Wiki source code of LSS-P - Communication Protocol

Version 60.1 by Coleman Benson on 2023/07/27 14:47

Show last authors
1 {{warningBox warningText="More information coming soon"/}}
2
3
4
5 (% class="wikigeneratedid" id="HTableofContents" %)
6 **Page Contents**
7
8 {{toc depth="3"/}}
9
10 = Serial Protocol =
11
12 The Lynxmotion Smart Servo (LSS) PRO serial protocol was created in order to be as simple and straightforward as possible from a user perspective ("human readable format"), while at the same time staying compact and robust yet highly versatile. The protocol was based on Lynxmotion's Smart Servo (LSS) protocol, which itself was based on the SSC-32 & SSC-32U RC servo controllers. The LSS PRO series and normal LSS share many of the same commands, but because of higher angular precision, slightly different operation and different features, the two protocols do not fully overlap.
13
14 In order to be able to control each servo individually with commands, the first step should be to assign a different ID number to each servo (see details on the Configure ID, or "CID" command [[here>>doc:||anchor="HIdentificationNumber28ID29"]]). Only the servo(s) which have been configured to a specific ID will act on a command sent to that ID. There is currently no CRC or checksum implemented as part of the protocol.
15
16 = Action Commands =
17
18 Action commands tell the servo, within that session, to do something (i.e. "take an action"). The types of action commands which can be sent are described below, and they cannot be combined with other commands such as queries or configurations. Only one action command can be sent at a time. Action commands are session-specific, therefore once a servo is power cycled, it will not have any "memory" of previous actions or [[virtual positions>>||anchor="HVirtualAngularPosition"]] (described below). Action commands are sent serially to the servo and must be sent in the following format:
19
20 1. Start with a number sign **#** (Unicode Character: U+0023)
21 1. Servo ID number as an integer (assigning an ID described below)
22 1. Action command (one or more letters, no whitespace, capital or lowercase from the list below)
23 1. Action value in the correct units with no decimal
24 1. End with a carriage return **\r** or **<cr>** Unicode Character (U+000D)
25
26 (((
27 Ex: #5D130000<cr>
28
29 This sends a serial command to all servo's RX pins which are connected to the bus and only servo(s) with ID #5 will move to a position (13000 in hundredths of degrees) of 130.00 degrees. Any servo on the bus which does not have ID 5 will take no action when receiving this command.
30
31 == Modifiers ==
32
33 Modifiers can only be used with certain **action commands**. The format to include a modifier is:
34
35 1. Start with a number sign **#** (Unicode Character: U+0023)
36 1. Servo ID number as an integer
37 1. Action command (one to three letters, no spaces, capital or lowercase from a subset of action commands below)
38 1. Action value in the correct units with no decimal
39 1. Modifier command (one or two letters from the list of modifiers below)
40 1. Modifier value in the correct units with no decimal
41 1. End with a carriage return **\r** or **<cr>** Unicode Character (U+000D)
42
43 Ex: #5D13000T1500<cr>This results in the servo with ID #5 rotating to a position (1800 in tenths of degrees) of 130.00 degrees in a time ("T") of 1500 milliseconds (1.5 seconds).
44
45 == Queries ==
46
47 Query commands request information from the servo. Query commands are also similar to action and configuration commands and must use the following format:
48
49 1. Start with a number sign **#** (Unicode Character: U+0023)
50 1. Servo ID number as an integer
51 1. Query command (one to four letters, no spaces, capital or lower case)
52 1. End with a carriage return **\r** or **<cr>** Unicode Character (U+000D)
53
54 Ex: #5QD<cr> Query the position in (hundredths of) degrees for servo with ID #5The query will return a serial string (almost instantaneously) via the servo's Tx in the following format:
55
56 1. Start with an asterisk * (Unicode Character: U+0023)
57 1. Servo ID number as an integer
58 1. Query command (one to four letters, no spaces, capital letters)
59 1. The reported value in the units described, no decimals.
60 1. End with a carriage return **\r** or **<cr>** Unicode Character (U+000D)
61
62 There is currently no option to control how fast a servo replies after it has received a query command, therefore when sending a query command to the bus, the controller should be prepared to immediately "listen" for and parse the reply. Sending multiple queries to multiple servos on a bus in fast succession may result in replies overlapping and giving incorrect or corrupt data. As such, the controller should receive a reply before sending a new query command. A reply to the query sent above might be:
63
64 Ex: *5QD13000<cr>
65
66 This indicates that servo #5 is currently at 130.00 degrees (13000 tenths of degrees).
67
68 == Configurations ==
69
70 Configuration commands and corresponding values affect a servo's defaults which are written to and read from the servo's EEPROM. These configurations are retained in memory after the servo is reset or power is cut / lost. Some configuration commands affect the session, while others do not. In the Command table below, the column "Session" denotes if the configuration command affects the session. Not all action commands have a corresponding configuration command and vice versa. Configuration commands are not cumulative; this means that if two of the same configuration commands are sent, one after the next, only the last configuration is used and stored.
71
72 The format to send a configuration command is identical to that of an action command:
73
74 1. Start with a number sign **#** (Unicode Character: U+0023)
75 1. Servo ID number as an integer
76 1. Configuration command (two to four letters, no spaces, capital or lower case)
77 1. Configuration value in the correct units with no decimal
78 1. End with a carriage return **\r** or **<cr>** Unicode Character (U+000D)
79
80 Ex: #5CO-500<cr>
81
82 This configures an absolute origin offset ("CO") with respect to factory origin of servo with ID #5 and changes the offset for that session to -5.00 degrees (500 hundredths of degrees). Once the servo is powered off and on, zeroing the servo will cause it to move to -5.00 degrees with respect to the factory origin and report its position as 0 degrees. Configuration commands can be undone / reset either by sending the servo's default value for that configuration, or by doing a factory reset that clears all configurations (through the button menu or with DEFAULT command described below).
83
84 **Session vs Configuration Query**
85
86 By default, the query command returns the session's value. Should no action commands have been sent to change the session value, it will return the value saved in EEPROM which will either be the servo's default, or modified with a configuration command. In order to query the value stored in EEPROM (configuration), add a '1' to the query command:
87
88 Ex: #5CSR10<cr> immediately sets the maximum speed for servo #5 to 10rpm (explained below) and changes the value in memory.
