Last modified by Eric Nantel on 2025/06/06 07:47

From version < 93.1 >
edited by Coleman Benson
on 2019/01/31 15:51
To version < 172.1 >
edited by Eric Nantel
on 2020/05/01 09:24
< >
Change comment: Rollback to version 170.1

Summary

Details

Page properties
Parent
... ... @@ -1,1 +1,1 @@
1 -Lynxmotion Smart Servo (LSS).WebHome
1 +lynxmotion-smart-servo.WebHome
Author
... ... @@ -1,1 +1,1 @@
1 -xwiki:XWiki.CBenson
1 +xwiki:XWiki.ENantel
Content
... ... @@ -1,655 +1,958 @@
1 1  (% class="wikigeneratedid" id="HTableofContents" %)
2 -**Table of Contents**
2 +**Page Contents**
3 3  
4 4  {{toc depth="3"/}}
5 5  
6 -= Serial Protocol Concept =
6 += Serial Protocol =
7 7  
8 -The Lynxmotion Smart Servo (LSS) serial protocol was created in order to be as simple and straightforward as possible from a user perspective ("human readable"), while at the same time trying to be compact and robust yet highly versatile. The protocol was based on Lynxmotion's SSC-32 RC servo controller and almost everything one might expect to be able to configure for a smart servo motor is available.
8 +The Lynxmotion Smart Servo (LSS) serial protocol was created in order to be as simple and straightforward as possible from a user perspective ("human readable format"), while at the same time staying compact and robust yet highly versatile. The protocol was based on Lynxmotion's SSC-32 & SSC-32U RC servo controllers and almost everything one might expect to be able to configure for a smart servomotor is available.
9 9  
10 -In serial mode, in order to have servos react differently when commands are sent to all servos in a bus, the first step a user should take is to assign a different ID number to each servo (explained below). Once this has been done, only the servo(s) which have been assigned to the ID sent as part of the command will take action. There is currently no CRC / checksum implemented as part of the protocol.
10 +In order to be able to control each servo individually with commands, the first step should be to assign a different ID number to each servo (see details on CID [[here>>doc:||anchor="HIdentificationNumber28ID29"]]). Once this has been done, only the servo(s) which have been assigned to the ID sent as part of the command will follow that command. There is currently no CRC or checksum implemented as part of the protocol.
11 11  
12 12  == Session ==
13 13  
14 -A "session" is defined as the time between when the servo is powered ON to when it is powered OFF or reset.
14 +{{html wiki="true" clean="false"}}
15 +<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
16 +A "session" is defined as the time between when the servo is powered ON to when it is powered OFF or reset.<div class="wikimodel-emptyline"></div>
15 15  
18 +**Note #1:** For a given session, the action related to a specific commands overrides the stored value in EEPROM.<div class="wikimodel-emptyline"></div>
19 +**Note #2:** During the power-on / reset process the LSS cannot accept commands for a small amount of time (1.25 s).<div class="wikimodel-emptyline"></div>
20 +You can ensure the LSS is ready by using a query command to check for response (ex: #[id]Q\r or #[id]QID\r). If the LSS is ready for commands (initialized) it will respond to the query. A timeout between 50-100 ms is recommended to compensate for drivers, OS and buffering delays.
21 +<div class="wikimodel-emptyline"></div></div></div>
22 +{{/html}}
23 +
16 16  == Action Commands ==
17 17  
18 -Action commands tell the servo, within that session, to do something (i.e. "take an action"). The type of action commands which can be sent are described below, and they cannot be combined with other commands such as queries or configurations. Only one action command can be sent at a time. Action commands are session-specific, therefore once a servo is power cycled, it will not have any "memory" of previous actions or virtual positions (as described at the bottom of this page). Action commands are sent serially to the servo's Rx pin and must be set in the following format:
26 +{{html wiki="true" clean="false"}}
27 +<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
28 +Action commands tell the servo, within that session, to do something (i.e. "take an action"). The types of action commands which can be sent are described below, and they cannot be combined with other commands such as queries or configurations. Only one action command can be sent at a time. Action commands are session-specific, therefore once a servo is power cycled, it will not have any "memory" of previous actions or [[virtual positions>>||anchor="HVirtualAngularPosition"]]. Action commands are sent serially to the servo's Rx pin and must be sent in the following format:<div class="wikimodel-emptyline"></div>
19 19  
20 -1. Start with a number sign # (U+0023)
30 +1. Start with a number sign **#** (Unicode Character: U+0023)
21 21  1. Servo ID number as an integer
22 -1. Action command (one to three letters, no spaces, capital or lower case)
32 +1. Action command (one or more letters, no whitespace, capital or lower case)
23 23  1. Action value in the correct units with no decimal
24 -1. End with a control / carriage return '<cr>'
34 +1. End with a carriage return **&#92;r** or **&lt;cr&gt;** Unicode Character (U+000D)
25 25  
26 26  (((
27 -Ex: #5PD1443<cr>
37 +Ex: #5D1800&lt;cr&gt;<div class="wikimodel-emptyline"></div>
28 28  
29 -This sends a serial command to all servo's Rx pins which are connected to the bus and only servo(s) with ID #5 will move to a position of 144.3 degrees. Any servo in the bus which does not have ID 5 will take no action when they receive this command.
