Wiki source code of LSS - Communication Protocol

Version 78.1 by Eric Nantel on 2019/01/18 13:22

Show last authors
1 = Table of Contents =
2
3 {{toc depth="3"/}}
4
5 = Protocol Concepts =
6
7 The Lynxmotion Smart Servo (LSS) protocol was created in order to be as simple and straightforward as possible from a user perspective, while at the same time trying to stay compact and robust yet highly versatile. Almost everything one might expect to be able to configure for a smart servo motor is available.
8
9 == Session ==
10
11 A "session" is defined as the time between when the servo is powered ON to when it is powered OFF or reset.
12
13 == Action Commands ==
14
15 Action commands are sent serially to the servo's Rx pin and must be set in the following format:
16
17 1. Start with a number sign # (U+0023)
18 1. Servo ID number as an integer
19 1. Action command (one to three letters, no spaces, capital or lower case)
20 1. Action value in the correct units with no decimal
21 1. End with a control / carriage return '<cr>'
22
23 (((
24 Ex: #5PD1443<cr>
25
26 Move servo with ID #5 to a position of 144.3 degrees.
27
28 Action commands cannot be combined with query commands, and only one action command can be sent at a time.
29
30 Action commands are session-specific, therefore once a servo is power cycled, it will not have any "memory" of previous actions or virtual positions (as described at the bottom of this page).
31
32 == Action Modifiers ==
33
34 Two commands can be used as action modifiers only: Timed Move and Speed. The format is:
35
36 1. Start with a number sign # (U+0023)
37 1. Servo ID number as an integer
38 1. Action command (one to three letters, no spaces, capital or lower case)
39 1. Action value in the correct units with no decimal
40 1. Modifier command (one letter)
41 1. Modifier value in the correct units with no decimal
42 1. End with a control / carriage return '<cr>'
43
44 Ex: #5P1456T1263<cr>
45
46 Results in the servo rotating from the current angular position to a pulse position of 1456 in 1263 milliseconds.
47
48 Action modifiers can only be used with certain commands.
49 )))
50
51 == Configuration Commands ==
52
53 Configuration commands affect the servo's current session* but unlike action commands, configuration commands are written to EEPROM and are retained even if the servo loses power (therefore NOT session specific). Not all action commands have a corresponding configuration and vice versa. Certain configurations are retained for when the servo is used in RC model. More information can be found on the [[LSS - RC PWM page>>doc:Lynxmotion Smart Servo (LSS).LSS - RC PWM.WebHome]].
54
55 1. Start with a number sign # (U+0023)
56 1. Servo ID number as an integer
57 1. Configuration command (two to three letters, no spaces, capital or lower case)
58 1. Configuration value in the correct units with no decimal
59 1. End with a control / carriage return '<cr>'
60
61 Ex: #5CO-50<cr>
62
63 Assigns an absolute origin offset of -5.0 degrees (with respect to factory origin) to servo #5 and changes the offset for that session to -5.0 degrees.
64
65 Configuration commands are not cumulative, in that if two configurations are sent at any time, only the last configuration is used and stored.
66
67 *Important Note: the one exception is the baud rate - the servo's current session retains the given baud rate. The new baud rate will only be in place when the servo is power cycled.
68
69 == Query Commands ==
70
71 Query commands are sent serially to the servo's Rx pin and must be set in the following format:
72
73 1. Start with a number sign # (U+0023)
74 1. Servo ID number as an integer
75 1. Query command (one to three letters, no spaces, capital or lower case)
76 1. End with a control / carriage return '<cr>'
77
78 (((
79 Ex: #5QD<cr>Query position in degrees for servo #5
80 )))
81
82 (((
83 The query will return a value via the Tx pin with the following format:
84
85 1. Start with an asterisk (U+002A)
86 1. Servo ID number as an integer
87 1. Query command (one to three letters, no spaces, capital letters)
88 1. The reported value in the units described, no decimals.
89 1. End with a control / carriage return '<cr>'
90
91 (((
92 Ex: *5QD1443<cr>
93 )))
94
95 Indicates that servo #5 is currently at 144.3 degrees.
96
97 **Session vs Configuration Query**
98
99 By default, the query command returns the sessions' value; should no action commands have been sent to change, it will return the value saved in EEPROM from the last configuration command.
100
101 In order to query the value in EEPROM, add a '1' to the query command.
102
103 Ex: #5CSR20<cr> sets the maximum speed for servo #5 to 20rpm upon RESET (explained below).
104
105 After RESET: #5SR4<cr> sets the session's speed to 4rpm.
106
107 #5QSR<cr> would return *5QSR4<cr> which represents the value for that session.
108
109 #5QSR1<cr> would return *5QSR20<cr> which represents the value in EEPROM
110
111 == Virtual Angular Position ==
112
113 {In progress}
114
115 A "virtual position" is one which allows for multiple rotations of the output horn, moving the center position and more. The "absolute position" would be the angle of the output shaft with respect to 360.0 degrees.