89
90 After RESET, a command of #5SR4<cr> sets the session's speed to 4rpm, but does not change the configuration value in memory. Therefore:
91
92 #5QSR<cr> or #5QSR0<cr> would return *5QSR4<cr> which represents the value for that session, whereas
93
94 #5QSR1<cr> would return *5QSR10<cr> which represents the value in EEPROM
95
96 The ability to store a "virtual angular position" is a feature which allows for rotation beyond 360 degrees, permitting multiple rotations of the output horn, moving the center position and more. The "absolute position" would be the angle of the output shaft with respect to a 360.00 degree circle and can be obtained by taking the modulus (with respect to 360 degrees) of the value. For example if the virtual position is reported as 153350 (or 1533.50 degrees), taking the modulus would give 93.5 degrees (36000 * 4 + 9350 = 153350) as the absolute position (assuming no origin offset).
97
98 [[image:https://wiki.lynxmotion.com/info/wiki/lynxmotion/download/lynxmotion-smart-servo-pro/lss-p-communication-protocol/WebHome/LSS-servo-positions.jpg||alt="LSS-servo-positions.jpg"]]
99
100 In this example, the gyre direction (explained below, a.k.a. "rotation direction") is positive (clockwise), and origin offset has not been modified. Each square represents 30 degrees. The following command is sent:
101
102 #1D-3000<cr> This causes the servo to move to -30.00 degrees (green arrow)
103
104 #1D21000<cr> This second position command is sent to the servo, which moves it to 210.00 degrees (orange arrow)
105
106 #1D-42000<cr> This next command rotates the servo counterclockwise to a position of -420.00 degrees (red arrow), which means one full rotation of 360 degrees plus 60.00 degrees (420.00 - 360.00), with a virtual position of -420.0 degrees.
107
108 Although the final physical position would be the same as if the servo were commanded to move to -60.00 degrees, the servo is in fact at -420.00 degrees.
109
110 #1D48000<cr> This new command is sent which would then cause the servo to rotate from -420.00 degrees to 480.00 degrees (blue arrow), which would be a total of 900 degrees of clockwise rotation, or 2.5 complete rotations.
111
112 #1D33000<cr> would cause the servo to rotate from 480.0 degrees to 330.00 degrees (yellow arrow).
113
114 If the servo loses power or is power cycled, it also loses the virtual position associated with that session. For example, if the virtual position was 480.00 degrees before power is cycled, upon power up the servo's position will be read as +120.00 degrees from zero (assuming center position has not been modified). The virtual position range at power-up is [-180.00°, 180.00°].
115 )))
116
117 = Command List =
118
119 **Latest firmware version currently : v0.0.780**
120
121 |(% colspan="8" style="color:orange; font-size:18px" %)[[**Communication Setup**>>||anchor="HCommunicationSetup"]]
122 |(% style="width:25px" %) |(% style="width:200px" %)**Description**|(% style="text-align:center; width:100px" %)**Action**|(% style="text-align:center; width:75px" %)**Query**|(% style="text-align:center; width:75px" %)**Config**|(% style="width:100px" %)**Default**|(% style="width:170px" %)**Unit**|**Notes**
123 | |[[**Reset**>>||anchor="HReset"]]|(% style="text-align:center" %)RESET|(% style="text-align:center" %) |(% style="text-align:center" %) | | |Soft reset. See command for details.
124 | |[[**Default** Configuration>>||anchor="HDefault26confirm"]]|(% style="text-align:center" %)DEFAULT|(% style="text-align:center" %) |(% style="text-align:center" %) | | |Revert to firmware default values. See command for details
125 | |[[Firmware **Update** Mode>>||anchor="HUpdate26confirm"]]|(% style="text-align:center" %)UPDATE|(% style="text-align:center" %) |(% style="text-align:center" %) | | |Update firmware. See command for details.
126 | |[[**Confirm** Changes>>||anchor="HConfirm"]]|(% style="text-align:center" %)CONFIRM|(% style="text-align:center" %) |(% style="text-align:center" %) | | |
127 | |[[**ID** Number >>||anchor="HIDNumber28ID29"]]|(% style="text-align:center" %) |(% style="text-align:center" %)QID|(% style="text-align:center" %)CID|0| |Reset required after change. ID 254 is a "broadcast" which all servos respond to.
128 | |[[**E**nable CAN **T**erminal>>doc:||anchor="HEnableCANTerminalResistor28ET29"]]|(% style="text-align:center" %) |(% style="text-align:center" %)QET|(% style="text-align:center" %)CET| |0 or 1|0: Disable  1: Enable
129 | |[[**U**SB **C**onnection Status>>||anchor="HUSBConnectionStatus28UC29"]]|(% style="text-align:center" %) |(% style="text-align:center" %)QUC|(% style="text-align:center" %) | |0 or 1|0: Not connected 1: Connected
130 | |[[**Q**uery **F**irmware **R**elease>>doc:||anchor="HFirmwareRelease28FR29"]]|(% style="text-align:center" %) |(% style="text-align:center" %)QFR|(% style="text-align:center" %) | | |
131
132 |(% colspan="8" style="color:orange; font-size:18px" %)[[**Motion**>>||anchor="HMotion"]]
133 |(% style="width:25px" %) |(% style="width:200px" %)**Description**|(% style="text-align:center; width:100px" %)**Action**|(% style="text-align:center; width:75px" %)**Query**|(% style="text-align:center; width:75px" %)**Config**|(% style="width:100px" %)**Default**|(% style="width:170px" %)**Unit**|**Notes**
134 | |[[Position in **D**egrees>>||anchor="HPositioninDegrees28D29"]]|(% style="text-align:center" %)D|(% style="text-align:center" %)QD/QDT|(% style="text-align:center" %) | |1/100°|
