 |ex: *5Q9<cr>|Stuck|Motor cannot perform request movement at current speed setting
531 |ex: *5Q10<cr>|Blocked|Similar to stuck, but the motor is at maxiumum duty and still cannot move (i.e.: stalled)
532
533 __27. Query Voltage (**QV**)__
534
535 Ex: #5QV<cr> might return *5QV11200<cr>
536
537 The number returned has one decimal, so in the case above, servo with ID 5 has an input voltage of 11.2V (perhaps a three cell LiPo battery).
538
539 __28. Query Temperature (**QT**)__
540
541 Ex: #5QT<cr> might return *5QT564<cr>
542
543 The units are in tenths of degrees Celcius, so in the example above, the servo's internal temperature is 56.4 degrees C. To convert from degrees Celcius to degrees Farenheit, multiply by 1.8 and add 32. Therefore 56.4C = 133.52F.
544
545 __29. Query Current (**QC**)__
546
547 Ex: #5QC<cr> might return *5QC140<cr>
548
549 The units are in milliamps, so in the example above, the servo is consuming 140mA, or 0.14A.
550
551 __30. RC Mode (**CRC**)__
552
553 This command puts the servo into RC mode (position or continuous), where it will only respond to RC pulses. Note that because this is the case, the servo will no longer accept serial commands. The servo can be placed back into smart mode by using the button menu.
554
555 |**Command sent**|**Note**
556 |ex: #5CRC<cr>|Stay in smart mode.
557 |ex: #5CRC1<cr>|Change to RC position mode.
558 |ex: #5CRC2<cr>|Change to RC continuous (wheel) mode.
559 |ex: #5CRC*<cr>|Where * is any number or value. Stay in smart mode.
560
561 EX: #5CRC<cr>
562
563 __31. RESET__
564
565 Ex: #5RESET<cr> or #5RS<cr>
566
567 This command does a "soft reset" (no power cycle required) and reverts all commands to those stored in EEPROM (i.e. configuration commands).
568
569 __32. DEFAULT & CONFIRM__
570
571 Ex: #5DEFAULT<cr>
572
573 This command sets in motion the reset all values to the default values included with the version of the firmware installed on that servo. The servo then waits for the CONFIRM command. Any other command received will cause the servo to exit the DEFAULT function.
574
575 EX: #5DEFAULT<cr> followed by #5CONFIRM<cr>
576
577 Since it it not common to have to restore all configurations, a confirmation command is needed after a firmware command is sent. Should any command other than CONFIRM be received by the servo after the firmware command has been received, it will leave the firmware action.
578
579 Note that after the CONFIRM command is sent, the servo will automatically perform a RESET.
580
581 __33. UPDATE & CONFIRM__
582
583 Ex: #5UPDATE<cr>
584
585 This command sets in motion the equivalent of a long button press when the servo is not powered in order to enter firmware update mode. This is useful should the button be broken or inaccessible. The servo then waits for the CONFIRM command. Any other command received will cause the servo to exit the UPDATE function.
586
587 EX: #5UPDATE<cr> followed by #5CONFIRM<cr>
588
589 Since it it not common to have to update firmware, a confirmation command is needed after an UPDATE command is sent. Should any command other than CONFIRM be received by the servo after the firmware command has been received, it will leave the firmware action.
590
591 Note that after the CONFIRM command is sent, the servo will automatically perform a RESET.
592
593 === ===
Copyright RobotShop 2018