116
117 [[image:LSS-servo-positions.jpg]]
118
119 Example: Gyre direction / rotation is positive (clockwise), and origin offset has not been modified. Each square represents 30 degrees.
120
121 #1D-300<cr> The servo is sent a command to move to -30.0 degrees (green arrow)
122
123 #1D2100<cr> This second position command is sent to the servo, which moves it to 210.0 degrees (orange arrow)
124
125 #1D-4200<cr> This next command rotates the servo counterclockwise to a position of -420 degrees (red arrow), which means one full rotation of 360 degrees,  stopping at an absolute position of 60.0 degrees (420.0-360.0), with a virtual position of -420.0 degrees.
126
127 Although the final physical position would be the same as if the servo were commanded to move to -60.0 degrees, the servo is in fact at -420.0 degrees.
128
129 #1D4800<cr> This new command is sent which would then cause the servo to rotate from -420.0 degrees to 480.0 degrees (blue arrow), which would be a total of 900 degrees of clockwise rotation, or 2.5 complete rotations.
130
131 #1D3300<cr> would cause the servo to rotate from 480.0 degrees to 330.0 degrees (yellow arrow).
132
133 If / once the servo loses power or is power cycled, it also loses the virtual position associated with that session. For example, if the virtual position was 480.0 degrees before power is cycled, upon power up the servo's position will be read as +120.0 degrees from zero (assuming center position has not been modified).
134 )))
135
136 = Command List =
137
138 |= #|=Description|= Action|= Query|= Config|= RC|= Serial|= Units|= Notes
139 | 1|[[**L**imp>>||anchor="H1.Limp28L29"]]| L| | | | ✓|none|
140 | 2|[[**H**alt & Hold>>||anchor="H2.Halt26Hold28H29"]]| H| | | | ✓|none|
141 | 3|[[**T**imed move>>||anchor="H3.Timedmove28T29"]]| T| | | | ✓|milliseconds| Modifier only (P, D, MD)
142 | 4|[[**S**peed>>||anchor="H4.Speed28S29"]]| S| | | | ✓|microseconds / second| Modifier only (P)
143 | 5|[[**M**ove in **D**egrees (relative)>>||anchor="H5.28Relative29MoveinDegrees28MD29"]]| MD| | | | ✓|tenths of degrees (ex 325 = 32.5 degrees; 91 = 9.1 degrees)|
144 | 6|[[**O**rigin Offset>>||anchor="H6.OriginOffsetAction28O29"]]| O| QO| CO| ✓| ✓|tenths of degrees (ex 325 = 32.5 degrees; 91 = 9.1 degrees)|
145 | 7|[[**A**ngular **R**ange>>||anchor="H7.AngularRange28AR29"]]| AR| QAR| CAR| ✓| ✓|tenths of degrees (ex 325 = 32.5 degrees; 91 = 9.1 degrees)|
146 | 8|[[Position in **P**ulse>>||anchor="H8.PositioninPulse28P29"]]| P| QP| | | ✓|microseconds|(((
147 See details below
148 )))
149 | 9|[[Position in **D**egrees>>||anchor="H9.PositioninDegrees28D29"]]| D| QD| | | ✓|tenths of degrees (ex 325 = 32.5 degrees; 91 = 9.1 degrees)|
150 | 10|[[**W**heel mode in **D**egrees>>||anchor="H10.WheelModeinDegrees28WD29"]]| WD| QWD| | | ✓|tenths of degrees per second (ex 248 = 24.8 degrees per second)|A.K.A. "Speed mode" or "Continuous rotation"
151 | 11|[[**W**heel mode in **R**PM>>||anchor="H11.WheelModeinRPM28WR29"]]| WR| QWR| | | ✓| rpm|A.K.A. "Speed mode" or "Continuous rotation"
152 | 12|[[Max **S**peed in **D**egrees>>||anchor="H12.SpeedinDegrees28SD29"]]| SD| QSD| CSD| ✓| ✓|tenths of degrees per second (ex 248 = 24.8 degrees per second)|QSD: Add modifier "2" for instantaneous speed
153 | 13|[[Max **S**peed in **R**PM>>||anchor="H13.SpeedinRPM28SR29"]]| SR| QSR| CSR| ✓| ✓|rpm|QSR: Add modifier "2" for instantaneous speed
154 | 14|[[**A**ngular **S**tiffness>>||anchor="H14.AngularStiffness28AS29"]]| AS| QAS| CAS| ✓| ✓|none|-4 to +4, but suggested values are between 0 to +4
155 | 15|[[**A**ngular **H**olding Stiffness>>||anchor="H15.AngularHoldStiffness28AH29"]]|AH|QAH|CAH| | ✓|none|-10 to +10, with default as 0.