135 | |[[**M**ove in **D**egrees (relative)>>||anchor="H28Relative29MoveinDegrees28MD29"]]|(% style="text-align:center" %)MD|(% style="text-align:center" %) |(% style="text-align:center" %) | |1/100°|
136 | |[[**W**heel mode in **D**egrees>>||anchor="HWheelModeinDegrees28WD29"]]|(% style="text-align:center" %)WD|(% style="text-align:center" %)QWD/QVT|(% style="text-align:center" %) | |°/s|A.K.A. "Speed mode" or "Continuous rotation"
137 | |[[**W**heel mode in **R**PM>>||anchor="HWheelModeinRPM28WR29"]]|(% style="text-align:center" %)WR|(% style="text-align:center" %)QWR|(% style="text-align:center" %) | |RPM|A.K.A. "Speed mode" or "Continuous rotation"
138 | |[[**Q**uery Motion Status>>||anchor="HQueryStatus28Q29"]]|(% style="text-align:center" %) |(% style="text-align:center" %)Q|(% style="text-align:center" %) | |1 to 8 integer|See command description for details
139 | |[[**L**imp>>||anchor="HLimp28L29"]]|(% style="text-align:center" %)L|(% style="text-align:center" %) |(% style="text-align:center" %) | | |Removes power from stepper coils
140 | |[[**H**alt & Hold>>||anchor="HHalt26Hold28H29"]]|(% style="text-align:center" %)H|(% style="text-align:center" %) |(% style="text-align:center" %) | | |Stops (halts) motion profile and holds last position
141
142 |(% colspan="8" style="color:orange; font-size:18px" %)[[**Motion Setup**>>||anchor="HMotionSetup"]]
143 |(% style="width:25px" %) |(% style="width:200px" %)**Description**|(% style="text-align:center; width:100px" %)**Action**|(% style="text-align:center; width:75px" %)**Query**|(% style="text-align:center; width:75px" %)**Config**|(% style="width:100px" %)**Default**|(% style="width:170px" %)**Unit**|**Notes**
144 | |[[**O**rigin Offset>>||anchor="HOriginOffset28O29"]]|(% style="text-align:center" %)O|(% style="text-align:center" %)QO|(% style="text-align:center" %)CO|0|1/10°|
145 | |[[**A**ngular **R**ange>>||anchor="HAngularRange28AR29"]]|(% style="text-align:center" %)AR|(% style="text-align:center" %)QAR|(% style="text-align:center" %)CAR|1800|1/10°|
146 | |[[**A**ngular **A**cceleration>>||anchor="HAngularAcceleration28AA29"]]|(% style="text-align:center" %)AA|(% style="text-align:center" %)QAA|(% style="text-align:center" %)CAA|100|°/s^^2^^|Increments of 10°/s^^2^^. Only when motion profile is enabled (EM1).
147 | |[[**A**ngular **D**eceleration>>||anchor="HAngularDeceleration28AD29"]]|(% style="text-align:center" %)AD|(% style="text-align:center" %)QAD|(% style="text-align:center" %)CAD|100|°/s^^2^^|Increments of 10°/s^^2^^. Only when motion profile is enabled (EM1).
148 | |[[**G**yre Direction>>||anchor="HGyreDirection28G29"]]|(% style="text-align:center" %)G|(% style="text-align:center" %)QG|(% style="text-align:center" %)CG|1| |Gyre / rotation direction: 1= CW (clockwise) -1 = CCW (counter-clockwise)
149 | |[[**F**irst Position (**D**eg)>>||anchor="HFirstPosition"]]|(% style="text-align:center" %) |(% style="text-align:center" %)QFD|(% style="text-align:center" %)CFD|No value|1/10°|Reset required after change.
150 | |[[Maximum **S**peed in **D**egrees>>||anchor="HMaximumSpeedinDegrees28SD29"]]|(% style="text-align:center" %)SD|(% style="text-align:center" %)QSD|(% style="text-align:center" %)CSD|Max|0.1°/s|SD overwrites SR / CSD overwrites CSR and vice-versa
151 | |[[Maximum **S**peed in **R**PM>>||anchor="HMaximumSpeedinRPM28SR29"]]|(% style="text-align:center" %)SR|(% style="text-align:center" %)QSR|(% style="text-align:center" %)CSR|Max|RPM|SD overwrites SR / CSD overwrites CSR and vice-versa
152 | |[[Step Mode>>doc:||anchor="HStepMode28SM29"]]|(% style="text-align:center" %)SM|(% style="text-align:center" %)QM|(% style="text-align:center" %)CSM|2|1, 2, 4|Numbers represent fractions: full step, &frac12; step, &frac14; step
153
154 |(% colspan="8" style="color:orange; font-size:18px" %)[[**Modifiers**>>||anchor="HModifiers"]]
155 |(% style="width:25px" %) |(% style="width:200px" %)**Description**|(% style="text-align:center; width:100px" %)**Modifier**|(% style="text-align:center; width:75px" %)**Query**|(% style="text-align:center; width:75px" %)**Config**|(% style="width:100px" %)**Default**|(% style="width:170px" %)**Unit**|**Notes**
156 | |[[**S**peed in **D**egrees>>||anchor="HSpeed28S2CSD29modifier"]]|(% style="text-align:center" %)SD|(% style="text-align:center" %) |(% style="text-align:center" %) | |1°/s|For D and MD action commands
157 | |[[**T**imed move>>||anchor="HTimedmove28T29modifier"]]|(% style="text-align:center" %)T|(% style="text-align:center" %) |(% style="text-align:center" %) | |ms|Time associated with D, MD commands
158
159 |(% colspan="8" style="color:orange; font-size:18px" %)[[**Telemetry**>>||anchor="HTelemetry"]]
160 |(% style="width:25px" %) |(% style="width:200px" %)**Description**|(% style="text-align:center; width:100px" %)**Action**|(% style="text-align:center; width:75px" %)**Query**|(% style="text-align:center; width:75px" %)**Config**|(% style="width:100px" %)**Default**|(% style="width:170px" %)**Unit**|**Notes**
161 | |[[**Q**uery PCB **T**emperature>>||anchor="HQueryTemperature28QT29"]]|(% style="text-align:center" %) |(% style="text-align:center" %)QT|(% style="text-align:center" %) | |°C|
162 | |[[**Q**uery **C**urrent>>||anchor="HQueryCurrent28QC29"]]|(% style="text-align:center" %) |(% style="text-align:center" %)QC|(% style="text-align:center" %) | |mA|Nominal RMS value to stepper motor driver IC.
