1 The Lynxmotion Smart Servo (LSS) protocol was created in order to be as simple and straightforward as possible from a user perspective, while at the same time trying to stay compact and robust yet highly versatile. Almost everything one might expect to be able to configure for a smart servo motor is available.
2
3 === Session ===
4
5 A "session" is defined as the time between when the servo is powered ON to when it is powered OFF or reset.
6
7 == Action Commands ==
8
9 Action commands are sent serially to the servo's Rx pin and must be set in the following format:
10
11 1. Start with a number sign # (U+0023)
12 1. Servo ID number as an integer
13 1. Action command (one to three letters, no spaces, capital or lower case)
14 1. Action value in the correct units with no decimal
15 1. End with a control / carriage return '<cr>'
16
17 (((
18 Ex: #5PD1443<cr>
19
20 Move servo with ID #5 to a position of 144.3 degrees.
21
22 Action commands cannot be combined with query commands, and only one action command can be sent at a time.
23
24 Action commands are session-specific, therefore once a servo is power cycled, it will not have any "memory" of previous actions or virtual positions (as described at the bottom of this page).
25
26 === Action Modifiers ===
27
28 Two commands can be used as action modifiers only: Timed Move and Speed. The format is:
29
30 1. Start with a number sign # (U+0023)
31 1. Servo ID number as an integer
32 1. Action command (one to three letters, no spaces, capital or lower case)
33 1. Action value in the correct units with no decimal
34 1. Modifier command (one letter)
35 1. Modifier value in the correct units with no decimal
36 1. End with a control / carriage return '<cr>'
37
38 Ex: #5P1456T1263<cr>
39
40 Results in the servo rotating from the current angular position to a pulse position of 1456 in 1263 milliseconds.
41
42 Action modifiers can only be used with certain commands.
43 )))
44
45 == Configuration Commands ==
46
47 Configuration commands affect the servo's current session* but unlike action commands, configuration commands are written to EEPROM and are retained even if the servo loses power (therefore NOT session specific). Not all action commands have a corresponding configuration and vice versa. Certain configurations are retained for when the servo is used in RC model. More information can be found on the [[LSS - RC PWM page>>doc:LSS - Overview (DEV).LSS - RC PWM.WebHome]].
48
49 1. Start with a number sign # (U+0023)
50 1. Servo ID number as an integer
51 1. Configuration command (two to three letters, no spaces, capital or lower case)
52 1. Configuration value in the correct units with no decimal
53 1. End with a control / carriage return '<cr>'
54
55 Ex: #5CO-50<cr>
56
57 Assigns an absolute origin offset of -5.0 degrees (with respect to factory origin) to servo #5 and changes the offset for that session to -5.0 degrees.
58
59 Configuration commands are not cumulative, in that if two configurations are sent at any time, only the last configuration is used and stored.
60
61 *Important Note: the one exception is the baud rate - the servo's current session retains the given baud rate. The new baud rate will only be in place when the servo is power cycled.
62
63 == Query Commands ==
64
65 Query commands are sent serially to the servo's Rx pin and must be set in the following format:
66
67 1. Start with a number sign # (U+0023)
68 1. Servo ID number as an integer
69 1. Query command (one to three letters, no spaces, capital or lower case)
70 1. End with a control / carriage return '<cr>'
71
72 (((
73 Ex: #5QD<cr>Query position in degrees for servo #5
74 )))
75
76 (((
77 The query will return a value via the Tx pin with the following format:
78
79 1. Start with an asterisk (U+002A)
80 1. Servo ID number as an integer
81 1. Query command (one to three letters, no spaces, capital letters)
82 1. The reported value in the units described, no decimals.
83 1. End with a control / carriage return '<cr>'
84
85 (((
86 Ex: *5QD1443<cr>
87 )))
88
89 Indicates that servo #5 is currently at 144.3 degrees.
90
91 **Session vs Configuration Query**
92
93 By default, the query command returns the sessions' value; should no action commands have been sent to change, it will return the value saved in EEPROM from the last configuration command.
94
95 In order to query the value in EEPROM, add a '1' to the query command.
96
97 Ex: #5CSR20<cr> sets the maximum speed for servo #5 to 20rpm upon RESET (explained below).
98
99 After RESET: #5SR4<cr> sets the session's speed to 4rpm.
100
101 #5QSR<cr> would return *5QSR4<cr> which represents the value for that session.
