3
4 {{toc depth="3"/}}
5
6 = Serial Protocol Concept =
7
8 The custom Lynxmotion Smart Servo (LSS) serial protocol was created in order to be as simple and straightforward as possible from a user perspective ("human readable format"), while at the same time compact and robust yet highly versatile. The protocol was based on Lynxmotion's SSC-32 RC servo controller and almost everything one might expect to be able to configure for a smart servo motor is available.
9
10 In order to have servos react differently when commands are sent to all servos in a serial bus, the first step a user should take is to assign a different ID number to each servo (explained below). Once this has been done, only the servo(s) which have been assigned to the ID sent as part of the command will follow that command. There is currently no CRC / checksum implemented as part of the protocol.
11
12 == Session ==
13
14 A "session" is defined as the time between when the servo is powered ON to when it is powered OFF or reset.
15
16 Note that for a given session, the action related to a specific commands overrides the stored value in EEPROM.
17
18 == Action Commands ==
19
20 Action commands tell the servo, within that session, to do something (i.e. "take an action"). The types of action commands which can be sent are described below, and they cannot be combined with other commands such as queries or configurations. Only one action command can be sent at a time. Action commands are session-specific, therefore once a servo is power cycled, it will not have any "memory" of previous actions or virtual positions (described below on this page). Action commands are sent serially to the servo's Rx pin and must be sent in the following format:
21
22 1. Start with a number sign # (U+0023)
23 1. Servo ID number as an integer
24 1. Action command (one to three letters, no spaces, capital or lower case)
25 1. Action value in the correct units with no decimal
26 1. End with a control / carriage return '<cr>'
27
28 (((
29 Ex: #5PD1443<cr>
30
31 This sends a serial command to all servo's Rx pins which are connected to the bus and only servo(s) with ID #5 will move to a position in tenths of degrees ("PD") of 144.3 degrees. Any servo on the bus which does not have ID 5 will take no action when receiving this command.
32
33 == Action Modifiers ==
34
35 Only two commands can be used as action modifiers: Timed Move (T) and Speed (S) described below. Action modifiers can only be used with certain action commands. The format to include a modifier is:
36
37 1. Start with a number sign # (U+0023)
38 1. Servo ID number as an integer
39 1. Action command (one to three letters, no spaces, capital or lower case)
40 1. Action value in the correct units with no decimal
41 1. Modifier command (one letter)
42 1. Modifier value in the correct units with no decimal
43 1. End with a control / carriage return '<cr>'
44
45 Ex: #5P1456T1263<cr>
46
47 This results in the servo with ID #5 rotating from the current angular position to a pulse position ("P") of 1456 in a time ("T") of 1263 milliseconds.
48 )))
49
50 == Query Commands ==
51
52 Query commands request information from the servo. They are received via the Rx pin of the servo, and the servo's reply is sent via the servo's Tx pin. Using separate lines for Tx and Rx is called "full duplex". Query commands are also similar to action and configuration commands and must use the following format:
53
54 1. Start with a number sign # (U+0023)
55 1. Servo ID number as an integer
56 1. Query command (one to three letters, no spaces, capital or lower case)
57 1. End with a control / carriage return '<cr>'
58
59 (((
60 Ex: #5QD<cr>Query position in degrees for servo #5
61 )))
62
63 (((
64 The query will return a serial string (almost instantaneously) via the servo's Tx pin with the following format:
65
66 1. Start with an asterisk * (U+002A)
67 1. Servo ID number as an integer
68 1. Query command (one to three letters, no spaces, capital letters)
69 1. The reported value in the units described, no decimals.
70 1. End with a control / carriage return '<cr>'
71
72 There is currently no option to control how fast a servo replies after it has received a query command, therefore when sending a query command to the bus, the controller should be prepared to immediately "listen" for and parse the reply. Sending multiple queries on a bus in fast succession may result in replies overlapping and giving incorrect or corrupt data. As such, the controller should receive a reply before sending a new command. A reply to the query sent above might be:
73
74 (((
75 Ex: *5QD1443<cr>
76 )))
77
78 This indicates that servo #5 is currently at 144.3 degrees (1443 tenths of degrees).
79
80 == Configuration Commands ==
81
82 Configuration commands and corresponding values affect a servo's defaults which are written to and read from the servo's EEPROM. These configurations are retained in memory after the servo is reset or power is cut / lost. Some configuration commands affect the session, while others do not. In the Command table below, the column "Session" denotes if the configuration command affects the session.. Not all action commands have a corresponding configuration command and vice versa. More information about which configuration commands are retained when in RC mode can be found on the [[LSS - RC PWM page>>doc:Lynxmotion Smart Servo (LSS).LSS - RC PWM.WebHome]]. Configuration commands are not cumulative, in that if two configurations are sent, one after the next, only the last configuration is used and stored. The format to send a configuration command is identical to that of an action command:
83
84 1. Start with a number sign # (U+0023)
85 1. Servo ID number as an integer
86 1. Configuration command (two to three letters, no spaces, capital or lower case)
87 1. Configuration value in the correct units with no decimal
88 1. End with a control / carriage return '<cr>'
89
90 Ex: #5CO-50<cr>
91
92 This configures an absolute origin offset ("CO") with respect to factory origin to servo with ID #5 and changes the offset for that session to -5.0 degrees (50 tenths of degrees). Once the servo is powered off and then powered on, zeroing the servo will cause it to move to -5.0 degrees with respect to the factory origin and report its position as 0 degrees. Configuration commands can be undone / reset either by sending the servo's default value for that configuration, or by doing a factory reset (clears all configurations) described below.
93
94 **Session vs Configuration Query**
95
96 By default, the query command returns the sessions' value. Should no action commands have been sent to change the session value, it will return the value saved in EEPROM which will either be the servo's default, or modified with a configuration command. In order to query the value stored in EEPROM (configuration), add a '1' to the query command:
97
98 Ex: #5CSR20<cr> immediately sets the maximum speed for servo #5 to 20rpm (explained below) and changes the value in memory.