156 |15b|[[**A**ngular **A**cceleration>>||anchor="H15b:AngularAcceleration28AA29"]]|AA|QAA|CAA| | ✓|degrees per second squared|Increments of 10 degrees per second squared
157 |15c|[[**A**ngular **D**eceleration>>||anchor="H15c:AngularDeceleration28AD29"]]|AD|QAD|CAD| | ✓|degrees per second squared|Increments of 10 degrees per second squared
158 |15d|[[**E**nable **M**otion control>>||anchor="H15d:MotionControl28MC29"]]|EM|QEM| | | ✓|none|EM0 to disable motion control, EM1 to enable. Session specific / does not survive power cycles
159 | 16|[[**LED** Color>>||anchor="H16.RGBLED28LED29"]]| LED| QLED| CLED| ✓| ✓|none (integer from 1 to 8)|0=OFF 1=RED 2=GREEN 3= BLUE 4=YELLOW 5=CYAN 6=MAGENTA, 7=WHITE
160 | 17|[[**ID** #>>||anchor="H17.IdentificationNumber"]]| | QID| CID| | ✓|none (integer from 0 to 250)|Note: ID 254 is a "broadcast" which all servos respond to
161 | 18|[[**B**aud rate>>||anchor="H18.BaudRate"]]| B| QB| CB| | ✓|none (integer)|
162 | 19|[[**G**yre direction (**G**)>>||anchor="H19.GyreRotationDirection"]]| G| QG| CG| ✓| ✓|none | Gyre / rotation direction where 1= CW (clockwise) -1 = CCW (counter-clockwise)
163 | 20|[[**F**irst Position (**P**ulse)>>||anchor="H20.First2InitialPosition28pulse29"]]| | QFP|CFP | ✓| ✓|none |
164 | 21|[[**F**irst Position (**D**egrees)>>||anchor="H21.First2InitialPosition28Degrees29"]]| | QFD|CFD| ✓| ✓|none |
165 | 22|[[**T**arget (**D**egree) **P**osition>>||anchor="H22.QueryTargetPositioninDegrees28QDT29"]]| | QDT| | | ✓|tenths of degrees (ex 325 = 32.5 degrees; 91 = 9.1 degrees)|
166 | 23|[[**M**odel **S**tring>>||anchor="H23.QueryModelString28QMS29"]]| | QMS| | | |none (string)| Recommended to determine the model|
167 | 23b|[[**M**odel>>||anchor="H23b.QueryModel28QM29"]]| | QM| | | |none (integer)| Returns a raw value representing the three model inputs (36 bit)|
168 | 24|[[Serial **N**umber>>||anchor="H24.QuerySerialNumber28QN29"]]| | QN| | | |none (integer)|
169 | 25|[[**F**irmware version>>||anchor="H25.QueryFirmware28QF29"]]| | QF| | | |none (integer)|
170 | 26|[[**Q**uery (general status)>>||anchor="H26.QueryStatus28Q29"]]| | Q| | | ✓|none (integer from 1 to 8)| See command description for details
171 | 27|[[**V**oltage>>||anchor="H27.QueryVoltage28QV29"]]| | QV| | | ✓|millivolts (ex 5936 = 5936mV = 5.936V)|
172 | 28|[[**T**emperature>>||anchor="H28.QueryTemperature28QT29"]]| | QT| | | ✓|tenths of degrees Celsius|Max temp before error: 85°C (servo goes limp)
173 | 29|[[**C**urrent>>||anchor="H29.QueryCurrent28QC29"]]| | QC| | | ✓|milliamps (ex 200 = 0.2A)|
174 | 30|[[**RC** Mode>>||anchor="H30.RCMode28CRC29"]]| | |CRC| |✓|none|(((
175 CRC: Add modifier "1" for RC-position mode.
176 CRC: Add modifier "2" for RC-wheel mode.
177 Any other value for the modifier results in staying in smart mode.
178 Puts the servo into RC mode. To revert to smart mode, use the button menu.
179 )))
180 |31|[[**RESET**>>||anchor="H31.RESET"]]| | | | | ✓|none|Soft reset. See command for details.
181 |32|[[**DEFAULT**>>||anchor="H32.DEFAULTA026CONFIRM"]]| | | | |✓|none|Revert to firmware default values. See command for details
182 |33|[[**UPDATE**>>||anchor="H33.UPDATEA026CONFIRM"]]| | | | |✓|none|Update firmware. See command for details.
183
184 == Details ==
185
186 ====== __1. Limp (**L**)__ ======
187
188 Example: #5L<cr>
189
190 This action causes the servo to go "limp". The microcontroller will still be powered, but the motor will not. As an emergency safety feature, should the robot not be doing what it is supposed to or risks damage, use the broadcast ID to set all servos limp #254L<cr>.
191
192 ====== __2. Halt & Hold (**H**)__ ======
193
194 Example: #5H<cr>
195
196 This action overrides whatever the servo might be doing at the time the command is received (accelerating, moving continuously etc.) and causes it to stop immediately and hold that position.