39 +This sends a serial command to all servo's RX pins which are connected to the bus and only servo(s) with ID #5 will move to a position (1800 in tenths of degrees) of 180.0 degrees. Any servo on the bus which does not have ID 5 will take no action when receiving this command.
40 +<div class="wikimodel-emptyline"></div></div></div>
41 +{{/html}}
30 30  
31 -== Action Modifiers ==
43 +== Modifiers ==
32 32  
33 -Only two commands can be used as action modifiers: Timed Move (T) and Speed (S). Action modifiers can only be used with certain action commands. The format to include a modifier is:
45 +{{html wiki="true" clean="false"}}
46 +<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
47 +Modifiers can only be used with certain **action commands**. The format to include a modifier is:<div class="wikimodel-emptyline"></div>
34 34  
35 -1. Start with a number sign # (U+0023)
49 +1. Start with a number sign **#** (Unicode Character: U+0023)
36 36  1. Servo ID number as an integer
37 37  1. Action command (one to three letters, no spaces, capital or lower case)
38 38  1. Action value in the correct units with no decimal
39 -1. Modifier command (one letter)
53 +1. Modifier command (one letter to too letters)
40 40  1. Modifier value in the correct units with no decimal
41 -1. End with a control / carriage return '<cr>'
55 +1. End with a carriage return **&#92;r** or **&lt;cr&gt;** Unicode Character (U+000D)
42 42  
43 -Ex: #5P1456T1263<cr>
57 +Ex: #5D1800T1500&lt;cr&gt;<div class="wikimodel-emptyline"></div>
44 44  
45 -This results in the servo with ID #5 rotating from the current angular position to a pulse position of 1456 in 1263 milliseconds. Position in pulses is described below.
46 -)))
59 +This results in the servo with ID #5 rotating to a position (1800 in tenths of degrees) of 180.0 degrees in a time ("T") of 1500 milliseconds (1.5 seconds).<div class="wikimodel-emptyline"></div>
60 +<div class="wikimodel-emptyline"></div></div></div>
61 +{{/html}}
47 47  
48 -== Configuration Commands ==
63 +== Query Commands ==
49 49  
50 -Configuration commands affect a servo's default values which are written to the servo's EEPROM and are retained in memory after the servo loses power or is reset. Some configuration commands affect the session, while others do not (see each command for details). Not all action commands have a corresponding configuration and vice versa. More information about which configuration commands are retained in RC mode can be found on the [[LSS - RC PWM page>>doc:Lynxmotion Smart Servo (LSS).LSS - RC PWM.WebHome]]. Configuration commands are not cumulative, in that if two configurations are sent, one after the next, only the last configuration is used and stored. The format to send a configuration command is identical to that of an action command:
65 +{{html wiki="true" clean="false"}}
66 +<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
67 +Query commands request information from the servo. They are received via the Rx pin of the servo, and the servo's reply is sent via the servo's Tx pin. Using separate lines for Tx and Rx is called "full duplex". Query commands are also similar to action and configuration commands and must use the following format:<div class="wikimodel-emptyline"></div>
51 51  
52 -1. Start with a number sign # (U+0023)
69 +1. Start with a number sign **#** (Unicode Character: U+0023)
53 53  1. Servo ID number as an integer
54 -1. Configuration command (two to three letters, no spaces, capital or lower case)
55 -1. Configuration value in the correct units with no decimal
56 -1. End with a control / carriage return '<cr>'
71 +1. Query command (one to four letters, no spaces, capital or lower case)
72 +1. End with a carriage return **&#92;r** or **&lt;cr&gt;** Unicode Character (U+000D)<div class="wikimodel-emptyline"></div>
57 57  
58 -Ex: #5CO-50<cr>
74 +Ex: #5QD&lt;cr&gt; Query position in (tenth of) degrees for servo #5<div class="wikimodel-emptyline"></div>
59 59  
60 -This assigns an absolute origin offset of -5.0 degrees (with respect to factory origin) to servo with ID #5 and changes the offset for that session to -5.0 degrees. Once the servo is powered off and then powered on, zeroing the servo will cause it to move to -5.0 degrees with respect to the factory origin. Configuration commands can be undone / reset either by sending the servo's default value for that configuration, or by doing a factory reset (clears all configurations) described below.
76 +The query will return a serial string (almost instantaneously) via the servo's Tx pin with the following format:
61 61  
62 -== Query Commands ==
78 +1. Start with an asterisk * (Unicode Character: U+0023)
79 +1. Servo ID number as an integer
80 +1. Query command (one to four letters, no spaces, capital letters)
81 +1. The reported value in the units described, no decimals.
82 +1. End with a carriage return **&#92;r** or **&lt;cr&gt;** Unicode Character (U+000D)<div class="wikimodel-emptyline"></div>
63 63  
64 -Query commands request information from the servo. They are received via the Rx pin of the servo, and the servo's reply is sent via the servo's Tx pin. This is called "full duplex". Query commands are also similar to action and configuration commands and must use the following format:
84 +There is currently no option to control how fast a servo replies after it has received a query command, therefore when sending a query command to the bus, the controller should be prepared to immediately "listen" for and parse the reply. Sending multiple queries to multiple servos on a bus in fast succession may result in replies overlapping and giving incorrect or corrupt data. As such, the controller should receive a reply before sending a new query command. A reply to the query sent above might be:<div class="wikimodel-emptyline"></div>
65 65  
66 -1. Start with a number sign # (U+0023)
67 -1. Servo ID number as an integer
68 -1. Query command (one to three letters, no spaces, capital or lower case)
69 -1. End with a control / carriage return '<cr>'
86 +Ex: *5QD1800&lt;cr&gt;<div class="wikimodel-emptyline"></div>
70 70  
71 -(((
72 -Ex: #5QD<cr>Query position in degrees for servo #5
73 -)))
88 +This indicates that servo #5 is currently at 180.0 degrees (1800 tenths of degrees).