99
100 After RESET, a command of #5SR4<cr> sets the session's speed to 4rpm, but does not change the configuration value in memory. Therefore:
101
102 #5QSR<cr> would return *5QSR4<cr> which represents the value for that session, whereas
103
104 #5QSR1<cr> would return *5QSR20<cr> which represents the value in EEPROM
105
106 == Virtual Angular Position ==
107
108 The ability to store a "virtual angular position" is a feature which allows for rotation beyond 360 degrees, permitting multiple rotations of the output horn, moving the center position and more. In virtual position mode, the "absolute position" would be the angle of the output shaft with respect to a 360.0 degree circle, and can be obtained by taking the modulus (with respect to 360 degrees) of the value. For example if the virtual position is reported as 15335 (or 1533.5 degrees), taking the modulus would give 93.5 degrees (3600 * 4 + 935 = 15335) as the absolute position (assuming no origin offset).
109
110 [[image:LSS-servo-positions.jpg]]
111
112 In this example, the gyre direction (explained below, a.k.a. "rotation direction") is positive (clockwise), and origin offset has not been modified. Each square represents 30 degrees. The following command is sent:
113
114 #1D-300<cr> This causes the servo to move to -30.0 degrees (green arrow)
115
116 #1D2100<cr> This second position command is sent to the servo, which moves it to 210.0 degrees (orange arrow)
117
118 #1D-4200<cr> This next command rotates the servo counterclockwise to a position of -420 degrees (red arrow), which means one full rotation of 360 degrees plus 60.0 degrees (420.0 - 360.0), with a virtual position of -420.0 degrees.
119
120 Although the final physical position would be the same as if the servo were commanded to move to -60.0 degrees, the servo is in fact at -420.0 degrees.
121
122 #1D4800<cr> This new command is sent which would then cause the servo to rotate from -420.0 degrees to 480.0 degrees (blue arrow), which would be a total of 900 degrees of clockwise rotation, or 2.5 complete rotations.
123
124 #1D3300<cr> would cause the servo to rotate from 480.0 degrees to 330.0 degrees (yellow arrow).
125
126 If / once the servo loses power or is power cycled, it also loses the virtual position associated with that session. For example, if the virtual position was 480.0 degrees before power is cycled, upon power up the servo's position will be read as +120.0 degrees from zero (assuming center position has not been modified).
127 )))
128
129 = Command List =
130
131 |= #|=Description|= Action|= Query|= Config|=Session|= RC|= Serial|= Units|=(% style="width: 510px;" %) Notes|=(% style="width: 113px;" %)Default Value
132 | 1|[[**L**imp>>||anchor="H1.Limp28L29"]]| L| | | | | ✓|none|(% style="width:510px" %) |(% style="text-align:center; width:113px" %)
133 | 2|[[**H**alt & **H**old>>||anchor="H2.Halt26Hold28H29"]]| H| | | | | ✓|none|(% style="width:510px" %) |(% style="text-align:center; width:113px" %)
134 | 3|[[**T**imed move>>||anchor="H3.Timedmove28T29"]]| T| | | | | ✓|milliseconds|(% style="width:510px" %) Modifier only for {P, D, MD}|(% style="text-align:center; width:113px" %)
135 | 4|[[**S**peed>>||anchor="H4.Speed28S29"]]| S| | | | | ✓|microseconds per second|(% style="width:510px" %) Modifier only {P}|(% style="text-align:center; width:113px" %)
136 | 5|[[**M**ove in **D**egrees (relative)>>||anchor="H5.28Relative29MoveinDegrees28MD29"]]| MD| | | | | ✓|tenths of degrees (ex 325 = 32.5 degrees)|(% style="width:510px" %) |(% style="text-align:center; width:113px" %)
137 | 6|[[**O**rigin Offset>>||anchor="H6.OriginOffsetAction28O29"]]| O| QO|CO|✓| ✓| ✓|tenths of degrees (ex 91 = 9.1 degrees)|(% style="width:510px" %) |(% style="text-align:center; width:113px" %)(((
138 0
139 )))
140 | 7|[[**A**ngular **R**ange>>||anchor="H7.AngularRange28AR29"]]| AR| QAR| CAR|✓| ✓| ✓|tenths of degrees |(% style="width:510px" %) |(% style="text-align:center; width:113px" %)(((
141 1800
142 )))
143 | 8|[[Position in **P**ulse>>||anchor="H8.PositioninPulse28P29"]]| P| QP| | | | ✓|microseconds|(% style="width:510px" %)(((
144 Inherited from SSC-32 serial protocol
145 )))|(% style="text-align:center; width:113px" %)
146 | 9|[[Position in **D**egrees>>||anchor="H9.PositioninDegrees28D29"]]| D| QD / QDT| | | | ✓|tenths of degrees |(% style="width:510px" %) |(% style="text-align:center; width:113px" %)
147 | 10|[[**W**heel mode in **D**egrees>>||anchor="H10.WheelModeinDegrees28WD29"]]| WD| QWD| | | | ✓|tenths of degrees per second (ex 248 = 24.8 degrees per second)|(% style="width:510px" %)A.K.A. "Speed mode" or "Continuous rotation"|(% style="text-align:center; width:113px" %)
148 | 11|[[**W**heel mode in **R**PM>>||anchor="H11.WheelModeinRPM28WR29"]]| WR| QWR| | | | ✓|revolutions per minute (rpm)|(% style="width:510px" %)A.K.A. "Speed mode" or "Continuous rotation"|(% style="text-align:center; width:113px" %)
149 | 12|[[Max **S**peed in **D**egrees>>||anchor="H12.SpeedinDegrees28SD29"]]| SD| QSD|CSD|✓| ✓| ✓|tenths of degrees per second |(% style="width:510px" %)(((