163 | |[[**Q**uery **M**odel **S**tring>>||anchor="HQueryModelString28QMS29"]]|(% style="text-align:center" %) |(% style="text-align:center" %)QMS|(% style="text-align:center" %) | | |Returns the model of servo (ex: LSS-ST1, LSS-HS1, LSS-HT1)
164 | |[[**Q**uery **F**irmware Version>>||anchor="HQueryFirmware28QF29"]]|(% style="text-align:center" %) |(% style="text-align:center" %)QF|(% style="text-align:center" %) | | |
165 | |[[**Q**uery Serial **N**umber>>||anchor="HQuerySerialNumber28QN29"]]|(% style="text-align:center" %) |(% style="text-align:center" %)QN|(% style="text-align:center" %) | | |Returns the unique serial number for the servo
166 | |[[**Q**uery **T**emperature **P**robe>>doc:||anchor="HQueryTemperatureProbe28QTP29"]]|(% style="text-align:center" %) |(% style="text-align:center" %)QTP|(% style="text-align:center" %) | | |Queries temperature probe fixed to the stepper motor
167 | |[[**Q**uery **T**emp of **M**CU>>doc:||anchor="HQueryMCUTemperature28QTM29"]]|(% style="text-align:center" %) |(% style="text-align:center" %)QTM|(% style="text-align:center" %) | | |
168 | |[[**Q**uery **T**emp of **C**ontroller>>doc:||anchor="HQueryTempofController28QTCW29"]]|(% style="text-align:center" %) |(% style="text-align:center" %)QTCW, QTCE|(% style="text-align:center" %) | | |(((
169 QTCW: Queries the temperature status of the motor controller (pre-warning)
170
171 QTCE: Queries the temperature status of the motor controller (over-temp error)
172 )))
173 | |[[**Q**uery **I**MU Linear **X**>>doc:||anchor="HQueryIMULinear28QIXQIYQIZ29"]]|(% style="text-align:center" %) |(% style="text-align:center" %)QIX|(% style="text-align:center" %) | |mm/s^2|
174 | |[[**Q**uery **I**MU Linear **Y**>>doc:||anchor="HQueryIMULinear28QIXQIYQIZ29"]]|(% style="text-align:center" %) |(% style="text-align:center" %)QIY|(% style="text-align:center" %) | |mm/s^2|
175 | |[[**Q**uery **I**MU Linear **Z**>>doc:||anchor="HQueryIMULinear28QIXQIYQIZ29"]]|(% style="text-align:center" %) |(% style="text-align:center" %)QIZ|(% style="text-align:center" %) | |mm/s^2|
176 | |[[**Q**uery **I**MU Angular Accel **α** >>doc:||anchor="HQueryIMUAngular28QIAQIBQIC29"]]|(% style="text-align:center" %) |(% style="text-align:center" %)QIA|(% style="text-align:center" %) | |°/s^2|Query IMU Angular Accel α (Alpha)
177 | |[[**Q**uery **I**MU Angular Accel **β**>>doc:||anchor="HQueryIMUAngular28QIAQIBQIC29"]]|(% style="text-align:center" %) |(% style="text-align:center" %)QIB|(% style="text-align:center" %) | |°/s^2|Query IMU Angular Accel β (Beta)
178 | |[[**Q**uery **I**MU Angular Accel **γ**>>doc:||anchor="HQueryIMUAngular28QIAQIBQIC29"]]|(% style="text-align:center" %) |(% style="text-align:center" %)QIC / QIG|(% style="text-align:center" %) | |°/s^2|Query IMU Angular Accel γ (Gamma)
179
180 |(% colspan="8" style="color:orange; font-size:18px" %)[[**RGB LED**>>||anchor="HRGBLED"]]
181 |(% style="width:25px" %) |(% style="width:200px" %)**Description**|(% style="text-align:center; width:100px" %)**Action**|(% style="text-align:center; width:75px" %)**Query**|(% style="text-align:center; width:75px" %)**Config**|(% style="width:100px" %)**Default**|(% style="width:170px" %)**Unit**|**Notes**
182 | |[[**LED** Color>>||anchor="HLEDColor28LED29"]]|(% style="text-align:center" %)LED|(% style="text-align:center" %)QLED|(% style="text-align:center" %)CLED| |0 to 7 integer|0=Off; 1=Red; 2=Green; 3=Blue; 4=Yellow; 5=Cyan; 6=Magenta; 7=White
183
184 = (% style="color:inherit; font-family:inherit" %)Details(%%) =
185
186 == (% style="color:inherit; font-family:inherit" %)Communication Setup(%%) ==
187
188 |(% colspan="2" %)(((
189 ====== __Reset__ ======
190 )))
191 | |(((
192 Ex: #5RESET<cr>
193
194 This command does a "soft reset" and reverts all commands to those stored in EEPROM (i.e. configuration commands). Note: after a RESET command is received, the LSS will restart and perform initilization again, making it unavailable on the bus for a bit. See Session, note #2 for more details.
195 )))
196
197 |(% colspan="2" %)(((
198 ====== (% style="color:inherit; font-family:inherit" %)__Default & confirm__(%%) ======
199 )))
200 |(% style="width:30px" %) |(((
201 (% style="color:inherit; font-family:inherit" %)Ex: #5DEFAULT<cr>
202
203 (% style="color:inherit; font-family:inherit" %)This command sets in motion the reset of all values to the default values included with the version of the firmware installed on that servo. The servo then waits for the CONFIRM command. Any other command received will cause the servo to exit the DEFAULT function.
204
205 (% style="color:inherit; font-family:inherit" %)EX: #5DEFAULT<cr> followed by #5CONFIRM<cr>
206
207 (% style="color:inherit; font-family:inherit" %)Since it it not common to have to restore all configurations, a confirmation command is needed after a firmware command is sent. Should any command other than CONFIRM be received by the servo after the firmware command has been received, it will exit the command.
208
209 (% style="color:inherit; font-family:inherit" %)Note: After the CONFIRM command is sent, the servo will automatically perform a RESET.
210 )))
211
212 |(% colspan="2" %)(((
213 ====== (% style="color:inherit; font-family:inherit" %)__Update & confirm__(%%) ======
214 )))
215 |(% style="width:30px" %) |(((
216 (% style="color:inherit; font-family:inherit" %)Ex: #5UPDATE<cr>
217
218 (% style="color:inherit; font-family:inherit" %)This command sets in motion the equivalent of a long button press when the servo is not powered in order to enter firmware update mode. This is useful should the button be broken or inaccessible. The servo then waits for the CONFIRM command. Any other command received will cause the servo to exit the UPDATE function.
219
220 (% style="color:inherit; font-family:inherit" %)EX: #5UPDATE<cr> followed by #5CONFIRM<cr>
221
222 (% style="color:inherit; font-family:inherit" %)Since it it not common to have to update firmware, a confirmation command is needed after an UPDATE command is sent. Should any command other than CONFIRM be received by the servo after the firmware command has been received, it will leave the firmware action.