102
103 #5QSR1<cr> would return *5QSR20<cr> which represents the value in EEPROM
104
105 === Virtual Angular Position ===
106
107 {In progress}
108
109 A "virtual position" is one which allows for multiple rotations of the output horn, moving the center position and more. The "absolute position" would be the angle of the output shaft with respect to 360.0 degrees.
110
111 [[image:LSS-servo-positions.jpg]]
112
113 Example: Gyre direction / rotation is positive (clockwise), and origin offset has not been modified. Each square represents 30 degrees.
114
115 #1D-300<cr> The servo is sent a command to move to -30.0 degrees (green arrow)
116
117 #1D2100<cr> This second position command is sent to the servo, which moves it to 210.0 degrees (orange arrow)
118
119 #1D-4200<cr> This next command rotates the servo counterclockwise to a position of -420 degrees (red arrow), which means one full rotation of 360 degrees,  stopping at an absolute position of 60.0 degrees (420.0-360.0), with a virtual position of -420.0 degrees.
120
121 Although the final physical position would be the same as if the servo were commanded to move to -60.0 degrees, the servo is in fact at -420.0 degrees.
122
123 #1D4800<cr> This new command is sent which would then cause the servo to rotate from -420.0 degrees to 480.0 degrees (blue arrow), which would be a total of 900 degrees of clockwise rotation, or 2.5 complete rotations.
124
125 #1D3300<cr> would cause the servo to rotate from 480.0 degrees to 330.0 degrees (yellow arrow).
126
127 If / once the servo loses power or is power cycled, it also loses the virtual position associated with that session. For example, if the virtual position was 480.0 degrees before power is cycled, upon power up the servo's position will be read as +120.0 degrees from zero (assuming center position has not been modified).
128 )))
129
130 = Command List =
131
132 |= #|=Description|= Action|= Query|= Config|= RC|= Serial|= Units|= Notes
133 | 1|**L**imp| L| | | | ✓| none|
134 | 2|**H**alt & Hold| H| | | | ✓| none|
135 | 3|**T**imed move| T| | | | ✓| milliseconds| Modifier only
136 | 4|**S**peed| S| | | | ✓| microseconds / second| Modifier only
137 | 5|**M**ove in **D**egrees (relative)| MD| | | | ✓| tenths of degrees (ex 325 = 32.5 degrees; 91 = 9.1 degrees)|
138 | 6|**O**rigin Offset| O| QO| CO| ✓| ✓| tenths of degrees (ex 325 = 32.5 degrees; 91 = 9.1 degrees)|
139 | 7|**A**ngular **R**ange| AR| QAR| CAR| ✓| ✓| tenths of degrees (ex 325 = 32.5 degrees; 91 = 9.1 degrees)|
140 | 8|Position in **P**ulse| P| QP| | | ✓| microseconds|(((
141 See details below
142 )))
143 | 9|Position in **D**egrees| D| QD| | | ✓| tenths of degrees (ex 325 = 32.5 degrees; 91 = 9.1 degrees)|
144 | 10|**W**heel mode in **D**egrees| WD| QWD| | | ✓| tenths of degrees per second (ex 248 = 24.8 degrees per second)|
145 | 11|**W**heel mode in **R**PM| WR| QWR| | | ✓| rpm|
146 | 12|Max **S**peed in **D**egrees| SD| QSD| CSD| ✓| ✓| tenths of degrees per second (ex 248 = 24.8 degrees per second)|QSD: Add modifier "2" for instantaneous speed
147 | 13|Max **S**peed in **R**PM| SR| QSR| CSR| ✓| ✓| rpm|QSR: Add modifier "2" for instantaneous speed
148 | 14|**A**ngular **S**tiffness| AS| QAS| CAS| ✓| ✓|none|-4 to +4, but suggested values are between 0 to +4
149 | 15|**A**ngular **H**olding Stiffness|AH|QAH|CAH| | ✓|none|-10 to +10, with default as 0.