150 QSD: Add modifier "2" for instantaneous speed.
151
152 SD overwrites SR / CSD overwrites CSR and vice-versa.
153 )))|(% style="text-align:center; width:113px" %)Max per servo
154 | 13|[[Max **S**peed in **R**PM>>||anchor="H13.SpeedinRPM28SR29"]]| SR| QSR|CSR|✓| ✓| ✓|revolutions per minute (rpm)|(% style="width:510px" %)(((
155 QSR: Add modifier "2" for instantaneous speed
156
157 SR overwrites SD / CSR overwrites CSD and vice-versa.
158 )))|(% style="text-align:center; width:113px" %)Max per servo
159 | 14|[[**LED** Color>>||anchor="H16.RGBLED28LED29"]]| LED| QLED| CLED|✓| ✓| ✓|none (integer from 0 to 8)|(% style="width:510px" %)0=Off (black); 1=Red 2=Green; 3=Blue; 4=Yellow; 5=Cyan; 6=Magenta; 7=White;|(% style="text-align:center; width:113px" %)7
160 | 15|[[**G**yre direction (**G**)>>||anchor="H19.GyreRotationDirection"]]| G| QG| CG|✓| ✓| ✓|none |(% style="width:510px" %)Gyre / rotation direction: 1= CW (clockwise) -1 = CCW (counter-clockwise)|(% style="text-align:center; width:113px" %)1
161 | 16|[[**ID** #>>||anchor="H17.IdentificationNumber"]]| | QID| CID| | | ✓|none (integer from 0 to 250)|(% style="width:510px" %)Note: ID 254 is a "broadcast" which all servos respond to. |(% style="text-align:center; width:113px" %)0
162 | 17|[[**B**aud rate>>||anchor="H18.BaudRate"]]| | QB| CB| | | ✓|none (integer)|(% style="width:510px" %) |(% style="text-align:center; width:113px" %)9600
163 | 18|[[**F**irst Position (**P**ulse)>>||anchor="H20.First2InitialPosition28pulse29"]]| | QFP|CFP |X| ✓| ✓|none |(% style="width:510px" %)CFP overwrites CFD and vice-versa|(% style="text-align:center; width:113px" %)(((
164 Limp
165 )))
166 | 19|[[**F**irst Position (**D**eg)>>||anchor="H21.First2InitialPosition28Degrees29"]]| | QFD|CFD|X| ✓| ✓|none |(% style="width:510px" %)CFD overwrites CFP and vice-versa|(% style="text-align:center; width:113px" %)Limp
167 | 21|[[**M**odel **S**tring>>||anchor="H23.QueryModelString28QMS29"]]| | QMS| | | | |none (string)|(% style="width:510px" %) Returns the type of servo (ST, HS, HT)|(% style="text-align:center; width:113px" %)
168 | 22|[[Serial **N**umber>>||anchor="H24.QuerySerialNumber28QN29"]]| | QN| | | | |none (integer)|(% style="width:510px" %) Returns the unique serial number for that servo|(% style="text-align:center; width:113px" %)
169 | 23|[[**F**irmware version>>||anchor="H25.QueryFirmware28QF29"]]| | QF| | | | |none (integer)|(% style="width:510px" %) |(% style="text-align:center; width:113px" %)
170 | 24|[[**Q**uery (gen. status)>>||anchor="H26.QueryStatus28Q29"]]| | Q| | | | ✓|none (integer from 1 to 8)|(% style="width:510px" %) See command description for details|(% style="text-align:center; width:113px" %)
171 | 25|[[**V**oltage>>||anchor="H27.QueryVoltage28QV29"]]| | QV| | | | ✓|millivolts (ex 5936 = 5936mV = 5.936V)|(% style="width:510px" %) |(% style="text-align:center; width:113px" %)
172 | 26|[[**T**emperature>>||anchor="H28.QueryTemperature28QT29"]]| | QT| | | | ✓|tenths of degrees Celsius|(% style="width:510px" %)Max temp before error: 85°C (servo goes limp)|(% style="text-align:center; width:113px" %)
173 | 27|[[**C**urrent>>||anchor="H29.QueryCurrent28QC29"]]| | QC| | | | ✓|milliamps (ex 200 = 0.2A)|(% style="width:510px" %) |(% style="text-align:center; width:113px" %)
174 | 28|[[**RC** Mode>>||anchor="H30.RCMode28CRC29"]] - Position| | |CRC1|✓| | ✓|none|(% style="width:510px" %)(((