223
224 (% style="color:inherit; font-family:inherit" %)Note: After the CONFIRM command is sent, the servo will automatically perform a RESET.
225 )))
226
227 |(% colspan="2" %)(((
228 ====== (% style="color:inherit; font-family:inherit" %)__Confirm__(%%) ======
229 )))
230 |(% style="width:30px" %) |(((
231 (% style="color:inherit; font-family:inherit" %)Ex: #5CONFIRM<cr>
232
233 (% style="color:inherit; font-family:inherit" %)This command is used to confirm changes after a Default or Update command.
234 Note: After the CONFIRM command is sent, the servo will automatically perform a RESET.
235 )))
236
237 |(% colspan="2" %)(((
238 ====== (% style="color:inherit; font-family:inherit" %)__ID Number (**ID**)__(%%) ======
239 )))
240 |(% style="width:30px" %) |(((
241 (% style="color:inherit; font-family:inherit" %)Configure ID Number (**CID**)
242
243 (% style="color:inherit; font-family:inherit" %)Ex: #0CID5<cr>
244
245 The default ID is 0, so this sets the servo to ID 5.
246
247 Query ID Number (**QID**)
248
249 Ex: #254QID<cr> might return *254QID5<cr>
250
251 In this case, the broadcast ID is used to ensure the servo connected will reply with the ID. This can be used in case the ID assigned to a servo is forgotten.
252 )))
253
254 |(% colspan="2" %)(((
255 ====== (% style="color:inherit; font-family:inherit" %)__Enable CAN Terminal Resistor (**ET**)__(%%) ======
256 )))
257 |(% style="width:30px" %) |(((
258 Query Enable CAN Terminal Resistor (**QET**)
259
260 Ex: #5QET<cr> might return *QET0<cr>
261
262 This means that servo with ID 5 is NOT configured as the last servo in the CAN bus.
263
264 Configure Enable CAN Terminal Resistor (**CET**)
265
266 (% style="color:inherit; font-family:inherit" %)Ex: #5CET1<cr>
267
268 (% style="color:inherit; font-family:inherit" %)This commands sets servo with ID 5 as being the last in the CAN Bus. The last servo in a CAN bus must be configured this way.
269 )))
270
271 |(% colspan="2" %)(((
272 ====== __USB Connection Status (**UC**)__ ======
273 )))
274 |(% style="width:30px" %) |(((
275 Query USB Connection Status (**QUC**)
276
277 Ex: #5QUC<cr> might return *5QUC1<cr> meaning the servo is connected via USB
278 )))
279
280 |(% colspan="2" %)(((
281 ====== __Firmware Release (**FR**)__ ======
282 )))
283 |(% style="width:30px" %) |(((
284 Query Firmware Release (**QFR**)
285
286 Ex: #5QFR<cr> might return *QFR11<cr> meaning it has a (random) firmware release version number 11.
287
288 This is used to verify if the firmware on the servos is up to date, or which version is running on the microcontroller.
289 )))
290
291 == Motion ==
292
293 ====== __Position in Degrees (**D**)__ ======
294
295 Example: #5D1456<cr>
296
297 This moves the servo to an angle of 145.6 degrees, where the center (0) position is centered. Negative values (ex. -176 representing -17.6 degrees) could also be used. A full circle would be from -1800 to 1800 degrees. A value of 2700 would be the same angle (absolute position) as -900, except the servo would move in a different direction.
298
299 Larger values are permitted and allow for multi-turn functionality using the concept of virtual position (explained above).
300
301 Query Position in Degrees (**QD**)
302
303 Example: #5QD<cr> might return *5QD132<cr>
304
305 This means the servo is located at 13.2 degrees.
306
307 Query Target Position in Degrees (**QDT**)
308
309 Ex: #5QDT<cr> might return *5QDT6783<cr>
310
311 The query target position command returns the target virtual position during and after an action which results in a rotation of the servo horn. In the example above, the servo is rotating to a virtual position of 678.3 degrees. Should the servo not have a target position or be in wheel mode, it will respond with the last target position used.
312
313 ====== __(Relative) Move in Degrees (**MD**)__ ======
314
315
316 Example: #5MD123<cr>
317
318 The relative move command causes the servo to read its current position and move the specified number of tenths of degrees in the corresponding position. For example if the servo is set to rotate CW (default) and an MD command of 123 is sent to the servo, it will cause the servo to rotate clockwise by 12.3 degrees. Negative commands would cause the servo to rotate in the opposite configured direction.
319
320 ====== __Wheel Mode in Degrees (**WD**)__ ======
321
322 Ex: #5WD90<cr>
323
324 This command sets the servo to wheel mode where it will rotate in the desired direction at the selected speed. The example above would have the servo rotate at 90.0 degrees per second clockwise (assuming factory default configurations).
325
326 Query Wheel Mode in Degrees (**QWD**)
327
328 Ex: #5QWD<cr> might return *5QWD90<cr>
329
330 The servo replies with the angular speed in degrees per second. A negative sign would indicate the opposite direction (for factory default a negative value would be counter clockwise).
331
332 ====== __Wheel Mode in RPM (**WR**)__ ======
333
334 Ex: #5WR40<cr>
335
336 This command sets the servo to wheel mode where it will rotate in the desired direction at the selected rpm. Wheel mode (a.k.a. "continuous rotation") has the servo operate like a geared DC motor. The servo's maximum rpm cannot be set higher than its physical limit at a given voltage. The example above would have the servo rotate at 40 rpm clockwise (assuming factory default configurations).
337
338 Query Wheel Mode in RPM (**QWR**)
339
340 Ex: #5QWR<cr> might return *5QWR40<cr>
341
342 The servo replies with the angular speed in rpm. A negative sign would indicate the opposite direction (for factory default a negative value would be counter clockwise).