197
198 ====== __3. Timed move (**T**)__ ======
199
200 Example: #5P1500T2500<cr>
201
202 Timed move can be used only as a modifier for a position (P) action. The units are in milliseconds, so a timed move of 2500 milliseconds would cause the servo to rotate from its current position to the desired position in 2.5 seconds. This command is in place to ensure backwards compatibility with the SSC-32 / 32U protocol.
203
204 Note: If the calculated speed at which a servo must rotate for a timed move is greater than its maximum speed (which depends on voltage and load), then it will move at its maximum speed, and the time of the move may be longer than requested.
205
206 ====== __4. Speed (**S**)__ ======
207
208 Example: #5P1500S750<cr>
209
210 This command is a modifier only for a position (P) action and determines the speed of the move in microseconds per second. A speed of 750 microseconds would cause the servo to rotate from its current position to the desired position at a speed of 750 microseconds per second. This command is in place to ensure backwards compatibility with the SSC-32 / 32U protocol.
211
212 ====== __5. (Relative) Move in Degrees (**MD**)__ ======
213
214 Example: #5MD123<cr>
215
216 The relative move command causes the servo to read its current position and move the specified number of tenths of degrees in the corresponding position. For example if the servo is set to rotate CW (default) and an MD command of 123 is sent to the servo, it will cause the servo to rotate clockwise by 12.3 degrees. Negative commands would cause the servo to rotate in the opposite configured direction.
217
218 ====== __6. Origin Offset Action (**O**)__ ======
219
220 Example: #5O2400<cr>
221
222 This command allows you to temporarily change the origin of the servo in relation to the factory zero position. The setting will be lost upon servo reset / power cycle. Origin offset commands are not cumulative and always relate to factory zero. Note that for a given session, the O command overrides the CO command. In the first image, the origin at factory offset '0' (centered).
223
224 [[image:LSS-servo-default.jpg]]
225
226 In the second image, the origina, as well as the angular range (explained below) have been shifted by 240.0 degrees:
227
228 [[image:LSS-servo-origin.jpg]]
229
230 Origin Offset Query (**QO**)
231
232 Example: #5QO<cr> Returns: *5QO-13
233
234 This allows you to query the angle (in tenths of degrees) of the origin in relation to the factory zero position.
235
236 Configure Origin Offset (**CO**)
237
238 Example: #5CO-24<cr>
239
240 This command allows you to change the origin of the servo in relation to the factory zero position in EEPROM. The setting will be saved upon servo reset / power cycle. Origin offset configuration commands are not cumulative and always relate to factory zero. The new origin is also used in RC mode.
241
242 ====== __7. Angular Range (**AR**)__ ======
243
244 Example: #5AR1800<cr>
245
246 This command allows you to temporarily change the total angular range of the servo in tenths of degrees. This applies to the Position in Pulse (P) command and RC mode. The default for (P) and RC mode is 1800 (180.0 degrees total, or ±90.0 degrees). In the first image,
247
248 [[image:LSS-servo-default.jpg]]
249
250 Here, the angular range has been restricted to 180.0 degrees, or -90.0 to +90.0. The center has remained unchanged.
251
252 [[image:LSS-servo-ar.jpg]]
253
254 The angular range action command (ex. #5AR1800<cr>) and origin offset action command (ex. #5O-1200<cr>) an be used to move both the center and limit the angular range:
255
256 [[image:LSS-servo-ar-o-1.jpg]]
257
258 Query Angular Range (**QAR**)
259
260 Example: #5QAR<cr> might return *5AR2756
261
262 Configure Angular Range (**CAR**)
263
264 This command allows you to change the total angular range of the servo in tenths of degrees in EEPROM. The setting will be saved upon servo reset / power cycle.
265
266 ====== __8. Position in Pulse (**P**)__ ======
267
268 Example: #5P2334<cr>
269
270 The position in PWM pulses was retained in order to be backward compatible with the SSC-32 / 32U protocol. This relates the desired angle with an RC standard PWM pulse and is further explained in the SSC-32 and SSC-32U manuals found on Lynxmotion.com. Without any modifications to configuration considered, and a ±90.0 degrees standard range where 1500 microseconds is centered, a pulse of 2334 would set the servo to 165.1 degrees. Valid values for P are [500, 2500]. Values outside this range are corrected to end points.
271
272 Query Position in Pulse (**QP**)
273
274 Example: #5QP<cr> might return *5QP2334
275
276 This command queries the current angular position in PWM "units". The user must take into consideration that the response includes any angular range and origin configurations in order to determine the actual angle. 
277 Valid values for QP are {-500, [500, 2500], -2500}. Values outside the [500, 2500] range are given a negative corresponding end point value to indicate they are out of bounds (note that if the servo is physically located at one of the endpoints, it may return a negative number if it is a fraction of a degree beyond the position).
278
279 ====== __9. Position in Degrees (**D**)__ ======
280
281 Example: #5PD1456<cr>
282
283 This moves the servo to an angle of 145.6 degrees, where the center (0) position is centered. Negative values (ex. -176 representing -17.6 degrees) are used. A full circle would be from -1800 to 1800 degrees. A value of 2700 would be the same angle as -900, except the servo would move in a different direction.