175 Change to RC position mode. To revert to smart mode, use the button menu.
176 )))|(% style="text-align:center; width:113px" %)Serial
177 | 29|[[**RC** Mode>>||anchor="H30.RCMode28CRC29"]] - Wheel| | |CRC2|✓| | ✓| |(% style="width:510px" %)Change to RC wheel mode. To revert to smart mode, use the button menu.|(% style="text-align:center; width:113px" %)Serial
178 | 30|[[**RESET**>>||anchor="H31.RESET"]]| | | | | | ✓|none|(% style="width:510px" %)Soft reset. See command for details.|(% style="text-align:center; width:113px" %)
179 | 31|[[**DEFAULT**>>||anchor="H32.DEFAULTA026CONFIRM"]]| | | | | |✓|none|(% style="width:510px" %)Revert to firmware default values. See command for details|(% style="text-align:center; width:113px" %)
180 | 32|[[**UPDATE**>>||anchor="H33.UPDATEA026CONFIRM"]]| | | | | |✓|none|(% style="width:510px" %)Update firmware. See command for details.|(% style="text-align:center; width:113px" %)
181
182 == Advanced ==
183
184 |= #|=Description|= Action|= Query|= Config|=Session|= RC|= Serial|= Units|=(% style="width: 510px;" %) Notes|=(% style="width: 113px;" %)Default Value
185 | A1|[[**A**ngular **S**tiffness>>||anchor="H14.AngularStiffness28AS29"]]| AS|QAS|CAS|✓| ✓| ✓|none (integer -4 to +4)|(% style="width:510px" %)Suggested values are between 0 to +4|(% style="text-align:center; width:113px" %)0
186 | A2|[[**A**ngular **H**olding Stiffness>>||anchor="H15.AngularHoldStiffness28AH29"]]|AH|QAH|CAH|✓| | ✓|none (integer -10 to +10)|(% style="width:510px" %) |(% style="text-align:center; width:113px" %)1
187 | A3|[[**A**ngular **A**cceleration>>||anchor="H15b:AngularAcceleration28AA29"]]|AA|QAA|CAA|✓| | ✓|degrees per second squared|(% style="width:510px" %)Increments of 10 degrees per second squared|(% style="text-align:center; width:113px" %)
188 | A4|[[**A**ngular **D**eceleration>>||anchor="H15c:AngularDeceleration28AD29"]]|AD|QAD|CAD|✓| | ✓|degrees per second squared|(% style="width:510px" %)Increments of 10 degrees per second squared|(% style="text-align:center; width:113px" %)
189 | A5|[[**E**nable **M**otion Control>>||anchor="H15d:MotionControl28MC29"]]|EM|QEM| | | | ✓|none|(% style="width:510px" %)EM0 to disable motion control, EM1 to enable|(% style="text-align:center; width:113px" %)
190 | A6|[[**C**onfigure **L**ED **B**linking>>||anchor="H16b.ConfigureLEDBlinking28CLB29"]]| | | CLB| | ✓| |none (integer from 0 to 63)|(% style="width:510px" %)(((
191 0=No blinking, 63=Always blink;
192
193 Blink while: 1=Limp; 2=Holding 4=Accel; 8=Decel; 16=Free 32=Travel;
194 )))|(% style="text-align:center; width:113px" %)
195
196 == Details ==
197
198 ====== __1. Limp (**L**)__ ======
199
200 Example: #5L<cr>
201
202 This action causes the servo to go "limp". The microcontroller will still be powered, but the motor will not. As an emergency safety feature, should the robot not be doing what it is supposed to or risks damage, use the broadcast ID to set all servos limp #254L<cr>.
203
204 ====== __2. Halt & Hold (**H**)__ ======
205
206 Example: #5H<cr>
207
208 This action overrides whatever the servo might be doing at the time the command is received (accelerating, moving continuously etc.) and causes it to stop immediately and hold that angular position.
209
210 ====== __3. Timed move (**T**) modifier__ ======
211
212 Example: #5P1500T2500<cr>
213
214 Timed move can be used only as a modifier for a position (P, D, MD) actions. The units are in milliseconds, so a timed move of 2500 milliseconds would cause the servo to rotate from its current position to the desired position in 2.5 seconds. The onboard controller will attempt to ensure that the move is performed entirely at the desired velocity, though differences in torque may cause it to not be exact. This command is in place to ensure backwards compatibility with the SSC-32 / 32U protocol.
215
216 Note: If the calculated speed at which a servo must rotate for a timed move is greater than its maximum speed (which depends on voltage and load), then it will move at its maximum speed, and the time of the move may be longer than requested.
217
218 ====== __4. Speed (**S**) modifier__ ======
219
220 Example: #5P1500S750<cr>
221
222 This command is a modifier only for a position (P) action and determines the speed of the move in microseconds per second. A speed of 750 microseconds would cause the servo to rotate from its current position to the desired position at a speed of 750 microseconds per second. This command is in place to ensure backwards compatibility with the SSC-32 / 32U protocol.
223
224 ====== __5. (Relative) Move in Degrees (**MD**)__ ======
225
226 Example: #5MD123<cr>
227
228 The relative move command causes the servo to read its current position and move the specified number of tenths of degrees in the corresponding position. For example if the servo is set to rotate CW (default) and an MD command of 123 is sent to the servo, it will cause the servo to rotate clockwise by 12.3 degrees. Negative commands would cause the servo to rotate in the opposite configured direction.
229
230 ====== __6. Origin Offset Action (**O**)__ ======
231
232 Example: #5O2400<cr>
233
234 This command allows you to temporarily change the origin of the servo in relation to the factory zero position for that session. As with all action commands, the setting will be lost upon servo reset / power cycle. Origin offset commands are not cumulative and always relate to factory zero. In the first image, the origin at factory offset '0' (centered).
235
236 [[image:LSS-servo-default.jpg]]
237
238 In the second image, the origin, and the corresponding angular range (explained below) have been shifted by +240.0 degrees:
239
240 [[image:LSS-servo-origin.jpg]]
241
242 Origin Offset Query (**QO**)
243
244 Example: #5QO<cr> Returns: *5QO-13
245
246 This allows you to query the angle (in tenths of degrees) of the origin in relation to the factory zero position. In this example, the new origin is at -1.3 degrees from the factory zero.
247
248 Configure Origin Offset (**CO**)
249
250 Example: #5CO-24<cr>
251
252 This command allows you to change the origin of the servo in relation to the factory zero position in EEPROM. The setting will be saved upon servo reset / power cycle. Origin offset configuration commands are not cumulative and always relate to factory zero. The new origin is also used in RC mode. In the example, the new origin will be at -2.4 degrees from the factory zero.