343
344 ====== __(Relative) Move in Degrees (**MD**)__ ======
345
346 (% class="wikigeneratedid" id="HExample:235M15003Ccr3E" %)
347 Example: #5M1500<cr>
348
349 (% class="wikigeneratedid" id="HTherelativemoveinPWMcommandcausestheservotoreaditscurrentpositionandmovebythespecifiednumberofPWMsignal.ForexampleiftheservoissettorotateCW28default29andanMcommandof1500issenttotheservo2Citwillcausetheservotorotateclockwiseby90degrees.NegativePWMvaluewouldcausetheservotorotateintheoppositeconfigureddirection." %)
350 The relative move in PWM command causes the servo to read its current position and move by the specified number of PWM signal. For example if the servo is set to rotate CW (default) and an M command of 1500 is sent to the servo, it will cause the servo to rotate clockwise by 90 degrees. Negative PWM value would cause the servo to rotate in the opposite configured direction.
351
352 ====== __Query Status (**Q**)__ ======
353
354 The status query describes what the servo is currently doing. The query returns an integer which must be looked up in the table below.
355
356 Ex: #5Q<cr> might return *5Q6<cr>, which indicates the motor is holding a position.
357
358 |(% style="width:25px" %) |***Value returned (Q)**|**Status**|**Detailed description**
359 | |ex: *5Q0<cr>|0: Unknown|LSS is unsure / unknown state
360 | |ex: *5Q1<cr>|1: Limp|Motor driving circuit is not powered and horn can be moved freely
361 | |ex: *5Q2<cr>|2: Free moving|Servo is rotating in duty motion / free move using the RDM command
362 | |ex: *5Q3<cr>|3: Accelerating|Increasing speed from rest (or previous speed) towards travel speed
363 | |ex: *5Q4<cr>|4: Traveling|Moving at a stable speed
364 | |ex: *5Q5<cr>|5: Decelerating|Decreasing from travel speed towards final position.
365 | |ex: *5Q6<cr>|6: Holding|Keeping current position (in EM0 mode, return will nornally be holding)
366 | |ex: *5Q7<cr>|7: Outside limits|{More details coming soon}
367 | |ex: *5Q8<cr>|8: Stuck|Motor cannot perform request movement at current speed setting
368 | |ex: *5Q9<cr>|9: Blocked|Similar to stuck, but the motor is at maximum duty and still cannot move (i.e.: stalled)
369 | |ex: *5Q10<cr>|10: Safe Mode|(((
370 A safety limit has been exceeded (temperature, peak current or extended high current draw).
371
372 Send a Q1 command to know which limit has been reached (described below).
373 )))
374
375 If a safety limit has been reached and exceeded, the LED will flash red and the servo will stop providing torque (no longer react to commands which cause the motor to rotate). In order to determine which limit has been reached, send a Q1 command. The servo must be RESET in order to return to normal operation, though if a limit is still detected (for example the servo is still too hot), it will revert back to Safe Mode.
376
377 |(% style="width:25px" %) |***Value returned (Q1)**|**Status**|**Detailed description**
378 | |ex: *5Q0<cr>|No limits have been passed|Nothing is wrong
379 | |ex: *5Q1<cr>|Current limit has been passed|Something cause the current to either spike, or remain too high for too long
380 | |ex: *5Q2<cr>|Input voltage detected is below or above acceptable range|Check the voltage of your batteries or power source
381 | |ex: *5Q3<cr>|Temperature limit has been reached|The servo is too hot to continue operating safely.
382
383 ====== __Limp (**L**)__ ======
384
385 Example: #5L<cr>
386
387 This action causes the servo to go "limp". The microcontroller will still be powered, but the motor will not. As an emergency safety feature, should the robot not be doing what it is supposed to or risks damage, use the broadcast ID to set all servos limp #254L<cr>.
388
389 ====== __Halt & Hold (**H**)__ ======
390
391 Example: #5H<cr>
392
393 This command causes the servo to stop immediately and hold that angular position. It overrides whatever the servo might be doing at the time the command is received (accelerating, travelling, deccelerating, etc.)
394
395 == Motion Setup ==
396
397 ====== __Origin Offset (**O**)__ ======
398
399 Example: #5O2400<cr>This command allows you to change the origin of the servo in relation to the factory zero position for that session. As with all action commands, the setting will be lost upon servo reset / power cycle. Origin offset commands are not cumulative and always relate to factory zero. In the first image, the origin at factory offset '0' (centered).
400
401 [[image:https://wiki.lynxmotion.com/info/wiki/lynxmotion/download/lynxmotion-smart-servo-pro/lss-p-communication-protocol/WebHome/LSS-servo-default.jpg||alt="LSS-servo-default.jpg"]]
402
403
404 In the second image, the origin, and the corresponding angular range (explained below) have been shifted by +240.0 degrees:
405
406 [[image:https://wiki.lynxmotion.com/info/wiki/lynxmotion/download/lynxmotion-smart-servo-pro/lss-p-communication-protocol/WebHome/LSS-servo-origin.jpg||alt="LSS-servo-origin.jpg"]]
407
408
409 Origin Offset Query (**QO**)
410
411 Example: #5QO<cr> might return *5QO-13
412
413 This allows you to query the angle (in tenths of degrees) of the origin in relation to the factory zero position. In this example, the new origin is at -1.3 degrees from the factory zero.
414
415 Configure Origin Offset (**CO**)
416
417 Example: #5CO-24<cr>
418
419 This command allows you to change the origin of the servo in relation to the factory zero position in EEPROM. The setting will be saved upon servo reset / power cycle. Origin offset configuration commands are not cumulative and always relate to factory zero. The new origin is also used in RC mode. In the example, the new origin will be at -2.4 degrees from the factory zero.
420
421 ====== __Angular Range (**AR**)__ ======
422
423 Example: #5AR1800<cr>
424
425 This command allows you to temporarily change the total angular range of the servo in tenths of degrees. This applies to the Position in Pulse (P) command and RC mode. The default for (P) and RC mode is 1800 (180.0 degrees total, or ±90.0 degrees). The image below shows a standard -180.0 to +180.0 range, with no offset:
426
427 [[image:https://wiki.lynxmotion.com/info/wiki/lynxmotion/download/lynxmotion-smart-servo-pro/lss-p-communication-protocol/WebHome/LSS-servo-default.jpg||alt="LSS-servo-default.jpg"]]
428
429 Below, the angular range is restricted to 180.0 degrees, or -90.0 to +90.0. The center has remained unchanged.
430
431 [[image:https://wiki.lynxmotion.com/info/wiki/lynxmotion/download/lynxmotion-smart-servo-pro/lss-p-communication-protocol/WebHome/LSS-servo-ar.jpg||alt="LSS-servo-ar.jpg"]]
432
433
434 Finally, the angular range action command (ex. #5AR1800<cr>) and origin offset action command (ex. #5O-1200<cr>) are used to move both the center and limit the angular range:
435
436 [[image:https://wiki.lynxmotion.com/info/wiki/lynxmotion/download/lynxmotion-smart-servo-pro/lss-p-communication-protocol/WebHome/LSS-servo-ar-o-1.jpg||alt="LSS-servo-ar-o-1.jpg"]]
437
438
439 Query Angular Range (**QAR**)
440
441 Example: #5QAR<cr> might return *5AR1800, indicating the total angular range is 180.0 degrees.
442
443 Configure Angular Range (**CAR**)
444
445 This command allows you to change the total angular range of the servo in tenths of degrees in EEPROM. The setting will be saved upon servo reset / power cycle.