150 |15b|**A**ngular **A**cceleration|AA|QAA|CAA| | ✓|degrees per second squared|Increments of 10 degrees per second squared
151 |15c|**A**ngular **D**eceleration|AD|QAD|CAD| | ✓|degrees per second squared|Increments of 10 degrees per second squared
152 |15d|**M**otion **C**ontrol|MC|QMC| | | ✓|none|MC0 to disable motion control, MC1 to enable. Session specific
153 | 16|**LED** Color| LED| QLED| CLED| ✓| ✓| none (integer from 1 to 8)|0=OFF 1=RED 2=GREEN 3= BLUE 4=YELLOW 5=CYAN 6=MAGENTA, 7=WHITE
154 | 17|**ID** #| | QID| CID| | ✓| none (integer from 0 to 250)|Note: ID 254 is a "broadcast" which all servos respond to
155 | 18|**B**aud rate| B| QB| CB| | ✓| none (integer)|
156 | 19|**G**yre direction (**G**)| G| QG| CG| ✓| ✓| none | Gyre / rotation direction where 1= CW (clockwise) -1 = CCW (counter-clockwise)
157 | 20|**F**irst Position (**P**ulse)| | QFP|CFP | ✓| ✓| none |
158 | 21|**F**irst Position (**D**egrees)| | QFD|CFD| ✓| ✓| none |
159 | 22|**T**arget (**D**egree) **P**osition| | QDT| | | ✓| tenths of degrees (ex 325 = 32.5 degrees; 91 = 9.1 degrees)|
160 | 23|**M**odel| | QM| | | | none (integer)|
161 | 24|Serial **N**umber| | QN| | | | none (integer)|
162 | 25|**F**irmware version| | QF| | | | none (integer)|
163 | 26|**Q**uery (general status)| | Q| | | ✓| none (integer from 1 to 8)| See command description for details
164 | 27|**V**oltage| | QV| | | ✓| millivolts (ex 5936 = 5936mV = 5.936V)|
165 | 28|**T**emperature| | QT| | | ✓| tenths of degrees Celsius|Max temp before error: 85°C (servo goes limp)
166 | 29|**C**urrent| | QC| | | ✓| milliamps (ex 200 = 0.2A)|
167 | 30|**RC** Mode| | |CRC| |✓|none|(((
168 CRC: Add modifier "1" for RC-position mode.
169 CRC: Add modifier "2" for RC-wheel mode.
170 Any other value for the modifier results in staying in smart mode.
171 Puts the servo into RC mode. To revert to smart mode, use the button menu.
172 )))
173 |31|**RESET**| | | | | ✓|none|Soft reset. See command for details.
174 |32|**DEFAULT**| | | | |✓|none|Revert to firmware default values. See command for details
175 |33|**UPDATE**| | | | |✓|none|Update firmware. See command for details.
176
177 = Details =
178
179 __1. Limp (**L**)__
180
181 Example: #5L<cr>
182
183 This action causes the servo to go "limp". The microcontroller will still be powered, but the motor will not. As an emergency safety feature, should the robot not be doing what it is supposed to or risks damage, use the broadcast ID to set all servos limp #254L<cr>.
184
185 __2. Halt & Hold (**H**)__
186
187 Example: #5H<cr>
188
189 This action overrides whatever the servo might be doing at the time the command is received (accelerating, moving continuously etc.) and causes it to stop immediately and hold that position.
190
191 __3. Timed move (**T**)__
192
193 Example: #5P1500T2500<cr>
194
195 Timed move can be used only as a modifier for a position (P) action. The units are in milliseconds, so a timed move of 2500 milliseconds would cause the servo to rotate from its current position to the desired position in 2.5 seconds. This command is in place to ensure backwards compatibility with the SSC-32 / 32U protocol.
196
197 __4. Speed (**S**)__
198
199 Example: #5P1500S750<cr>
200
201 This command is a modifier only for a position (P) action and determines the speed of the move in microseconds per second. A speed of 750 microseconds would cause the servo to rotate from its current position to the desired position at a speed of 750 microseconds per second. This command is in place to ensure backwards compatibility with the SSC-32 / 32U protocol.
202
203 __5. (Relative) Move in Degrees (**MD**)__
204
205 Example: #5MD123<cr>
206
207 The relative move command causes the servo to read its current position and move the specified number of tenths of degrees in the corresponding position. For example if the servo is set to rotate CW (default) and an MD command of 123 is sent to the servo, it will cause the servo to rotate clockwise by 12.3 degrees. Negative commands would cause the servo to rotate in the opposite configured direction.
208
209 __6. Origin Offset Action (**O**)__
210
211 Example: #5O2400<cr>
212
213 This command allows you to temporarily change the origin of the servo in relation to the factory zero position. The setting will be lost upon servo reset / power cycle. Origin offset commands are not cumulative and always relate to factory zero. Note that for a given session, the O command overrides the CO command. In the first image, the origin at factory offset '0' (centered).