253
254 ====== __7. Angular Range (**AR**)__ ======
255
256 Example: #5AR1800<cr>
257
258 This command allows you to temporarily change the total angular range of the servo in tenths of degrees. This applies to the Position in Pulse (P) command and RC mode. The default for (P) and RC mode is 1800 (180.0 degrees total, or ±90.0 degrees). The image below shows a standard -180.0 to +180.0 range, with no offset:
259
260 [[image:LSS-servo-default.jpg]]
261
262 Below, the angular range is restricted to 180.0 degrees, or -90.0 to +90.0. The center has remained unchanged.
263
264 [[image:LSS-servo-ar.jpg]]
265
266 Finally, the angular range action command (ex. #5AR1800<cr>) and origin offset action command (ex. #5O-1200<cr>) are used to move both the center and limit the angular range:
267
268 [[image:LSS-servo-ar-o-1.jpg]]
269
270 Query Angular Range (**QAR**)
271
272 Example: #5QAR<cr> might return *5AR1800, indicating the total angular range is 180.0 degrees.
273
274 Configure Angular Range (**CAR**)
275
276 This command allows you to change the total angular range of the servo in tenths of degrees in EEPROM. The setting will be saved upon servo reset / power cycle.
277
278 ====== __8. Position in Pulse (**P**)__ ======
279
280 Example: #5P2334<cr>
281
282 The position in PWM pulses was retained in order to be backward compatible with the SSC-32 / 32U protocol. This relates the desired angle with an RC standard PWM pulse and is further explained in the SSC-32 and SSC-32U manuals found on Lynxmotion.com. Without any modifications to configuration considered, and a ±90.0 degrees standard range where 1500 microseconds is centered, a pulse of 2334 would set the servo to 165.1 degrees. Valid values for P are [500, 2500]. Values outside this range are corrected to end points.
283
284 Query Position in Pulse (**QP**)
285
286 Example: #5QP<cr> might return *5QP2334
287
288 This command queries the current angular position in PWM "units". The user must take into consideration that the response includes any angular range and origin configurations in order to determine the actual angle. 
289 Valid values for QP are {-500, [500, 2500], -2500}. Values outside the [500, 2500] range are given a negative corresponding end point value to indicate they are out of bounds (note that if the servo is physically located at one of the endpoints, it may return a negative number if it is a fraction of a degree beyond the position).
290
291 ====== __9. Position in Degrees (**D**)__ ======
292
293 Example: #5PD1456<cr>
294
295 This moves the servo to an angle of 145.6 degrees, where the center (0) position is centered. Negative values (ex. -176 representing -17.6 degrees) are used. A full circle would be from -1800 to 1800 degrees. A value of 2700 would be the same angle as -900, except the servo would move in a different direction.
296
297 Larger values are permitted and allow for multi-turn functionality using the concept of virtual position.
298
299 Query Position in Degrees (**QD**)
300
301 Example: #5QD<cr> might return *5QD132<cr>
302
303 This means the servo is located at 13.2 degrees.
304
305 (% class="wikigeneratedid" id="H22.QueryTargetPositioninDegrees28QDT29" %)
306 Query Target Position in Degrees (**QDT**)
307
308 Ex: #5QDT<cr> might return *5QDT6783<cr>
309
310 The query target position command returns the target angle during and after an action which results in a rotation of the servo horn. In the example above, the servo is rotating to a virtual position of 678.3 degrees. Should the servo not have a target position or be in wheel mode, it will respond without a number (Ex: *5QDT<cr>).
311
312 ====== __10. Wheel Mode in Degrees (**WD**)__ ======
313
314 Ex: #5WD900<cr>
315
316 This command sets the servo to wheel mode where it will rotate in the desired direction at the selected speed. The example above would have the servo rotate at 90.0 degrees per second clockwise (assuming factory default configurations).
317
318 Query Wheel Mode in Degrees (**QWD**)
319
320 Ex: #5QWD<cr> might return *5QWD900<cr>
321
322 The servo replies with the angular speed in tenths of degrees per second. A negative sign would indicate the opposite direction (for factory default a negative value would be counter clockwise).
323
324 ====== __11. Wheel Mode in RPM (**WR**)__ ======
325
326 Ex: #5WR40<cr>
327
328 This command sets the servo to wheel mode where it will rotate in the desired direction at the selected rpm. Wheel mode (a.k.a. "continuous rotation") has the servo operate like a geared DC motor. The servo's maximum rpm cannot be set higher than its physical limit at a given voltage. The example above would have the servo rotate at 40 rpm clockwise (assuming factory default configurations).
329
330 Query Wheel Mode in RPM (**QWR**)
331
332 Ex: #5QWR<cr> might return *5QWR40<cr>
333
334 The servo replies with the angular speed in rpm. A negative sign would indicate the opposite direction (for factory default a negative value would be counter clockwise).
335
336 ====== __12. Max Speed in Degrees (**SD**)__ ======
337
338 Ex: #5SD1800<cr>
339
340 This command sets the servo's maximum speed for motion commands in tenths of degrees per second for that session. In the example above, the servo's maximum speed for that session would be set to 180.0 degrees per second. The servo's maximum speed cannot be set higher than its physical limit at a given voltage. The SD action command overrides CSD (described below) for that session. Upon reset or power cycle, the servo reverts to the value associated with CSD as described below. Note that SD and SR (described below) are effectively the same, but allow the user to specify the speed in either unit. The last command (either SR or SD) received is what the servo uses for that session.
341
342 Query Speed in Degrees (**QSD**)
343
344 Ex: #5QSD<cr> might return *5QSD1800<cr>
345
346 By default QSD will return the current session value, which is set to the value of CSD as reset/power cycle and changed whenever an SD/SR command is processed.
347 If #5QSD1<cr> is sent, the configured maximum speed (CSD value) will be returned instead. You can also query the current speed using "2" and the current target travel speed using "3". See the table below for an example:
348
349 |**Command sent**|**Returned value (1/10 °)**
350 |ex: #5QSD<cr>|Session value for maximum speed (set by latest SD/SR command)
351 |ex: #5QSD1<cr>|Configured maximum speed in EEPROM (set by CSD/CSR)
352 |ex: #5QSD2<cr>|Instantaneous speed (same as QWD)
353 |ex: #5QSD3<cr>|Target travel speed
354
355 Configure Speed in Degrees (**CSD**)
356
357 Ex: #5CSD1800<cr>
358
359 Using the CSD command sets the servo's maximum speed which is saved in EEPROM. In the example above, the servo's maximum speed will be set to 180.0 degrees per second. When the servo is powered on (or after a reset), the CSD value is used. Note that CSD and CSR (described below) are effectively the same, but allow the user to specify the speed in either unit. The last command (either CSR or CSD) is what the servo uses for that session.