284
285 Larger values are permitted and allow for multi-turn functionality using the concept of virtual position.
286
287 Query Position in Degrees (**QD**)
288
289 Example: #5QD<cr> might return *5QD132<cr>
290
291 This means the servo is located at 13.2 degrees.
292
293 ====== __10. Wheel Mode in Degrees (**WD**)__ ======
294
295 Ex: #5WD900<cr>
296
297 This command sets the servo to wheel mode where it will rotate in the desired direction at the selected speed. The example above would have the servo rotate at 90.0 degrees per second clockwise (assuming factory default configurations).
298
299 Query Wheel Mode in Degrees (**QWD**)
300
301 Ex: #5QWD<cr> might return *5QWD900<cr>
302
303 The servo replies with the angular speed in tenths of degrees per second. A negative sign would indicate the opposite direction (for factory default a negative value would be counter clockwise).
304
305 ====== __11. Wheel Mode in RPM (**WR**)__ ======
306
307 Ex: #5WR40<cr>
308
309 This command sets the servo to wheel mode where it will rotate in the desired direction at the selected rpm. Wheel mode (a.k.a. "continuous rotation") has the servo operate like a geared DC motor. The servo's maximum rpm cannot be set higher than its physical limit at a given voltage. The example above would have the servo rotate at 40 rpm clockwise (assuming factory default configurations).
310
311 Query Wheel Mode in RPM (**QWR**)
312
313 Ex: #5QWR<cr> might return *5QWR40<cr>
314
315 The servo replies with the angular speed in rpm. A negative sign would indicate the opposite direction (for factory default a negative value would be counter clockwise).
316
317 ====== __12. Speed in Degrees (**SD**)__ ======
318
319 Ex: #5SD1800<cr>
320
321 This command sets the servo's maximum speed for action commands in tenths of degrees per second for that session. In the example above, the servo's maximum speed for that session would be set to 180.0 degrees per second. Therefore maximum speed for actions can be set "on the fly". The servo's maximum speed cannot be set higher than its physical limit at a given voltage. SD overrides CSD (described below) for that session. Upon reset or power cycle, the servo reverts to the value associated with CSD as described below. Note that SD and SR (described below) are effectively the same, but allow the user to specify the speed in either unit. The last command (either SR or SD) is what the servo uses for that session.
322
323 Query Speed in Degrees (**QSD**)
324
325 Ex: #5QSD<cr> might return *5QSD1800<cr>
326
327 By default QSD will return the current session value, which is set to the value of CSD as reset/power cycle and changed whenever a SD/SR command is processed.
328 If #5QSD1<cr> is sent, the configured maximum speed (CSD value) will be returned instead. You can also query the current speed using "2" and the current target travel speed using "3". See the table below for an example:
329
330 |**Command sent**|**Returned value (1/10 °)**
331 |ex: #5QSD<cr>|Session value for maximum speed (set by latest SD/SR command)
332 |ex: #5QSD1<cr>|Configured maximum speed  (set by CSD/CSR)
333 |ex: #5QSD2<cr>|Instantaneous speed (same as QWD)
334 |ex: #5QSD3<cr>|Target travel speed
335
336 Configure Speed in Degrees (**CSD**)
337
338 Ex: #5CSD1800<cr>
339
340 Using the CSD command sets the servo's maximum speed which is saved in EEPROM. In the example above, the servo's maximum speed will be set to 180.0 degrees per second. When the servo is powered on (or after a reset), the CSD value is used. Note that CSD and CSR (described below) are effectively the same, but allow the user to specify the speed in either unit. The last command (either CSR or CSD) is what the servo uses for that session.
341
342 ====== __13. Speed in RPM (**SR**)__ ======
343
344 Ex: #5SD45<cr>
345
346 This command sets the servo's maximum speed for action commands in rpm for that session. In the example above, the servo's maximum speed for that session would be set to 45rpm. Therefore maximum speed for actions can be set "on the fly". The servo's maximum speed cannot be set higher than its physical limit at a given voltage. SD overrides CSD (described below) for that session. Upon reset or power cycle, the servo reverts to the value associated with CSD as described below. Note that SD (described above) and SR are effectively the same, but allow the user to specify the speed in either unit. The last command (either SR or SD) is what the servo uses for that session.
347
348 Query Speed in Degrees (**QSR**)
349
350 Ex: #5QSR<cr> might return *5QSR45<cr>
351
352 By default QSR will return the current session value, which is set to the value of CSR as reset/power cycle and changed whenever a SD/SR command is processed.