214
215 [[image:LSS-servo-default.jpg]]
216
217 In the second image, the origina, as well as the angular range (explained below) have been shifted by 240.0 degrees:
218
219 [[image:LSS-servo-origin.jpg]]
220
221 Origin Offset Query (**QO**)
222
223 Example: #5QO<cr> Returns: *5QO-13
224
225 This allows you to query the angle (in tenths of degrees) of the origin in relation to the factory zero position.
226
227 Configure Origin Offset (**CO**)
228
229 Example: #5CO-24<cr>
230
231 This command allows you to change the origin of the servo in relation to the factory zero position in EEPROM. The setting will be saved upon servo reset / power cycle. Origin offset configuration commands are not cumulative and always relate to factory zero. The new origin is also used in RC mode.
232
233 __7. Angular Range (**AR**)__
234
235 Example: #5AR1800<cr>
236
237 This command allows you to temporarily change the total angular range of the servo in tenths of degrees. This applies to the Position in Pulse (P) command and RC mode. The default for (P) and RC mode is 1800 (180.0 degrees total, or ±90.0 degrees). In the first image,
238
239 [[image:LSS-servo-default.jpg]]
240
241 Here, the angular range has been restricted to 180.0 degrees, or -90.0 to +90.0. The center has remained unchanged.
242
243 [[image:LSS-servo-ar.jpg]]
244
245 The angular range action command (ex. #5AR1800<cr>) and origin offset action command (ex. #5O-1200<cr>) an be used to move both the center and limit the angular range:
246
247 [[image:LSS-servo-ar-o-1.jpg]]
248
249 Query Angular Range (**QAR**)
250
251 Example: #5QAR<cr> might return *5AR2756
252
253 Configure Angular Range (**CAR**)
254
255 This command allows you to change the total angular range of the servo in tenths of degrees in EEPROM. The setting will be saved upon servo reset / power cycle.
256
257 __8. Position in Pulse (**P**)__
258
259 Example: #5P2334<cr>
260
261 The position in PWM pulses was retained in order to be backward compatible with the SSC-32 / 32U protocol. This relates the desired angle with an RC standard PWM pulse and is further explained in the SSC-32 and SSC-32U manuals found on Lynxmotion.com. Without any modifications to configuration considered, and a ±90.0 degrees standard range where 1500 microseconds is centered, a pulse of 2334 would set the servo to 165.1 degrees. Valid values for P are [500, 2500]. Values outside this range are corrected to end points.
262
263 Query Position in Pulse (**QP**)
264
265 Example: #5QP<cr> might return *5QP2334
266
267 This command queries the current angular position in PWM "units". The user must take into consideration that the response includes any angular range and origin configurations in order to determine the actual angle. 
268 Valid values for QP are {-500, [500, 2500], -2500}. Values outside the [500, 2500] range are given a negative corresponding end point value to indicate they are out of bounds (note that if the servo is physically located at one of the endpoints, it may return a negative number if it is a fraction of a degree beyond the position).
269
270 __9. Position in Degrees (**D**)__
271
272 Example: #5PD1456<cr>
273
274 This moves the servo to an angle of 145.6 degrees, where the center (0) position is centered. Negative values (ex. -176 representing -17.6 degrees) are used. A full circle would be from -1800 to 1800 degrees. A value of 2700 would be the same angle as -900, except the servo would move in a different direction.
275
276 Larger values are permitted and allow for multi-turn functionality using the concept of virtual position.
277
278 Query Position in Degrees (**QD**)
279
280 Example: #5QD<cr> might return *5QD132<cr>
281
282 This means the servo is located at 13.2 degrees.
283
284 __10. Wheel Mode in Degrees (**WD**)__
285
286 Ex: #5WD900<cr>
287
288 This command sets the servo to wheel mode where it will rotate in the desired direction at the selected speed. The example above would have the servo rotate at 90.0 degrees per second clockwise (assuming factory default configurations).
289
290 Query Wheel Mode in Degrees (**QWD**)
291
292 Ex: #5QWD<cr> might return *5QWD900<cr>
293
294 The servo replies with the angular speed in tenths of degrees per second. A negative sign would indicate the opposite direction (for factory default a negative value would be counter clockwise).
295
296 __11. Wheel Mode in RPM (**WR**)__
297
298 Ex: #5WR40<cr>
299
300 This command sets the servo to wheel mode where it will rotate in the desired direction at the selected rpm. Wheel mode (a.k.a. "continuous rotation") has the servo operate like a geared DC motor. The servo's maximum rpm cannot be set higher than its physical limit at a given voltage. The example above would have the servo rotate at 40 rpm clockwise (assuming factory default configurations).