89 +<div class="wikimodel-emptyline"></div></div></div>
90 +{{/html}}
74 74  
75 -(((
76 -The query will return a serial string (almost instantaneously) via the servo's Tx pin with the following format:
92 +== Configuration Commands ==
77 77  
78 -1. Start with an asterisk * (U+002A)
79 -1. Servo ID number as an integer
80 -1. Query command (one to three letters, no spaces, capital letters)
81 -1. The reported value in the units described, no decimals.
82 -1. End with a control / carriage return '<cr>'
94 +{{html wiki="true" clean="false"}}
95 +<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
96 +Configuration commands and corresponding values affect a servo's defaults which are written to and read from the servo's EEPROM.<div class="wikimodel-emptyline"></div>
83 83  
84 -There is currently no option to control how fast a servo replies after it has received a query command, therefore when sending a query command to the bus, the controller should be prepared to immediately "listen" for and parse the reply. Sending multiple queries on a bus in fast succession may result in replies overlapping and giving incorrect or corrupt data. As such, the controller should receive a reply before sending a new command.
98 +These configurations are retained in memory after the servo is reset or power is cut / lost. Some configuration commands affect the session, while others do not. In the Command table below, the column "Session" denotes if the configuration command affects the session. Not all action commands have a corresponding configuration command and vice versa. More information about which configuration commands are retained when in RC mode can be found on the [[LSS - RC PWM page>>doc:lynxmotion-smart-servo.lss-radio-control-pwm.WebHome]]. Configuration commands are not cumulative. This means that if two same configuration commands are sent, one after the next, only the last configuration is used and stored.<div class="wikimodel-emptyline"></div>
85 85  
86 -(((
87 -Ex: *5QD1443<cr>
88 -)))
100 +The format to send a configuration command is identical to that of an action command:<div class="wikimodel-emptyline"></div>
89 89  
90 -This reply to the query above indicates that servo #5 is currently at 144.3 degrees (1443 tenths of degrees).
102 +1. Start with a number sign **#** (Unicode Character: U+0023)
103 +1. Servo ID number as an integer
104 +1. Configuration command (two to four letters, no spaces, capital or lower case)
105 +1. Configuration value in the correct units with no decimal
106 +1. End with a carriage return **&#92;r** or **&lt;cr&gt;** Unicode Character (U+000D)<div class="wikimodel-emptyline"></div>
91 91  
92 -**Session vs Configuration Query**
108 +Ex: #5CO-50&lt;cr&gt;<div class="wikimodel-emptyline"></div>
93 93  
94 -By default, the query command returns the sessions' value. Should no action commands have been sent to change the session value, it will return the value saved in EEPROM from the last configuration command.
110 +This configures an absolute origin offset ("CO") with respect to factory origin of servo with ID #5 and changes the offset for that session to -5.0 degrees (50 tenths of degrees). Once the servo is powered off and on, zeroing the servo will cause it to move to -5.0 degrees with respect to the factory origin and report its position as 0 degrees. Configuration commands can be undone / reset either by sending the servo's default value for that configuration, or by doing a factory reset that clears all configurations (through the button menu or with DEFAULT command described below).<div class="wikimodel-emptyline"></div>
95 95  
96 -In order to query the value in EEPROM (configuration), add a '1' to the query command.
112 +**Session vs Configuration Query**<div class="wikimodel-emptyline"></div>
97 97  
98 -Ex: #5CSR20<cr> immediately sets the maximum speed for servo #5 to 20rpm (explained below) .
114 +By default, the query command returns the session's value. Should no action commands have been sent to change the session value, it will return the value saved in EEPROM which will either be the servo's default, or modified with a configuration command. In order to query the value stored in EEPROM (configuration), add a '1' to the query command:<div class="wikimodel-emptyline"></div>
99 99  
100 -After RESET: #5SR4<cr> sets the session's speed to 4rpm.
116 +Ex: #5CSR20&lt;cr&gt; immediately sets the maximum speed for servo #5 to 20rpm (explained below) and changes the value in memory.<div class="wikimodel-emptyline"></div>
101 101  
102 -#5QSR<cr> would return *5QSR4<cr> which represents the value for that session.