360
361 ====== __13. Max Speed in RPM (**SR**)__ ======
362
363 Ex: #5SD45<cr>
364
365 This command sets the servo's maximum speed for motion commands in rpm for that session. In the example above, the servo's maximum speed for that session would be set to 45rpm. The servo's maximum speed cannot be set higher than its physical limit at a given voltage. SD overrides CSD (described below) for that session. Upon reset or power cycle, the servo reverts to the value associated with CSD as described below. Note that SD (described above) and SR are effectively the same, but allow the user to specify the speed in either unit. The last command (either SR or SD) received is what the servo uses for that session.
366
367 Query Speed in Degrees (**QSR**)
368
369 Ex: #5QSR<cr> might return *5QSR45<cr>
370
371 By default QSR will return the current session value, which is set to the value of CSR as reset/power cycle and changed whenever an SD/SR command is processed.
372 If #5QSR1<cr> is sent, the configured maximum speed (CSR value) will be returned instead. You can also query the current speed using "2" and the current target travel speed using "3". See the table below for an example:
373
374 |**Command sent**|**Returned value (1/10 °)**
375 |ex: #5QSR<cr>|Session value for maximum speed (set by latest SD/SR command)
376 |ex: #5QSR1<cr>|Configured maximum speed in EEPROM (set by CSD/CSR)
377 |ex: #5QSR2<cr>|Instantaneous speed (same as QWR)
378 |ex: #5QSR3<cr>|Target travel speed
379
380 Configure Speed in RPM (**CSR**)
381
382 Ex: #5CSR45<cr>
383
384 Using the CSR command sets the servo's maximum speed which is saved in EEPROM. In the example above, the servo's maximum speed will be set to 45rpm. When the servo is powered on (or after a reset), the CSR value is used. Note that CSD and CSR are effectively the same, but allow the user to specify the speed in either unit. The last command (either CSR or CSD) received is what the servo uses for that session.
385
386 ====== __14. LED Color (**LED**)__ ======
387
388 Ex: #5LED3<cr>
389
390 This action sets the servo's RGB LED color for that session.The LED can be used for aesthetics, or (based on user code) to provide visual status updates. Using timing can create patterns.
391
392 0=OFF 1=RED 2=GREEN 3= BLUE 4=YELLOW 5=CYAN 6= 7=MAGENTA, 8=WHITE 
393
394 Query LED Color (**QLED**)
395
396 Ex: #5QLED<cr> might return *5QLED5<cr>
397
398 This simple query returns the indicated servo's LED color.
399
400 Configure LED Color (**CLED**)
401
402 Configuring the LED color via the CLED command sets the startup color of the servo after a reset or power cycle. Note that it also changes the session's LED color immediately as well.
403
404 ====== __15. Gyre Rotation Direction (**G**)__ ======
405
406 "Gyre" is defined as a circular course or motion. The effect of changing the gyre direction is as if you were to use a mirror image of a circle. CW = 1; CCW = -1. The factory default is clockwise (CW).
407
408 Ex: #5G-1<cr>
409
410 This command will cause servo #5's positions to be inverted, effectively causing the servo to rotate in the opposite direction given the same command. For example in a 2WD robot, servos are often physically installed back to back, therefore setting one of the servos to a negative gyration, the same wheel command (ex WR30) to both servos will cause the robot to move forward or backward rather than rotate.
411
412 Query Gyre Direction (**QG**)
413
414 Ex: #5QG<cr> might return *5QG-1<cr>
415
416 The value returned above means the servo is in a counter-clockwise gyration.
417
418 Configure Gyre (**CG**)
419
420 Ex: #5CG-1<cr>
421
422 This changes the gyre direction as described above and also writes to EEPROM.
423
424 ====== __16. Identification Number (**ID** #)__ ======
425
426 A servo's identification number cannot be set "on the fly" and must be configured via the CID command described below. The factory default ID number for all servos is 0. Since smart servos are intended to be daisy chained, in order to respond differently from one another, the user must set different identification numbers. Servos with the same ID and baud rate will all receive and react to the same commands (assuming same baud rate).
427
428 Query Identification (**QID**)
429
430 EX: #254QID<cr> might return *QID5<cr>
431
432 When using the query ID command, it is best to only have one servo connected and thus receive only one reply. This is useful when you are not sure of the servo's ID, but don't want to change it. Using the broadcast command (ID 254) with only one servo will have that servo reply with its ID number (assuming the query is sent . Alternatively, pushing the button upon startup and temporarily setting the servo ID to 255 will still result in the servo responding with its "real" ID.
433
434 Configure ID (**CID**)
435
436 Ex: #4CID5<cr>
437
438 Setting a servo's ID in EEPROM is done via the CID command. All servos connected to the same serial bus will be assigned that ID. In most situations each servo must be set a unique ID, which means each servo must be connected individually to the serial bus and receive a unique CID number. It is best to do this before the servos are added to an assembly. Numbered stickers are provided to distinguish each servo after their ID is set, though you are free to use whatever alternative method you like. The servo must be RESET or power cycled in order for the new ID to take effect.
439
440 ====== __17. Baud Rate (B)__ ======
441
442 A servo's baud rate cannot be set "on the fly" and must be configured via the CB command described below. The factory default baud rate for all servos is 9600. Since smart servos are intended to be daisy chained, in order to respond to the same serial bus, all servos in a project should ideally be set to the same baud rate. Setting different baud rates will have the servos respond differently and may create issues. Available baud rates are: 9600 bps, 19200 bps, 38400 bps, 57600 bps, 115.2 kbps, 230.4 kbps, 250.0 kbps, 460.8 kbps, 500.0 kbps. Servos are shipped with a baud rate set to 9600. The baud rates are currently restricted to those above.