301
302 Query Wheel Mode in RPM (**QWR**)
303
304 Ex: #5QWR<cr> might return *5QWR40<cr>
305
306 The servo replies with the angular speed in rpm. A negative sign would indicate the opposite direction (for factory default a negative value would be counter clockwise).
307
308 __12. Speed in Degrees (**SD**)__
309
310 Ex: #5SD1800<cr>
311
312 This command sets the servo's maximum speed for action commands in tenths of degrees per second for that session. In the example above, the servo's maximum speed for that session would be set to 180.0 degrees per second. Therefore maximum speed for actions can be set "on the fly". The servo's maximum speed cannot be set higher than its physical limit at a given voltage. SD overrides CSD (described below) for that session. Upon reset or power cycle, the servo reverts to the value associated with CSD as described below. Note that SD and SR (described below) are effectively the same, but allow the user to specify the speed in either unit. The last command (either SR or SD) is what the servo uses for that session.
313
314 Query Speed in Degrees (**QSD**)
315
316 Ex: #5QSD<cr> might return *5QSD1800<cr>
317
318 By default QSD will return the current session value, which is set to the value of CSD as reset/power cycle and changed whenever a SD/SR command is processed.
319 If #5QSD1<cr> is sent, the configured maximum speed (CSD value) will be returned instead. You can also query the current speed using "2" and the current target travel speed using "3". See the table below for an example:
320
321 |**Command sent**|**Returned value (1/10 °)**
322 |ex: #5QSD<cr>|Session value for maximum speed (set by latest SD/SR command)
323 |ex: #5QSD1<cr>|Configured maximum speed  (set by CSD/CSR)
324 |ex: #5QSD2<cr>|Instantaneous speed (same as QWD)
325 |ex: #5QSD3<cr>|Target travel speed
326
327 Configure Speed in Degrees (**CSD**)
328
329 Ex: #5CSD1800<cr>
330
331 Using the CSD command sets the servo's maximum speed which is saved in EEPROM. In the example above, the servo's maximum speed will be set to 180.0 degrees per second. When the servo is powered on (or after a reset), the CSD value is used. Note that CSD and CSR (described below) are effectively the same, but allow the user to specify the speed in either unit. The last command (either CSR or CSD) is what the servo uses for that session.
332
333 __13. Speed in RPM (**SR**)__
334
335 Ex: #5SD45<cr>
336
337 This command sets the servo's maximum speed for action commands in rpm for that session. In the example above, the servo's maximum speed for that session would be set to 45rpm. Therefore maximum speed for actions can be set "on the fly". The servo's maximum speed cannot be set higher than its physical limit at a given voltage. SD overrides CSD (described below) for that session. Upon reset or power cycle, the servo reverts to the value associated with CSD as described below. Note that SD (described above) and SR are effectively the same, but allow the user to specify the speed in either unit. The last command (either SR or SD) is what the servo uses for that session.
338
339 Query Speed in Degrees (**QSR**)
340
341 Ex: #5QSR<cr> might return *5QSR45<cr>
342
343 By default QSR will return the current session value, which is set to the value of CSR as reset/power cycle and changed whenever a SD/SR command is processed.
344 If #5QSR1<cr> is sent, the configured maximum speed (CSR value) will be returned instead. You can also query the current speed using "2" and the current target travel speed using "3". See the table below for an example:
345
346 |**Command sent**|**Returned value (1/10 °)**
347 |ex: #5QSR<cr>|Session value for maximum speed (set by latest SD/SR command)
348 |ex: #5QSR1<cr>|Configured maximum speed  (set by CSD/CSR)
349 |ex: #5QSR2<cr>|Instantaneous speed (same as QWR)
350 |ex: #5QSR3<cr>|Target travel speed
351
352 Configure Speed in RPM (**CSR**)
353
354 Ex: #5CSR45<cr>
355
356 Using the CSR command sets the servo's maximum speed which is saved in EEPROM. In the example above, the servo's maximum speed will be set to 45rpm. When the servo is powered on (or after a reset), the CSR value is used. Note that CSD and CSR are effectively the same, but allow the user to specify the speed in either unit. The last command (either CSR or CSD) is what the servo uses for that session.
357
358 __14. Angular Stiffness (**AS**)__
359
360 The servo's rigidity / angular stiffness can be thought of as (though not identical to) a damped spring in which the value affects the stiffness and embodies how much, and how quickly the servo tried keep the requested position against changes.