118 +After RESET, a command of #5SR4&lt;cr&gt; sets the session's speed to 4rpm, but does not change the configuration value in memory. Therefore:<div class="wikimodel-emptyline"></div>
103 103  
104 -#5QSR1<cr> would return *5QSR20<cr> which represents the value in EEPROM
120 +#5QSR&lt;cr&gt; or #5QSR0&lt;cr&gt; would return *5QSR4&lt;cr&gt; which represents the value for that session, whereas<div class="wikimodel-emptyline"></div>
105 105  
122 +#5QSR1&lt;cr&gt; would return *5QSR20&lt;cr&gt; which represents the value in EEPROM
123 +<div class="wikimodel-emptyline"></div></div></div>
124 +{{/html}}
125 +
106 106  == Virtual Angular Position ==
107 107  
108 -A "virtual position" is a feature which allows for rotation beyond 360 degrees, permitting multiple rotations of the output horn, moving the center position and more. In virtual position mode, the "absolute position" would be the angle of the output shaft with respect to 360.0 degrees, and can be obtained by taking the modulus (with respect to 360 degrees) of the value. For example if the virtual position is reported as 15335 (or 1533.5 degrees), taking the modulus would give 93.5 degrees (3600 * 4 + 935 = 15335).
128 +{{html wiki="true" clean="false"}}
129 +<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
130 +The ability to store a "virtual angular position" is a feature which allows for rotation beyond 360 degrees, permitting multiple rotations of the output horn, moving the center position and more. The "absolute position" would be the angle of the output shaft with respect to a 360.0 degree circle and can be obtained by taking the modulus (with respect to 360 degrees) of the value. For example if the virtual position is reported as 15335 (or 1533.5 degrees), taking the modulus would give 93.5 degrees (3600 * 4 + 935 = 15335) as the absolute position (assuming no origin offset).<div class="wikimodel-emptyline"></div>
109 109  
110 -[[image:LSS-servo-positions.jpg]]
132 +[[image:LSS-servo-positions.jpg]]<div class="wikimodel-emptyline"></div>
111 111  
112 -In this example, the gyre direction (explained below, a.k.a. rotation direction) is positive (clockwise), and origin offset has not been modified. Each square represents 30 degrees. The following command is sent:
134 +In this example, the gyre direction (explained below, a.k.a. "rotation direction") is positive (clockwise), and origin offset has not been modified. Each square represents 30 degrees. The following command is sent:<div class="wikimodel-emptyline"></div>
113 113  
114 -#1D-300<cr> This causes the servo to move to -30.0 degrees (green arrow)
136 +#1D-300&lt;cr&gt; This causes the servo to move to -30.0 degrees (green arrow)<div class="wikimodel-emptyline"></div>
115 115  
116 -#1D2100<cr> This second position command is sent to the servo, which moves it to 210.0 degrees (orange arrow)
138 +#1D2100&lt;cr&gt; This second position command is sent to the servo, which moves it to 210.0 degrees (orange arrow)<div class="wikimodel-emptyline"></div>
117 117  
118 -#1D-4200<cr> This next command rotates the servo counterclockwise to a position of -420 degrees (red arrow), which means one full rotation of 360 degrees stopping at an absolute position of 60.0 degrees (420.0 - 360.0), with a virtual position of -420.0 degrees.
140 +#1D-4200&lt;cr&gt; This next command rotates the servo counterclockwise to a position of -420 degrees (red arrow), which means one full rotation of 360 degrees plus 60.0 degrees (420.0 - 360.0), with a virtual position of -420.0 degrees.<div class="wikimodel-emptyline"></div>
119 119  
120 -Although the final physical position would be the same as if the servo were commanded to move to -60.0 degrees, the servo is in fact at -420.0 degrees.
142 +Although the final physical position would be the same as if the servo were commanded to move to -60.0 degrees, the servo is in fact at -420.0 degrees.<div class="wikimodel-emptyline"></div>
121 121  
122 -#1D4800<cr> This new command is sent which would then cause the servo to rotate from -420.0 degrees to 480.0 degrees (blue arrow), which would be a total of 900 degrees of clockwise rotation, or 2.5 complete rotations.
144 +#1D4800&lt;cr&gt; This new command is sent which would then cause the servo to rotate from -420.0 degrees to 480.0 degrees (blue arrow), which would be a total of 900 degrees of clockwise rotation, or 2.5 complete rotations.<div class="wikimodel-emptyline"></div>
123 123  
124 -#1D3300<cr> would cause the servo to rotate from 480.0 degrees to 330.0 degrees (yellow arrow).
146 +#1D3300&lt;cr&gt; would cause the servo to rotate from 480.0 degrees to 330.0 degrees (yellow arrow).<div class="wikimodel-emptyline"></div>
125 125  
126 -If / once the servo loses power or is power cycled, it also loses the virtual position associated with that session. For example, if the virtual position was 480.0 degrees before power is cycled, upon power up the servo's position will be read as +120.0 degrees from zero (assuming center position has not been modified).
127 -)))
148 +If the servo loses power or is power cycled, it also loses the virtual position associated with that session. For example, if the virtual position was 480.0 degrees before power is cycled, upon power up the servo's position will be read as +120.0 degrees from zero (assuming center position has not been modified). The virtual position range at power-up is [-180.0°, 180.0°].