443
444 Query Baud Rate (**QB**)
445
446 Ex: #5QB<cr> might return *5QB9600<cr>
447
448 Since the command to query the baud rate must be done at the servo's existing baud rate, it can simply be used to confirm the CB configuration command was correctly received before the servo is power cycled and the new baud rate takes effect.
449
450 Configure Baud Rate (**CB**)
451
452 Important Note: the servo's current session retains the given baud rate and the new baud rate will only take effect when the servo is power cycled / RESET.
453
454 Ex: #5CB9600<cr>
455
456 Sending this command will change the baud rate associated with servo ID 5 to 9600 bits per second.
457
458 ====== __18. First Position (Pulse) (**FP**)__ ======
459
460 In certain cases, a user might want to have the servo move to a specific angle upon power up; we refer to this as "first position" (a.k.a. "initial position"). The factory default has no first position value stored in EEPROM and therefore upon power up, the servo remains limp until a position (or hold command) is assigned. FP and FD are different in that FP is used for RC mode only, whereas FD is used for smart mode only.
461
462 Query First Position in Pulses (**QFP**)
463
464 Ex: #5QFP<cr> might return *5QFP1550<cr>
465
466 The reply above indicates that servo with ID 5 has a first position pulse of 1550 microseconds. If no first position has been set, servo will respond with DIS ("disabled").
467
468 Configure First Position in Pulses (**CFP**)
469
470 Ex: #5CP1550<cr>
471
472 This configuration command means the servo, when set to RC mode, will immediately move to an angle equivalent to having received an RC pulse of 1550 microseconds upon power up. Sending a CFP command without a number (Ex. #5CFP<cr>) results in the servo remaining limp upon power up (i.e. disabled).
473
474 ====== __19. First / Initial Position (Degrees) (**FD**)__ ======
475
476 In certain cases, a user might want to have the servo move to a specific angle upon power up; we refer to this as "first position" (a.k.a. "initial position"). The factory default has no first position value stored in EEPROM and therefore upon power up, the servo remains limp until a position (or hold command) is assigned. FP and FD are different in that FP is used for RC mode only, whereas FD is used for smart mode only.
477
478 Query First Position in Degrees (**QFD**)
479
480 Ex: #5QFD<cr> might return *5QFD64<cr>
481
482 The reply above indicates that servo with ID 5 has a first position pulse of 1550 microseconds.
483
484 Configure First Position in Degrees (**CFD**)
485
486 Ex: #5CD64<cr>
487
488 This configuration command means the servo, when set to smart mode, will immediately move to 6.4 degrees upon power up. Sending a CFD command without a number (Ex. #5CFD<cr>) results in the servo remaining limp upon power up.
489
490 ====== __23. Query Model String (**QMS**)__ ======
491
492 Ex: #5QMS<cr> might return *5QMSLSS-HS1cr>
493
494 This reply means the servo model is LSS-HS1, meaning a high speed servo, first revision.
495
496 ====== __23b. Query Model (**QM**)__ ======
497
498 Ex: #5QM<cr> might return *5QM68702699520cr>
499
500 This reply means the servo model is 0xFFF000000 or 100, meaning a high speed servo, first revision.
501
502 ====== __24. Query Serial Number (**QN**)__ ======
503
504 Ex: #5QN<cr> might return *5QN~_~_<cr>
505
506 The number in the response is the servo's serial number which is set and cannot be changed.
507
508 ====== __25. Query Firmware (**QF**)__ ======
509
510 Ex: #5QF<cr> might return *5QF11<cr>
511
512 The integer in the reply represents the firmware version with one decimal, in this example being 1.1
513
514 ====== __26. Query Status (**Q**)__ ======
515
516 Ex: #5Q<cr> might return *5Q6<cr>, which indicates the motor is holding a position.
517
518 |*Value returned|**Status**|**Detailed description**
519 |ex: *5Q0<cr>|Unknown|LSS is unsure
520 |ex: *5Q1<cr>|Limp|Motor driving circuit is not powered and horn can be moved freely
521 |ex: *5Q2<cr>|Free moving|Motor driving circuit is not powered and horn can be moved freely
522 |ex: *5Q3<cr>|Accelerating|Increasing speed from rest (or previous speeD) towards travel speed
523 |ex: *5Q4<cr>|Traveling|Moving at a stable speed
524 |ex: *5Q5<cr>|Decelerating|Decreasing from travel speed towards final position.
525 |ex: *5Q6<cr>|Holding|Keeping current position
526 |ex: *5Q7<cr>|Stepping|Special low speed mode to maintain torque
527 |ex: *5Q8<cr>|Outside limits|{More details coming soon}
528 |ex: *5Q9<cr>|Stuck|Motor cannot perform request movement at current speed setting
529 |ex: *5Q10<cr>|Blocked|Similar to stuck, but the motor is at maximum duty and still cannot move (i.e.: stalled)
530
531 ====== __27. Query Voltage (**QV**)__ ======
532
533 Ex: #5QV<cr> might return *5QV11200<cr>
534
535 The number returned has one decimal, so in the case above, servo with ID 5 has an input voltage of 11.2V (perhaps a three cell LiPo battery).
536
537 ====== __28. Query Temperature (**QT**)__ ======
538
539 Ex: #5QT<cr> might return *5QT564<cr>
540
541 The units are in tenths of degrees Celcius, so in the example above, the servo's internal temperature is 56.4 degrees C. To convert from degrees Celcius to degrees Farenheit, multiply by 1.8 and add 32. Therefore 56.4C = 133.52F.