353 If #5QSR1<cr> is sent, the configured maximum speed (CSR value) will be returned instead. You can also query the current speed using "2" and the current target travel speed using "3". See the table below for an example:
354
355 |**Command sent**|**Returned value (1/10 °)**
356 |ex: #5QSR<cr>|Session value for maximum speed (set by latest SD/SR command)
357 |ex: #5QSR1<cr>|Configured maximum speed  (set by CSD/CSR)
358 |ex: #5QSR2<cr>|Instantaneous speed (same as QWR)
359 |ex: #5QSR3<cr>|Target travel speed
360
361 Configure Speed in RPM (**CSR**)
362
363 Ex: #5CSR45<cr>
364
365 Using the CSR command sets the servo's maximum speed which is saved in EEPROM. In the example above, the servo's maximum speed will be set to 45rpm. When the servo is powered on (or after a reset), the CSR value is used. Note that CSD and CSR are effectively the same, but allow the user to specify the speed in either unit. The last command (either CSR or CSD) is what the servo uses for that session.
366
367 ====== __14. Angular Stiffness (**AS**)__ ======
368
369 The servo's rigidity / angular stiffness can be thought of as (though not identical to) a damped spring in which the value affects the stiffness and embodies how much, and how quickly the servo tried keep the requested position against changes.
370
371 A positive value of "angular stiffness":
372
373 * The more torque will be applied to try to keep the desired position against external input / changes
374 * The faster the motor will reach its intended travel speed and the motor will decelerate faster and nearer to its target position
375
376 A negative value on the other hand:
377
378 * Causes a slower acceleration to the travel speed, and a slower deceleration
379 * Allows the target position to deviate more from its position before additional torque is applied to bring it back
380
381 The default value is zero and the effect becomes extreme by -4, +4. There are no units, only integers between -4 to 4. Greater values produce increasingly erratic behavior.
382
383 Ex: #5AS-2<cr>
384
385 This reduces the angular stiffness to -2 for that session, allowing the servo to deviate more around the desired position. This can be beneficial in many situations such as impacts (legged robots) where more of a "spring" effect is desired. Upon reset, the servo will use the value stored in memory, based on the last configuration command.
386
387 Ex: #5QAS<cr>
388
389 Queries the value being used.
390
391 Ex: #5CAS<cr>
392
393 Writes the desired angular stiffness value to memory.
394
395 ====== __15. Angular Hold Stiffness (**AH**)__ ======
396
397 The angular holding stiffness determines the servo's ability to hold a desired position under load. Values can be from -10 to 10, with the default being 0. Note that negative values mean the final position can be easily deflected.
398
399 Ex: #5AH3<cr>
400
401 This sets the holding stiffness for servo #5 to 3 for that session.
402
403 Query Angular Hold Stiffness (**QAH**)
404
405 Ex: #5QAH<cr> might return *5QAH3<cr>
406
407 This returns the servo's angular holding stiffness value.
408
409 Configure Angular Hold Stiffness (**CAH**)
410
411 Ex: #5CAH2<cr>
412
413 This writes the angular holding stiffness of servo #5 to 2 to EEPROM
414
415 ====== __15b: Angular Acceleration (**AA**)__ ======
416
417 {More details to come}
418
419 ====== __15c: Angular Deceleration (**AD**)__ ======
420
421 {More details to come}
422
423 ====== __15d: Motion Control (**EM**)__ ======
424
425 {More details to come}
426
427 ====== __16. RGB LED (**LED**)__ ======
428
429 Ex: #5LED3<cr>
430
431 This action sets the servo's RGB LED color for that session.The LED can be used for aesthetics, or (based on user code) to provide visual status updates. Using timing can create patterns.
432
433 0=OFF 1=RED 2=GREEN 3= BLUE 4=YELLOW 5=CYAN 6= 7=MAGENTA, 8=WHITE 
434
435 Query LED Color (**QLED**)
436
437 Ex: #5QLED<cr> might return *5QLED5<cr>
438
439 This simple query returns the indicated servo's LED color.
440
441 Configure LED Color (**CLED**)
442
443 Configuring the LED color via the CLED command sets the startup color of the servo after a reset or power cycle. Note that it also changes the session's LED color immediately as well.
444
445 ====== __17. Identification Number__ ======
446
447 A servo's identification number cannot be set "on the fly" and must be configured via the CID command described below. The factory default ID number for all servos is 0. Since smart servos are intended to be daisy chained, in order to respond differently from one another, the user must set different identification numbers. Servos with the same ID and baud rate will all receive and react to the same commands.
448
449 Query Identification (**QID**)
450
451 EX: #254QID<cr> might return *QID5<cr>
452
453 When using the query ID command, it is best to only have one servo connected and thus receive only one reply using the broadcast command (ID 254). Alternatively, pushing the button upon startup and temporarily setting the servo ID to 255 will still result in the servo responding with its "real" ID.
454
455 Configure ID (**CID**)
456
457 Ex: #4CID5<cr>
458
459 Setting a servo's ID in EEPROM is done via the CID command. All servos connected to the same serial bus will be assigned that ID. In most situations each servo must be set a unique ID, which means each servo must be connected individually to the serial bus and receive a unique CID number. It is best to do this before the servos are added to an assembly. Numbered stickers are provided to distinguish each servo after their ID is set, though you are free to use whatever alternative method you like.