149 +<div class="wikimodel-emptyline"></div></div></div>
150 +{{/html}}
128 128  
129 129  = Command List =
130 130  
131 -|= #|=Description|= Action|= Query|= Config|= RC|= Serial|= Units|=(% style="width: 510px;" %) Notes|=(% style="width: 113px;" %)Default Value
132 -| 1|[[**L**imp>>||anchor="H1.Limp28L29"]]| L| | | | ✓|none|(% style="width:510px" %) |(% style="text-align:center; width:113px" %)
133 -| 2|[[**H**alt & **H**old>>||anchor="H2.Halt26Hold28H29"]]| H| | | | ✓|none|(% style="width:510px" %) |(% style="text-align:center; width:113px" %)
134 -| 3|[[**T**imed move>>||anchor="H3.Timedmove28T29"]]| T| | | | ✓|milliseconds|(% style="width:510px" %) Modifier only for {P, D, MD}|(% style="text-align:center; width:113px" %)
135 -| 4|[[**S**peed>>||anchor="H4.Speed28S29"]]| S| | | | ✓|microseconds / second|(% style="width:510px" %) Modifier only {P}|(% style="text-align:center; width:113px" %)
136 -| 5|[[**M**ove in **D**egrees (relative)>>||anchor="H5.28Relative29MoveinDegrees28MD29"]]| MD| | | | ✓|tenths of degrees (ex 325 = 32.5 degrees; 91 = 9.1 degrees)|(% style="width:510px" %) |(% style="text-align:center; width:113px" %)
137 -| 6|[[**O**rigin Offset>>||anchor="H6.OriginOffsetAction28O29"]]| O| QO| CO| ✓| ✓|tenths of degrees (ex 325 = 32.5 degrees; 91 = 9.1 degrees)|(% style="width:510px" %) |(% style="text-align:center; width:113px" %)(((
138 -0
139 -)))
140 -| 7|[[**A**ngular **R**ange>>||anchor="H7.AngularRange28AR29"]]| AR| QAR| CAR| ✓| ✓|tenths of degrees (ex 325 = 32.5 degrees; 91 = 9.1 degrees)|(% style="width:510px" %) |(% style="text-align:center; width:113px" %)(((
141 -1800
142 -)))
143 -| 8|[[Position in **P**ulse>>||anchor="H8.PositioninPulse28P29"]]| P| QP| | | ✓|microseconds|(% style="width:510px" %)(((
144 -Inherited from SSC-32 serial protocol
145 -)))|(% style="text-align:center; width:113px" %)
146 -| 9|[[Position in **D**egrees>>||anchor="H9.PositioninDegrees28D29"]]| D| QD| | | ✓|tenths of degrees (ex 325 = 32.5 degrees; 91 = 9.1 degrees)|(% style="width:510px" %) |(% style="text-align:center; width:113px" %)
147 -| 10|[[**W**heel mode in **D**egrees>>||anchor="H10.WheelModeinDegrees28WD29"]]| WD| QWD| | | ✓|tenths of degrees per second (ex 248 = 24.8 degrees per second)|(% style="width:510px" %)A.K.A. "Speed mode" or "Continuous rotation"|(% style="text-align:center; width:113px" %)
148 -| 11|[[**W**heel mode in **R**PM>>||anchor="H11.WheelModeinRPM28WR29"]]| WR| QWR| | | ✓| rpm|(% style="width:510px" %)A.K.A. "Speed mode" or "Continuous rotation"|(% style="text-align:center; width:113px" %)
149 -| 12|[[Max **S**peed in **D**egrees>>||anchor="H12.SpeedinDegrees28SD29"]]| SD| QSD|CSD| ✓| ✓|tenths of degrees per second (ex 248 = 24.8 degrees per second)|(% style="width:510px" %)QSD: Add modifier "2" for instantaneous speed|(% style="text-align:center; width:113px" %)Max per servo
150 -| 13|[[Max **S**peed in **R**PM>>||anchor="H13.SpeedinRPM28SR29"]]| SR| QSR|CSR| ✓| ✓|rpm|(% style="width:510px" %)QSR: Add modifier "2" for instantaneous speed|(% style="text-align:center; width:113px" %)Max per servo
151 -| 16|[[**LED** Color>>||anchor="H16.RGBLED28LED29"]]| LED| QLED| CLED| ✓| ✓|none (integer from 0 to 8)|(% style="width:510px" %)0=Off (black); 1=Red 2=Green; 3=Blue; 4=Yellow; 5=Cyan; 6=Magenta; 7=White;|(% style="text-align:center; width:113px" %)7
152 -| 17|[[**ID** #>>||anchor="H17.IdentificationNumber"]]| | QID| CID| | ✓|none (integer from 0 to 250)|(% style="width:510px" %)Note: ID 254 is a "broadcast" which all servos respond to|(% style="text-align:center; width:113px" %)0
153 -| 18|[[**B**aud rate>>||anchor="H18.BaudRate"]]| B| QB| CB| | ✓|none (integer)|(% style="width:510px" %) |(% style="text-align:center; width:113px" %)9600
154 -| 19|[[**G**yre direction (**G**)>>||anchor="H19.GyreRotationDirection"]]| G| QG| CG| ✓| ✓|none |(% style="width:510px" %) Gyre / rotation direction where 1= CW (clockwise) -1 = CCW (counter-clockwise)|(% style="text-align:center; width:113px" %)1 CW
155 -| 20|[[**F**irst Position (**P**ulse)>>||anchor="H20.First2InitialPosition28pulse29"]]| | QFP|CFP | ✓| ✓|none |(% style="width:510px" %) |(% style="text-align:center; width:113px" %)(((
156 -Limp
157 -)))