446
447 ====== __Angular Acceleration (**AA**)__ ======
448
449 The default value for angular acceleration is 100. Accepts values of between 1 and 100. Increments of 10 degrees per second squared.
450
451 Ex: #5AA30<cr>
452
453 This sets the angular acceleration for servo #5 to 30 degrees per second squared (°/s^^2^^).
454
455 Query Angular Acceleration (**QAA**)
456
457 Ex: #5QAA<cr> might return *5QAA30<cr>
458
459 This returns the servo's angular acceleration in degrees per second squared (°/s^^2^^).
460
461 Configure Angular Acceleration (**CAA**)
462
463 Ex: #5CAA30<cr>
464
465 This writes the angular acceleration of servo #5 to 30 degrees per second squared (°/s^^2^^) to EEPROM.
466
467 ====== __Angular Deceleration (**AD**)__ ======
468
469 The default value for angular deceleration is 100. Accepts values of between 1 and 100. Increments of 10 degrees per second squared.
470
471 Ex: #5AD30<cr>
472
473 This sets the angular deceleration for servo #5 to 30 degrees per second squared (°/s^^2^^).
474
475 Query Angular Deceleration (**QAD**)
476
477 Ex: #5QAD<cr> might return *5QAD30<cr>
478
479 This returns the servo's angular deceleration in degrees per second squared (°/s^^2^^).
480
481 Configure Angular Deceleration (**CAD**)
482
483 Ex: #5CAD30<cr>
484
485 This writes the angular deceleration of servo #5 to 30 degrees per second squared (°/s^^2^^) to EEPROM.
486
487 ====== __Gyre Direction (**G**)__ ======
488
489 "Gyre" is defined as a circular course or motion. The effect of changing the gyre direction is as if you were to use a mirror image of a circle. By default: CW = 1; CCW = -1.
490
491 Ex: #5G-1<cr>
492
493 This command will cause servo #5's positions to be inverted, effectively causing the servo to rotate in the opposite direction given the same command. For example in a 2WD robot, servos are often physically installed back to back, therefore setting one of the servos to a negative gyration, the same wheel command (ex WR30) to both servos will cause the robot to move forward or backward rather than rotate.
494
495 Query Gyre Direction (**QG**)
496
497 Ex: #5QG<cr> might return *5QG-1<cr>
498
499 The value returned above means the servo is in a counter-clockwise gyration. Sending a #5WR30 command will rotate the servo in a counter-clockwise gyration at 30 RPM.
500
501 Configure Gyre (**CG**)
502
503 Ex: #5CG-1<cr>
504
505 This changes the gyre direction as described above and also writes to EEPROM.
506
507 ====== __First Position__ ======
508
509 In certain cases, a user might want to have the servo move to a specific angle upon power up; we refer to this as "first position" (a.k.a. "initial position"). The factory default has no first position value stored in EEPROM and therefore upon power up, the servo remains limp until a position (or hold command) is assigned. Note that the number should be restricted to -1790 (-179.0 degrees) to +1790 (179.0 degrees) and values beyond this will be changed to 1800.Query First Position in Degrees (**QFD**)Ex: #5QFD<cr> might return *5QFD900<cr>The reply above indicates that servo with ID 5 has a first position of 90.0 degrees. If there is no first position value stored, the reply will be DIS.Configure First Position in Degrees (**CFD**)Ex: #5CFD900<cr>This configuration command means the servo, when set to smart mode, will immediately move to 90.0 degrees upon power up. Sending a CFD command without a number (Ex. #5CFD<cr>) results in the servo remaining limp upon power up. In order to remove the first position, send no value, ex: #5CFD<cr>
510
511 ====== __Maximum Speed in Degrees (**SD**)__ ======
512
513 Ex: #5SD1800<cr>This command sets the servo's maximum speed for motion commands in tenths of degrees per second for that session. In the example above, the servo's maximum speed for that session would be set to 180.0 degrees per second. The servo's maximum speed cannot be set higher than its physical limit at a given voltage. The SD action command overrides CSD (described below) for that session. Upon reset or power cycle, the servo reverts to the value associated with CSD as described below. Note that SD and SR (described below) are effectively the same, but allow the user to specify the speed in either unit. The last command (either SR or SD) received is what the servo uses for that session.Query Speed in Degrees (**QSD**)Ex: #5QSD<cr> might return *5QSD1800<cr>By default QSD will return the current session value, which is set to the value of CSD as reset/power cycle and changed whenever an SD/SR command is processed. If #5QSD1<cr> is sent, the configured maximum speed (CSD value) will be returned instead. You can also query the current speed using "2" and the current target travel speed using "3". See the table below for an example:
514
515 |**Command sent**|**Returned value (1/10 °)**
516 |ex: #5QSD<cr>|Session value for maximum speed (set by latest SD/SR command)
517 |ex: #5QSD1<cr>|Configured maximum speed in EEPROM (set by CSD/CSR)
518 |ex: #5QSD2<cr>|Instantaneous speed (same as QWD)
519 |ex: #5QSD3<cr>|Target travel speed
520
521 Configure Speed in Degrees (**CSD**)Ex: #5CSD1800<cr>Using the CSD command sets the servo's maximum speed which is saved in EEPROM. In the example above, the servo's maximum speed will be set to 180.0 degrees per second. When the servo is powered on (or after a reset), the CSD value is used. Note that CSD and CSR (described below) are effectively the same, but allow the user to specify the speed in either unit. The last command (either CSR or CSD) is what the servo uses for that session.