460
461 ====== __18. Baud Rate__ ======
462
463 A servo's baud rate cannot be set "on the fly" and must be configured via the CB command described below. The factory default baud rate for all servos is 9600. Since smart servos are intended to be daisy chained, in order to respond to the same serial bus, all servos in that project should ideally be set to the same baud rate. Setting different baud rates will have the servos respond differently and may create issues. Available baud rates are: 9.6 kbps, 19.2 kbps, 38.4 kbps, 57.6 kbps, 115.2 kbps, 230.4 kbps, 250.0 kbps, 460.8 kbps, 500.0 kbps, 750.0 kbps*, 921.6 kbps*. Servos are shipped with a baud rate set to 9600. The baud rates are currently restricted to those above.
464 \*: Current tests reveal baud rates above 500 kbps are unstable and can cause timeouts. Please keep this in mind if using those / testing them out.
465
466 Query Baud Rate (**QB**)
467
468 Ex: #5QB<cr> might return *5QB9600<cr>
469
470 Querying the baud rate is used simply to confirm the CB configuration command before the servo is power cycled.
471
472 Configure Baud Rate (**CB**)
473
474 Ex: #5CB9600<cr>
475
476 Sending this command will change the baud rate associated with servo ID 5 to 9600 bits per second.
477
478 ====== __19. Gyre Rotation Direction__ ======
479
480 "Gyre" is defined as a circular course or motion. The effect of changing the gyre direction is as if you were to use a mirror image of a circle. CW = 1; CCW = -1. The factory default is clockwise (CW).
481
482 {images showing before and after with AR and Origin offset}
483
484 Query Gyre Direction (**QG**)
485
486 Ex: #5QG<cr> might return *5QG-1<cr>
487
488 The value returned above means the servo is in a counter-clockwise gyration.
489
490 Configure Gyre (**CG**)
491
492 Ex: #5CG-1<cr>
493
494 This changes the gyre direction as described above and also writes to EEPROM.
495
496 ====== __20. First / Initial Position (pulse)__ ======
497
498 In certain cases, a user might want to have the servo move to a specific angle upon power up. We refer to this as "first position". The factory default has no first position value stored in EEPROM and therefore upon power up, the servo remains limp until a position (or hold command) is assigned. FP and FD are different in that FP is used for RC mode only, whereas FD is used for smart mode only.
499
500 Query First Position in Pulses (**QFP**)
501
502 Ex: #5QFP<cr> might return *5QFP1550<cr>
503
504 The reply above indicates that servo with ID 5 has a first position pulse of 1550 microseconds. If no first position has been set, servo will respond with DIS ("disabled").
505
506 Configure First Position in Pulses (**CFP**)
507
508 Ex: #5CP1550<cr>
509
510 This configuration command means the servo, when set to RC mode, will immediately move to an angle equivalent to having received an RC pulse of 1550 microseconds upon power up. Sending a CFP command without a number results in the servo remaining limp upon power up (i.e. disabled).
511
512 ====== __21. First / Initial Position (Degrees)__ ======
513
514 In certain cases, a user might want to have the servo move to a specific angle upon power up. We refer to this as "first position". The factory default has no first position value stored in EEPROM and therefore upon power up, the servo remains limp until a position (or hold command) is assigned. FP and FD are different in that FP is used for RC mode only, whereas FD is used for smart mode only.
515
516 Query First Position in Degrees (**QFD**)
517
518 Ex: #5QFD<cr> might return *5QFD64<cr>
519
520 The reply above indicates that servo with ID 5 has a first position pulse of 1550 microseconds.
521
522 Configure First Position in Degrees (**CFD**)
523
524 Ex: #5CD64<cr>
525
526 This configuration command means the servo, when set to smart mode, will immediately move to 6.4 degrees upon power up. Sending a CFD command without a number results in the servo remaining limp upon power up.
527
528 ====== __22. Query Target Position in Degrees (**QDT**)__ ======
529
530 Ex: #5QDT<cr> might return *5QDT6783<cr>
531
532 The query target position command returns the target angle during and after an action which results in a rotation of the servo horn. In the example above, the servo is rotating to a virtual position of 678.3 degrees. Should the servo not have a target position or be in wheel mode, it will respond without a number (Ex: *5QDT<cr>).