158 -| 21|[[**F**irst Position (**D**egrees)>>||anchor="H21.First2InitialPosition28Degrees29"]]| | QFD|CFD| ✓| ✓|none |(% style="width:510px" %) |(% style="text-align:center; width:113px" %)Limp
159 -| 22|[[**T**arget (**D**egree) **P**osition>>||anchor="H22.QueryTargetPositioninDegrees28QDT29"]]| | QDT| | | ✓|tenths of degrees (ex 325 = 32.5 degrees; 91 = 9.1 degrees)|(% style="width:510px" %) |(% style="text-align:center; width:113px" %)
160 -| 23|[[**M**odel **S**tring>>||anchor="H23.QueryModelString28QMS29"]]| | QMS| | | |none (string)|(% style="width:510px" %) Recommended to determine the model|(% style="text-align:center; width:113px" %)
161 -| 23b|[[**M**odel>>||anchor="H23b.QueryModel28QM29"]]| | QM| | | |none (integer)|(% style="width:510px" %) Returns a raw value representing the three model inputs (36 bit)|(% style="text-align:center; width:113px" %)
162 -| 24|[[Serial **N**umber>>||anchor="H24.QuerySerialNumber28QN29"]]| | QN| | | |none (integer)|(% style="width:510px" %) |(% style="text-align:center; width:113px" %)
163 -| 25|[[**F**irmware version>>||anchor="H25.QueryFirmware28QF29"]]| | QF| | | |none (integer)|(% style="width:510px" %) |(% style="text-align:center; width:113px" %)
164 -| 26|[[**Q**uery (general status)>>||anchor="H26.QueryStatus28Q29"]]| | Q| | | ✓|none (integer from 1 to 8)|(% style="width:510px" %) See command description for details|(% style="text-align:center; width:113px" %)
165 -| 27|[[**V**oltage>>||anchor="H27.QueryVoltage28QV29"]]| | QV| | | ✓|millivolts (ex 5936 = 5936mV = 5.936V)|(% style="width:510px" %) |(% style="text-align:center; width:113px" %)
166 -| 28|[[**T**emperature>>||anchor="H28.QueryTemperature28QT29"]]| | QT| | | ✓|tenths of degrees Celsius|(% style="width:510px" %)Max temp before error: 85°C (servo goes limp)|(% style="text-align:center; width:113px" %)
167 -| 29|[[**C**urrent>>||anchor="H29.QueryCurrent28QC29"]]| | QC| | | ✓|milliamps (ex 200 = 0.2A)|(% style="width:510px" %) |(% style="text-align:center; width:113px" %)
168 -| 30|[[**RC** Mode>>||anchor="H30.RCMode28CRC29"]]| | |CRC| |✓|none|(% style="width:510px" %)(((
169 -CRC: Add modifier "1" for RC-position mode.
170 -CRC: Add modifier "2" for RC-wheel mode.
171 -Any other value for the modifier results in staying in smart mode.
172 -Puts the servo into RC mode. To revert to smart mode, use the button menu.
173 -)))|(% style="text-align:center; width:113px" %)Serial
174 -|31|[[**RESET**>>||anchor="H31.RESET"]]| | | | | ✓|none|(% style="width:510px" %)Soft reset. See command for details.|(% style="text-align:center; width:113px" %)
175 -|32|[[**DEFAULT**>>||anchor="H32.DEFAULTA026CONFIRM"]]| | | | |✓|none|(% style="width:510px" %)Revert to firmware default values. See command for details|(% style="text-align:center; width:113px" %)
176 -|33|[[**UPDATE**>>||anchor="H33.UPDATEA026CONFIRM"]]| | | | |✓|none|(% style="width:510px" %)Update firmware. See command for details.|(% style="text-align:center; width:113px" %)
154 +**Latest firmware version currently : 368.29.14**
177 177  
178 -(% class="wikigeneratedid" %)
179 -== Advanced ==
156 +|(% colspan="10" style="color:orange; font-size:18px" %)**Communication Setup**
157 +|(% style="width:25px" %) |(% style="width:200px" %)**Description**|(% style="text-align:center; width:100px" %)**Action**|(% style="text-align:center; width:75px" %)**Query**|(% style="text-align:center; width:75px" %)**Config**|(% style="text-align:center; width:75px" %)**RC**|(% style="text-align:center; width:75px" %)**Serial**|(% style="width:100px" %)**Default**|(% style="width:170px" %)**Unit**|**Notes**
158 +| |Soft **Reset**|(% style="text-align:center" %)RESET|(% style="text-align:center" %) |(% style="text-align:center" %) |(% style="text-align:center" %) |(% style="text-align:center" %)✓| | |Soft reset. See command for details.
159 +| |**Default** Configuration|(% style="text-align:center" %)DEFAULT|(% style="text-align:center" %) |(% style="text-align:center" %) |(% style="text-align:center" %) |(% style="text-align:center" %)✓| | |Revert to firmware default values. See command for details
160 +| |Firmware **Update** Mode|(% style="text-align:center" %)UPDATE|(% style="text-align:center" %) |(% style="text-align:center" %) |(% style="text-align:center" %) |(% style="text-align:center" %)✓| | |Update firmware. See command for details.