361
362 A positive value of "angular stiffness":
363
364 * The more torque will be applied to try to keep the desired position against external input / changes
365 * The faster the motor will reach its intended travel speed and the motor will decelerate faster and nearer to its target position
366
367 A negative value on the other hand:
368
369 * Causes a slower acceleration to the travel speed, and a slower deceleration
370 * Allows the target position to deviate more from its position before additional torque is applied to bring it back
371
372 The default value is zero and the effect becomes extreme by -4, +4. There are no units, only integers between -4 to 4. Greater values produce increasingly erratic behavior.
373
374 Ex: #5AS-2<cr>
375
376 This reduces the angular stiffness to -2 for that session, allowing the servo to deviate more around the desired position. This can be beneficial in many situations such as impacts (legged robots) where more of a "spring" effect is desired. Upon reset, the servo will use the value stored in memory, based on the last configuration command.
377
378 Ex: #5QAS<cr>
379
380 Queries the value being used.
381
382 Ex: #5CAS<cr>
383
384 Writes the desired angular stiffness value to memory.
385
386 __15. Angular Hold Stiffness (**AH**)__
387
388 The angular holding stiffness determines the servo's ability to hold a desired position under load. Values can be from -10 to 10, with the default being 0. Note that negative values mean the final position can be easily deflected.
389
390 Ex: #5AH3<cr>
391
392 This sets the holding stiffness for servo #5 to 3 for that session.
393
394 Query Angular Hold Stiffness (**QAH**)
395
396 Ex: #5QAH<cr> might return *5QAH3<cr>
397
398 This returns the servo's angular holding stiffness value.
399
400 Configure Angular Hold Stiffness (**CAH**)
401
402 Ex: #5CAH2<cr>
403
404 This writes the angular holding stiffness of servo #5 to 2 to EEPROM
405
406 __15b: Angular Acceleration (**AA**)__
407
408 {More details to come}
409
410 __15c: Angular Deceleration (**AD**)__
411
412 {More details to come}
413
414 __15d: Motion Control (**MC**)__
415
416 {More details to come}
417
418 __16. RGB LED (**LED**)__
419
420 Ex: #5LED3<cr>
421
422 This action sets the servo's RGB LED color for that session.The LED can be used for aesthetics, or (based on user code) to provide visual status updates. Using timing can create patterns.
423
424 0=OFF 1=RED 2=GREEN 3= BLUE 4=YELLOW 5=CYAN 6= 7=MAGENTA, 8=WHITE 
425
426 Query LED Color (**QLED**)
427
428 Ex: #5QLED<cr> might return *5QLED5<cr>
429
430 This simple query returns the indicated servo's LED color.
431
432 Configure LED Color (**CLED**)
433
434 Configuring the LED color via the CLED command sets the startup color of the servo after a reset or power cycle. Note that it also changes the session's LED color immediately as well.
435
436 __17. Identification Number__
437
438 A servo's identification number cannot be set "on the fly" and must be configured via the CID command described below. The factory default ID number for all servos is 0. Since smart servos are intended to be daisy chained, in order to respond differently from one another, the user must set different identification numbers. Servos with the same ID and baud rate will all receive and react to the same commands.
439
440 Query Identification (**QID**)
441
442 EX: #254QID<cr> might return *QID5<cr>
443
444 When using the query ID command, it is best to only have one servo connected and thus receive only one reply using the broadcast command (ID 254). Alternatively, pushing the button upon startup and temporarily setting the servo ID to 255 will still result in the servo responding with its "real" ID.
445
446 Configure ID (**CID**)
447
448 Ex: #4CID5<cr>
449
450 Setting a servo's ID in EEPROM is done via the CID command. All servos connected to the same serial bus will be assigned that ID. In most situations each servo must be set a unique ID, which means each servo must be connected individually to the serial bus and receive a unique CID number. It is best to do this before the servos are added to an assembly. Numbered stickers are provided to distinguish each servo after their ID is set, though you are free to use whatever alternative method you like.
451
452 __18. Baud Rate__
453
454 A servo's baud rate cannot be set "on the fly" and must be configured via the CB command described below. The factory default baud rate for all servos is 9600. Since smart servos are intended to be daisy chained, in order to respond to the same serial bus, all servos in that project should ideally be set to the same baud rate. Setting different baud rates will have the servos respond differently and may create issues. Available baud rates are: 9.6 kbps, 19.2 kbps, 38.4 kbps, 57.6 kbps, 115.2 kbps, 230.4 kbps, 250.0 kbps, 460.8 kbps, 500.0 kbps, 750.0 kbps*, 921.6 kbps*. Servos are shipped with a baud rate set to 9600. The baud rates are currently restricted to those above.