533
534 ====== __23. Query Model String (**QMS**)__ ======
535
536 Ex: #5QMS<cr> might return *5QMSLSS-HS1cr>
537
538 This reply means the servo model is LSS-HS1, meaning a high speed servo, first revision.
539
540 ====== __23b. Query Model (**QM**)__ ======
541
542 Ex: #5QM<cr> might return *5QM68702699520cr>
543
544 This reply means the servo model is 0xFFF000000 or 100, meaning a high speed servo, first revision.
545
546 ====== __24. Query Serial Number (**QN**)__ ======
547
548 Ex: #5QN<cr> might return *5QN~_~_<cr>
549
550 The number in the response is the servo's serial number which is set and cannot be changed.
551
552 ====== __25. Query Firmware (**QF**)__ ======
553
554 Ex: #5QF<cr> might return *5QF11<cr>
555
556 The integer in the reply represents the firmware version with one decimal, in this example being 1.1
557
558 ====== __26. Query Status (**Q**)__ ======
559
560 Ex: #5Q<cr> might return *5Q6<cr>, which indicates the motor is holding a position.
561
562 |*Value returned|**Status**|**Detailed description**
563 |ex: *5Q0<cr>|Unknown|LSS is unsure
564 |ex: *5Q1<cr>|Limp|Motor driving circuit is not powered and horn can be moved freely
565 |ex: *5Q2<cr>|Free moving|Motor driving circuit is not powered and horn can be moved freely
566 |ex: *5Q3<cr>|Accelerating|Increasing speed from rest (or previous speeD) towards travel speed
567 |ex: *5Q4<cr>|Traveling|Moving at a stable speed
568 |ex: *5Q5<cr>|Decelerating|Decreasing from travel speed towards final position.
569 |ex: *5Q6<cr>|Holding|Keeping current position
570 |ex: *5Q7<cr>|Stepping|Special low speed mode to maintain torque
571 |ex: *5Q8<cr>|Outside limits|{More details coming soon}
572 |ex: *5Q9<cr>|Stuck|Motor cannot perform request movement at current speed setting
573 |ex: *5Q10<cr>|Blocked|Similar to stuck, but the motor is at maximum duty and still cannot move (i.e.: stalled)
574
575 ====== __27. Query Voltage (**QV**)__ ======
576
577 Ex: #5QV<cr> might return *5QV11200<cr>
578
579 The number returned has one decimal, so in the case above, servo with ID 5 has an input voltage of 11.2V (perhaps a three cell LiPo battery).
580
581 ====== __28. Query Temperature (**QT**)__ ======
582
583 Ex: #5QT<cr> might return *5QT564<cr>
584
585 The units are in tenths of degrees Celcius, so in the example above, the servo's internal temperature is 56.4 degrees C. To convert from degrees Celcius to degrees Farenheit, multiply by 1.8 and add 32. Therefore 56.4C = 133.52F.
586
587 ====== __29. Query Current (**QC**)__ ======
588
589 Ex: #5QC<cr> might return *5QC140<cr>
590
591 The units are in milliamps, so in the example above, the servo is consuming 140mA, or 0.14A.
592
593 ====== __30. RC Mode (**CRC**)__ ======
594
595 This command puts the servo into RC mode (position or continuous), where it will only respond to RC pulses. Note that because this is the case, the servo will no longer accept serial commands. The servo can be placed back into smart mode by using the button menu.
596
597 |**Command sent**|**Note**
598 |ex: #5CRC<cr>|Stay in smart mode.
599 |ex: #5CRC1<cr>|Change to RC position mode.
600 |ex: #5CRC2<cr>|Change to RC continuous (wheel) mode.
601 |ex: #5CRC*<cr>|Where * is any number or value. Stay in smart mode.
602
603 EX: #5CRC<cr>
604
605 ====== __31. RESET__ ======
606
607 Ex: #5RESET<cr> or #5RS<cr>
608
609 This command does a "soft reset" (no power cycle required) and reverts all commands to those stored in EEPROM (i.e. configuration commands).
610
611 ====== __32. DEFAULT & CONFIRM__ ======
612
613 Ex: #5DEFAULT<cr>
614
615 This command sets in motion the reset all values to the default values included with the version of the firmware installed on that servo. The servo then waits for the CONFIRM command. Any other command received will cause the servo to exit the DEFAULT function.
616
617 EX: #5DEFAULT<cr> followed by #5CONFIRM<cr>
618
619 Since it it not common to have to restore all configurations, a confirmation command is needed after a firmware command is sent. Should any command other than CONFIRM be received by the servo after the firmware command has been received, it will leave the firmware action.
620
621 Note that after the CONFIRM command is sent, the servo will automatically perform a RESET.
622
623 ====== __33. UPDATE & CONFIRM__ ======
624
625 Ex: #5UPDATE<cr>
626
627 This command sets in motion the equivalent of a long button press when the servo is not powered in order to enter firmware update mode. This is useful should the button be broken or inaccessible. The servo then waits for the CONFIRM command. Any other command received will cause the servo to exit the UPDATE function.
628
629 EX: #5UPDATE<cr> followed by #5CONFIRM<cr>
630
631 Since it it not common to have to update firmware, a confirmation command is needed after an UPDATE command is sent. Should any command other than CONFIRM be received by the servo after the firmware command has been received, it will leave the firmware action.
632
633 Note that after the CONFIRM command is sent, the servo will automatically perform a RESET.
Copyright RobotShop 2018