161 +| |**Confirm** Changes|(% style="text-align:center" %)CONFIRM|(% style="text-align:center" %) |(% style="text-align:center" %) |(% style="text-align:center" %) |(% style="text-align:center" %)✓| | |
162 +| |**C**hange to **RC**|(% style="text-align:center" %) |(% style="text-align:center" %) |(% style="text-align:center" %)CRC|(% style="text-align:center" %) |(% style="text-align:center" %)✓| | |Change to RC mode 1 (position) or 2 (wheel).
163 +| |**ID** #|(% style="text-align:center" %) |(% style="text-align:center" %)QID|(% style="text-align:center" %)CID|(% style="text-align:center" %) |(% style="text-align:center" %)✓|0| |Reset required after change. ID 254 is a "broadcast" which all servos respond to.
164 +| |**B**audrate|(% style="text-align:center" %) |(% style="text-align:center" %)QB|(% style="text-align:center" %)CB|(% style="text-align:center" %) |(% style="text-align:center" %)✓|115200| |Reset required after change.
180 180  
181 -|= #|=Description|= Action|= Query|= Config|= RC|= Serial|= Units|=(% style="width: 510px;" %) Notes|=(% style="width: 113px;" %)Default Value
182 -| 1|[[**A**ngular **S**tiffness>>||anchor="H14.AngularStiffness28AS29"]]| AS| QAS|CAS| ✓| ✓|none|(% style="width:510px" %)-4 to +4, but suggested values are between 0 to +4|(% style="text-align:center; width:113px" %)0
183 -| 2|[[**A**ngular **H**olding Stiffness>>||anchor="H15.AngularHoldStiffness28AH29"]]|AH|QAH|CAH| | ✓|none|(% style="width:510px" %)-10 to +10, with default as 0. |(% style="text-align:center; width:113px" %)1
184 -| 3|[[**A**ngular **A**cceleration>>||anchor="H15b:AngularAcceleration28AA29"]]|AA|QAA|CAA| | ✓|degrees per second squared|(% style="width:510px" %)Increments of 10 degrees per second squared|(% style="text-align:center; width:113px" %)
185 -| 4|[[**A**ngular **D**eceleration>>||anchor="H15c:AngularDeceleration28AD29"]]|AD|QAD|CAD| | ✓|degrees per second squared|(% style="width:510px" %)Increments of 10 degrees per second squared|(% style="text-align:center; width:113px" %)
186 -| 5|[[**E**nable **M**otion control>>||anchor="H15d:MotionControl28MC29"]]|EM|QEM| | | ✓|none|(% style="width:510px" %)EM0 to disable motion control, EM1 to enable. Session specific / does not survive power cycles|(% style="text-align:center; width:113px" %)
187 -| 6|[[**C**onfigure **L**ED **B**linking>>||anchor="H16b.ConfigureLEDBlinking28CLB29"]]| | | CLB| ✓| |none (integer from 0 to 63)|(% style="width:510px" %)0=No blinking, ; 63=Always blink; Blink while: 1=Limp; 2=Holding 4=Accel; 8=Decel; 16=Free 32=Travel;|(% style="text-align:center; width:113px" %)
188 -| | | | | | | | |(% style="width:510px" %) |(% style="text-align:center; width:113px" %)
166 +|(% colspan="10" style="color:orange; font-size:18px" %)**Motion**
167 +|(% style="width:25px" %) |(% style="width:200px" %)**Description**|(% style="text-align:center; width:100px" %)**Action**|(% style="text-align:center; width:75px" %)**Query**|(% style="text-align:center; width:75px" %)**Config**|(% style="text-align:center; width:75px" %)**RC**|(% style="text-align:center; width:75px" %)**Serial**|(% style="width:100px" %)**Default**|(% style="width:170px" %)**Unit**|**Notes**
168 +| |Position in **D**egrees|(% style="text-align:center" %)D|(% style="text-align:center" %)QD/QDT|(% style="text-align:center" %) |(% style="text-align:center" %) |(% style="text-align:center" %)✓| |1/10°|
169 +| |**M**ove in **D**egrees (relative)|(% style="text-align:center" %)MD|(% style="text-align:center" %) |(% style="text-align:center" %) |(% style="text-align:center" %) |(% style="text-align:center" %)✓| |1/10°|
170 +| |**W**heel mode in **D**egrees|(% style="text-align:center" %)WD|(% style="text-align:center" %)QWD/QVT|(% style="text-align:center" %) |(% style="text-align:center" %) |(% style="text-align:center" %)✓| |°/s|A.K.A. "Speed mode" or "Continuous rotation"
171 +| |**W**heel mode in **R**PM|(% style="text-align:center" %)WR|(% style="text-align:center" %)QWR|(% style="text-align:center" %) |(% style="text-align:center" %) |(% style="text-align:center" %)✓| |RPM|A.K.A. "Speed mode" or "Continuous rotation"
172 +| |Position in **P**WM|(% style="text-align:center" %)P|(% style="text-align:center" %)QP|(% style="text-align:center" %) |(% style="text-align:center" %) |(% style="text-align:center" %)✓| |us|Inherited from SSC-32 serial protocol
173 +| |**M**ove in PWM (relative)|(% style="text-align:center" %)M|(% style="text-align:center" %) |(% style="text-align:center" %) |(% style="text-align:center" %) |(% style="text-align:center" %)✓| |us|