455 \*: Current tests reveal baud rates above 500 kbps are unstable and can cause timeouts. Please keep this in mind if using those / testing them out.
456
457 Query Baud Rate (**QB**)
458
459 Ex: #5QB<cr> might return *5QB9600<cr>
460
461 Querying the baud rate is used simply to confirm the CB configuration command before the servo is power cycled.
462
463 Configure Baud Rate (**CB**)
464
465 Ex: #5CB9600<cr>
466
467 Sending this command will change the baud rate associated with servo ID 5 to 9600 bits per second.
468
469 __19. Gyre Rotation Direction__
470
471 "Gyre" is defined as a circular course or motion. The effect of changing the gyre direction is as if you were to use a mirror image of a circle. CW = 1; CCW = -1. The factory default is clockwise (CW).
472
473 {images showing before and after with AR and Origin offset}
474
475 Query Gyre Direction (**QG**)
476
477 Ex: #5QG<cr> might return *5QG-1<cr>
478
479 The value returned above means the servo is in a counter-clockwise gyration.
480
481 Configure Gyre (**CG**)
482
483 Ex: #5CG-1<cr>
484
485 This changes the gyre direction as described above and also writes to EEPROM.
486
487 __20. First / Initial Position (pulse)__
488
489 In certain cases, a user might want to have the servo move to a specific angle upon power up. We refer to this as "first position". The factory default has no first position value stored in EEPROM and therefore upon power up, the servo remains limp until a position (or hold command) is assigned. FP and FD are different in that FP is used for RC mode only, whereas FD is used for smart mode only.
490
491 Query First Position in Pulses (**QFP**)
492
493 Ex: #5QFP<cr> might return *5QFP1550<cr>
494
495 The reply above indicates that servo with ID 5 has a first position pulse of 1550 microseconds. If no first position has been set, servo will respond with DIS ("disabled").
496
497 Configure First Position in Pulses (**CFP**)
498
499 Ex: #5CP1550<cr>
500
501 This configuration command means the servo, when set to RC mode, will immediately move to an angle equivalent to having received an RC pulse of 1550 microseconds upon power up. Sending a CFP command without a number results in the servo remaining limp upon power up (i.e. disabled).
502
503 __21. First / Initial Position (Degrees)__
504
505 In certain cases, a user might want to have the servo move to a specific angle upon power up. We refer to this as "first position". The factory default has no first position value stored in EEPROM and therefore upon power up, the servo remains limp until a position (or hold command) is assigned. FP and FD are different in that FP is used for RC mode only, whereas FD is used for smart mode only.
506
507 Query First Position in Degrees (**QFD**)
508
509 Ex: #5QFD<cr> might return *5QFD64<cr>
510
511 The reply above indicates that servo with ID 5 has a first position pulse of 1550 microseconds.
512
513 Configure First Position in Degrees (**CFD**)
514
515 Ex: #5CD64<cr>
516
517 This configuration command means the servo, when set to smart mode, will immediately move to 6.4 degrees upon power up. Sending a CFD command without a number results in the servo remaining limp upon power up.
518
519 __22. Query Target Position in Degrees (**QDT**)__
520
521 Ex: #5QDT<cr> might return *5QDT6783<cr>
522
523 The query target position command returns the target angle during and after an action which results in a rotation of the servo horn. In the example above, the servo is rotating to a virtual position of 678.3 degrees. Should the servo not have a target position or be in wheel mode, it will respond without a number (Ex: *5QDT<cr>).