522
523 ====== __Maximum Speed in RPM (**SR**)__ ======
524
525 Ex: #5SR45<cr>This command sets the servo's maximum speed for motion commands in rpm for that session. In the example above, the servo's maximum speed for that session would be set to 45rpm. The servo's maximum speed cannot be set higher than its physical limit at a given voltage. SR overrides CSR (described below) for that session. Upon reset or power cycle, the servo reverts to the value associated with CSR as described below. Note that SD (described above) and SR are effectively the same, but allow the user to specify the speed in either unit. The last command (either SR or SD) received is what the servo uses for that session.Query Speed in RPM (**QSR**)Ex: #5QSR<cr> might return *5QSR45<cr>By default QSR will return the current session value, which is set to the value of CSR as reset/power cycle and changed whenever an SD/SR command is processed. If #5QSR1<cr> is sent, the configured maximum speed (CSR value) will be returned instead. You can also query the current speed using "2" and the current target travel speed using "3". See the table below for an example:
526
527 |**Command sent**|**Returned value (1/10 °)**
528 |ex: #5QSR<cr>|Session value for maximum speed (set by latest SD/SR command)
529 |ex: #5QSR1<cr>|Configured maximum speed in EEPROM (set by CSD/CSR)
530 |ex: #5QSR2<cr>|Instantaneous speed (same as QWD)
531 |ex: #5QSR3<cr>|Target travel speed
532
533 Configure Speed in RPM (**CSR**)Ex: #5CSR45<cr>Using the CSR command sets the servo's maximum speed which is saved in EEPROM. In the example above, the servo's maximum speed will be set to 45rpm. When the servo is powered on (or after a reset), the CSR value is used. Note that CSD and CSR are effectively the same, but allow the user to specify the speed in either unit. The last command (either CSR or CSD) received is what the servo uses for that session.
534
535 ====== __Step Mode (**SM**)__ ======
536
537 Ex: #8SM2<cr>
538
539 This sets servo with ID 8 to 1/2 step mode. Since this is an action as opposed to a configuration, it only affects that session.
540
541 Note that the torque and max RPM of the actuator will be affected.
542
543 Query Step Mode (**QSM**)
544
545 Ex: #8QSM<cr> might return *8QSM2<cr> meaning servo with ID 8 is set to half step mode.
546
547 Configure Step Mode (**CSM**)
548
549 Ex: #8SM2<cr>
550
551 This sets servo with ID 8 to 1/2 step mode. Since this is a configuration as opposed to a configuration and the servo will be in 1/2 step mode when powered.
552
553 == Modifiers ==
554
555 ====== __Speed (**SD**) modifier__ ======
556
557 (% class="wikigeneratedid" id="HTimedmove28T29modifier" %)
558 Example: #5D0SD180<cr>
559
560 (% class="wikigeneratedid" %)
561 Modifier (SD) is only for a position (D) or relative position (MD) action and determines the speed of the move in tenths of degrees per second. A speed modifier (SD) of 180 would cause the servo to rotate from its current position to the desired absolute or relative position at a speed of 18 degrees per second.
562
563 (% class="wikigeneratedid" %)
564 Query Speed (**QS**)
565
566 (% class="wikigeneratedid" %)
567 Example: #5QS<cr> might return *5QS300<cr>
568
569 (% class="wikigeneratedid" %)
570 This command queries the current speed in microseconds per second.
571
572 ====== __Timed move (**T**) modifier__ ======
573
574 Example: #5D15000T2500<cr>
575
576 Timed move can be used only as a modifier for a position (D, MD) actions. The units are in milliseconds, so a timed move of 2500 milliseconds would cause the servo to rotate from its current position to the desired position in 2.5 seconds. The onboard controller will attempt to ensure that the move is performed entirely at the desired velocity, though differences in torque may cause it to not be exact. This command is in place to ensure backwards compatibility with the SSC-32 / 32U protocol.
577
578 **Note:** If the calculated speed at which a servo must rotate for a timed move is greater than its maximum speed (which depends on voltage and load), then it will move at its maximum speed, and the time of the move may be longer than requested
579
580 ====== ======
581
582 == Telemetry ==
583
584 ====== __Query PCB Temperature (**QT**)__ ======
585
586 Ex: #5QT<cr> might return *5QT564<cr>
587
588 The units are in tenths of degrees Celcius, so in the example above, the servo's internal temperature is 56.4 degrees C. To convert from degrees Celcius to degrees Farenheit, multiply by 1.8 and add 32. Therefore 56.4C = 133.52F.
589
590 ====== __Query Temperature Probe (**QTP**)__ ======
591
592 Ex:
593
594 ====== __Query Temp of Controller (**QTCW**)__ ======
595
596 Ex:
597
598 An alternative is QTCE
599
600 ====== __Query Current (**QC**)__ ======
601
602 Ex: #5QC<cr> might return *5QC140<cr>
603
604 The units are in milliamps, so in the example above, the servo is consuming 140mA, or 0.14A. It represents the RMS value. The query calculates the RMS value of the current sent from the motor driver to the stepper motor.
605
606 ====== __Query Model String (**QMS**)__ ======
607
608 Ex: #5QMS<cr> might return *5QMSLSS-HS1<cr>
609
610 This reply means that the servo model is LSS-HS1: a high speed servo, first revision.
611
612 ====== __Query Firmware (**QF**)__ ======
613
614 Ex: #5QF<cr> might return *5QF368<cr>
615
616 The number in the reply represents the firmware version, in this example being 368.The command #5QF3<cr> can also be sent and the servo will reply with a 3 numbers firmware version, for example, 368.29.14
617
618 ====== __Query Serial Number (**QN**)__ ======
619
620 Ex: #5QN<cr> might return *5QN12345678<cr>
621
622 The number in the response (12345678) would be the servo's serial number which is set and should not be changed by the user.
623
624 ====== __Query IMU Linear (**QIX** **QIY** **QIZ**)__ ======
625
626 Ex: #6QIX<cr> might return *6QIX30<cr>
627
628 This command queries servo 6's IMU's linear accelerometer in the X direction. The response is 30mm per second squared.
629
630 ====== __Query IMU Angular (**QIA** **QIB** **QIC**)__ ======
631
632 Ex: #6QIB<cr> might return *6QIB44<cr>
633
634 This command queries servo 6's IMU's linear accelerometer in the X direction. The response is 4.4 degrees per second squared.
635
636
Copyright RobotShop 2018