542
543 ====== __29. Query Current (**QC**)__ ======
544
545 Ex: #5QC<cr> might return *5QC140<cr>
546
547 The units are in milliamps, so in the example above, the servo is consuming 140mA, or 0.14A.
548
549 ====== __30. RC Mode (**CRC**)__ ======
550
551 This command puts the servo into RC mode (position or continuous), where it will only respond to RC pulses. Note that because this is the case, the servo will no longer accept serial commands. The servo can be placed back into smart mode by using the button menu.
552
553 |**Command sent**|**Note**
554 |ex: #5CRC<cr>|Stay in smart mode.
555 |ex: #5CRC1<cr>|Change to RC position mode.
556 |ex: #5CRC2<cr>|Change to RC continuous (wheel) mode.
557 |ex: #5CRC*<cr>|Where * is any number or value. Stay in smart mode.
558
559 EX: #5CRC<cr>
560
561 ====== __31. RESET__ ======
562
563 Ex: #5RESET<cr> or #5RS<cr>
564
565 This command does a "soft reset" (no power cycle required) and reverts all commands to those stored in EEPROM (i.e. configuration commands).
566
567 ====== __32. DEFAULT & CONFIRM__ ======
568
569 Ex: #5DEFAULT<cr>
570
571 This command sets in motion the reset all values to the default values included with the version of the firmware installed on that servo. The servo then waits for the CONFIRM command. Any other command received will cause the servo to exit the DEFAULT function.
572
573 EX: #5DEFAULT<cr> followed by #5CONFIRM<cr>
574
575 Since it it not common to have to restore all configurations, a confirmation command is needed after a firmware command is sent. Should any command other than CONFIRM be received by the servo after the firmware command has been received, it will leave the firmware action.
576
577 Note that after the CONFIRM command is sent, the servo will automatically perform a RESET.
578
579 ====== __33. UPDATE & CONFIRM__ ======
580
581 Ex: #5UPDATE<cr>
582
583 This command sets in motion the equivalent of a long button press when the servo is not powered in order to enter firmware update mode. This is useful should the button be broken or inaccessible. The servo then waits for the CONFIRM command. Any other command received will cause the servo to exit the UPDATE function.
584
585 EX: #5UPDATE<cr> followed by #5CONFIRM<cr>
586
587 Since it it not common to have to update firmware, a confirmation command is needed after an UPDATE command is sent. Should any command other than CONFIRM be received by the servo after the firmware command has been received, it will leave the firmware action.
588
589 Note that after the CONFIRM command is sent, the servo will automatically perform a RESET.
590
591 ====== __A1. Angular Stiffness (**AS**)__ ======
592
593 The servo's rigidity / angular stiffness can be thought of as (though not identical to) a damped spring in which the value affects the stiffness and embodies how much, and how quickly the servo tried keep the requested position against changes.
594
595 A positive value of "angular stiffness":
596
597 * The more torque will be applied to try to keep the desired position against external input / changes
598 * The faster the motor will reach its intended travel speed and the motor will decelerate faster and nearer to its target position
599
600 A negative value on the other hand:
601
602 * Causes a slower acceleration to the travel speed, and a slower deceleration
603 * Allows the target position to deviate more from its position before additional torque is applied to bring it back
604
605 The default value is zero and the effect becomes extreme by -4, +4. There are no units, only integers between -4 to 4. Greater values produce increasingly erratic behavior.
606
607 Ex: #5AS-2<cr>
608
609 This reduces the angular stiffness to -2 for that session, allowing the servo to deviate more around the desired position. This can be beneficial in many situations such as impacts (legged robots) where more of a "spring" effect is desired. Upon reset, the servo will use the value stored in memory, based on the last configuration command.
610
611 Ex: #5QAS<cr>
612
613 Queries the value being used.
614
615 Ex: #5CAS<cr>
616
617 Writes the desired angular stiffness value to memory.
618
619 ====== __A2. Angular Holding Stiffness (**AH**)__ ======
620
621 The angular holding stiffness determines the servo's ability to hold a desired position under load. Values can be from -10 to 10, with the default being 0. Note that negative values mean the final position can be easily deflected.
622
623 Ex: #5AH3<cr>
624
625 This sets the holding stiffness for servo #5 to 3 for that session.
626
627 Query Angular Hold Stiffness (**QAH**)
628
629 Ex: #5QAH<cr> might return *5QAH3<cr>
630
631 This returns the servo's angular holding stiffness value.
632
633 Configure Angular Hold Stiffness (**CAH**)
634
635 Ex: #5CAH2<cr>
636
637 This writes the angular holding stiffness of servo #5 to 2 to EEPROM
638
639 ====== __A3: Angular Acceleration (**AA**)__ ======
640
641 {More details to come}
642
643 ====== __A4: Angular Deceleration (**AD**)__ ======
644
645 {More details to come}
646
647 ====== __A5: Motion Control (**EM**)__ ======
648
649 {More details to come}
650
651 ====== __A6. Configure LED Blinking (**CLB**)__ ======
652
653 This command allows you to control when the RGB LED will blink the user set color (see [[16. RGB LED>>||anchor="H16.RGBLED28LED29"]] for details).
654 You can turn on or off blinking for various LSS status. Here is the list and their associated value: 0=No blinking, ; 63=Always blink; Blink while: 1=Limp; 2=Holding 4=Accel; 8=Decel; 16=Free 32=Travel;
655
656 To set blinking, use CLB with the value of your choosing. To activate blinking in multiple status, simply add together the values of the corresponding status. See examples below:
657
658 Ex: #5CLB0<cr> to turn off all blinking (LED always solid)
659 Ex: #5CLB1<cr> only blink when limp
660 Ex: #5CLB2<cr> only blink when holding
661 Ex: #5CLB12<cr> only blink when accel or decel
662 Ex: #5CLB48<cr> only blink when free or travel
663 Ex: #5CLB63<cr> blink in all status
Copyright RobotShop 2018