524
525 __23. Query Model (**QM**)__
526
527 Ex: #5QM<cr> might return *5QM11<cr>
528
529 This reply means the servo model is 1.1, meaning high speed servo, first revision. 1=HS (high speed) 2=ST (standard) 3=HT (high torque)
530
531 __24. Query Serial Number (**QN**)__
532
533 Ex: #5QN<cr> might return *5QN~_~_<cr>
534
535 The number in the response is the servo's serial number which is set and cannot be changed.
536
537 __25. Query Firmware (**QF**)__
538
539 Ex: #5QF<cr> might return *5QF11<cr>
540
541 The integer in the reply represents the firmware version with one decimal, in this example being 1.1
542
543 __26. Query Status (**Q**)__
544
545 Ex: #5Q<cr> might return *5Q6<cr>, which indicates the motor is holding a position.
546
547 |*Value returned|**Status**|**Detailed description**
548 |ex: *5Q0<cr>|Unknown|LSS is unsure
549 |ex: *5Q1<cr>|Limp|Motor driving circuit is not powered and horn can be moved freely
550 |ex: *5Q2<cr>|Free moving|Motor driving circuit is not powered and horn can be moved freely
551 |ex: *5Q3<cr>|Accelerating|Increasing speed from rest (or previous speeD) towards travel speed
552 |ex: *5Q4<cr>|Traveling|Moving at a stable speed
553 |ex: *5Q5<cr>|Deccelerating|Decreasing speed towards travel speed towards rest
554 |ex: *5Q6<cr>|Holding|Keeping current position
555 |ex: *5Q7<cr>|Stepping|Special low speed mode to maintain torque
556 |ex: *5Q8<cr>|Outside limits|More details coming soon
557 |ex: *5Q9<cr>|Stuck|Motor cannot perform request movement at current speed setting
558 |ex: *5Q10<cr>|Blocked|Similar to stuck, but the motor is at maxiumum duty and still cannot move (i.e.: stalled)
559
560 __27. Query Voltage (**QV**)__
561
562 Ex: #5QV<cr> might return *5QV11200<cr>
563
564 The number returned has one decimal, so in the case above, servo with ID 5 has an input voltage of 11.2V (perhaps a three cell LiPo battery).
565
566 __28. Query Temperature (**QT**)__
567
568 Ex: #5QT<cr> might return *5QT564<cr>
569
570 The units are in tenths of degrees Celcius, so in the example above, the servo's internal temperature is 56.4 degrees C. To convert from degrees Celcius to degrees Farenheit, multiply by 1.8 and add 32. Therefore 56.4C = 133.52F.
571
572 __29. Query Current (**QC**)__
573
574 Ex: #5QC<cr> might return *5QC140<cr>
575
576 The units are in milliamps, so in the example above, the servo is consuming 140mA, or 0.14A.
577
578 __30. RC Mode (**CRC**)__
579
580 This command puts the servo into RC mode (position or continuous), where it will only respond to RC pulses. Note that because this is the case, the servo will no longer accept serial commands. The servo can be placed back into smart mode by using the button menu.
581
582 |**Command sent**|**Note**
583 |ex: #5CRC<cr>|Stay in smart mode.
584 |ex: #5CRC1<cr>|Change to RC position mode.
585 |ex: #5CRC2<cr>|Change to RC continuous (wheel) mode.
586 |ex: #5CRC*<cr>|Where * is any number or value. Stay in smart mode.
587
588 EX: #5CRC<cr>
589
590 __31. RESET__
591
592 Ex: #5RESET<cr> or #5RS<cr>
593
594 This command does a "soft reset" (no power cycle required) and reverts all commands to those stored in EEPROM (i.e. configuration commands).
595
596 __32. DEFAULT & CONFIRM__
597
598 Ex: #5DEFAULT<cr>
599
600 This command sets in motion the reset all values to the default values included with the version of the firmware installed on that servo. The servo then waits for the CONFIRM command. Any other command received will cause the servo to exit the DEFAULT function.
601
602 EX: #5DEFAULT<cr> followed by #5CONFIRM<cr>
603
604 Since it it not common to have to restore all configurations, a confirmation command is needed after a firmware command is sent. Should any command other than CONFIRM be received by the servo after the firmware command has been received, it will leave the firmware action.
605
606 Note that after the CONFIRM command is sent, the servo will automatically perform a RESET.
607
608 __33. UPDATE & CONFIRM__
609
610 Ex: #5UPDATE<cr>
611
612 This command sets in motion the equivalent of a long button press when the servo is not powered in order to enter firmware update mode. This is useful should the button be broken or inaccessible. The servo then waits for the CONFIRM command. Any other command received will cause the servo to exit the UPDATE function.
613
614 EX: #5UPDATE<cr> followed by #5CONFIRM<cr>
615
616 Since it it not common to have to update firmware, a confirmation command is needed after an UPDATE command is sent. Should any command other than CONFIRM be received by the servo after the firmware command has been received, it will leave the firmware action.
617
618 Note that after the CONFIRM command is sent, the servo will automatically perform a RESET.
619