174 +| |**R**aw **D**uty-cycle **M**ove|(% style="text-align:center" %)RDM|(% style="text-align:center" %)QMD|(% style="text-align:center" %) |(% style="text-align:center" %) |(% style="text-align:center" %)✓| |-1023 to 1023 integer|Positive values : CW / Negative values : CCW
175 +| |**Q**uery Status|(% style="text-align:center" %) |(% style="text-align:center" %)Q|(% style="text-align:center" %) |(% style="text-align:center" %) |(% style="text-align:center" %)✓| |1 to 8 integer|See command description for details
176 +| |**L**imp|(% style="text-align:center" %)L|(% style="text-align:center" %) |(% style="text-align:center" %) |(% style="text-align:center" %) |(% style="text-align:center" %)✓| | |
177 +| |**H**alt & Hold|(% style="text-align:center" %)H|(% style="text-align:center" %) |(% style="text-align:center" %) |(% style="text-align:center" %) |(% style="text-align:center" %)✓| | |
189 189  
190 -== Details ==
179 +|(% colspan="10" style="color:orange; font-size:18px" %)**Motion Setup**
180 +|(% style="width:25px" %) |(% style="width:200px" %)**Description**|(% style="text-align:center; width:100px" %)**Action**|(% style="text-align:center; width:75px" %)**Query**|(% style="text-align:center; width:75px" %)**Config**|(% style="text-align:center; width:75px" %)**RC**|(% style="text-align:center; width:75px" %)**Serial**|(% style="width:100px" %)**Default**|(% style="width:170px" %)**Unit**|**Notes**
181 +| |**E**nable **M**otion Profile|(% style="text-align:center" %)EM|(% style="text-align:center" %)QEM|(% style="text-align:center" %)CEM|(% style="text-align:center" %) |(% style="text-align:center" %)✓|1| |EM1: trapezoidal motion profile / EM0: no motion profile
182 +| |**F**ilter **P**osition **C**ount|(% style="text-align:center" %)FPC|(% style="text-align:center" %)QFPC|(% style="text-align:center" %)CFPC|(% style="text-align:center" %)✓|(% style="text-align:center" %)✓|5| |Affects motion only when motion profile is disabled (EM0)
183 +| |**O**rigin Offset|(% style="text-align:center" %)O|(% style="text-align:center" %)QO|(% style="text-align:center" %)CO|(% style="text-align:center" %)✓|(% style="text-align:center" %)✓|0|1/10°|
184 +| |**A**ngular **R**ange|(% style="text-align:center" %)AR|(% style="text-align:center" %)QAR|(% style="text-align:center" %)CAR|(% style="text-align:center" %)✓|(% style="text-align:center" %)✓|1800|1/10°|
185 +| |**A**ngular **S**tiffness|(% style="text-align:center" %)AS|(% style="text-align:center" %)QAS|(% style="text-align:center" %)CAS|(% style="text-align:center" %)✓|(% style="text-align:center" %)✓|0|-4 to +4 integer|Suggested values are between 0 to +4
186 +| |**A**ngular **H**olding Stiffness |(% style="text-align:center" %)AH|(% style="text-align:center" %)QAH|(% style="text-align:center" %)CAH|(% style="text-align:center" %)✓|(% style="text-align:center" %)✓|4|-10 to +10 integer|
187 +| |**A**ngular **A**cceleration|(% style="text-align:center" %)AA|(% style="text-align:center" %)QAA|(% style="text-align:center" %)CAA|(% style="text-align:center" %) |(% style="text-align:center" %)✓|100|°/s^^2^^|Increments of 10°/s^^2^^. Only when motion profile is enabled (EM1).
188 +| |**A**ngular **D**eceleration|(% style="text-align:center" %)AD|(% style="text-align:center" %)QAD|(% style="text-align:center" %)CAD|(% style="text-align:center" %) |(% style="text-align:center" %)✓|100|°/s^^2^^|Increments of 10°/s^^2^^. Only when motion profile is enabled (EM1).
189 +| |**G**yre Direction|(% style="text-align:center" %)G|(% style="text-align:center" %)QG|(% style="text-align:center" %)CG|(% style="text-align:center" %)✓|(% style="text-align:center" %)✓|1| |Gyre / rotation direction: 1= CW (clockwise) -1 = CCW (counter-clockwise)
190 +| |**F**irst Position (**D**eg)|(% style="text-align:center" %) |(% style="text-align:center" %)QFD|(% style="text-align:center" %)CFD|(% style="text-align:center" %)✓|(% style="text-align:center" %)✓|No value|1/10°|Reset required after change.
191 +| |**M**aximum **M**otor **D**uty|(% style="text-align:center" %)MMD|(% style="text-align:center" %)QMMD|(% style="text-align:center" %) |(% style="text-align:center" %) |(% style="text-align:center" %)✓|1023|255 to 1023 integer|
192 +| |Maximum **S**peed in **D**egrees|(% style="text-align:center" %)SD|(% style="text-align:center" %)QSD|(% style="text-align:center" %)CSD|(% style="text-align:center" %)✓|(% style="text-align:center" %)✓|Max|°/s|SD overwrites SR / CSD overwrites CSR and vice-versa
193 +| |Maximum **S**peed in **R**PM|(% style="text-align:center" %)SR|(% style="text-align:center" %)QSR|(% style="text-align:center" %)CSR|(% style="text-align:center" %)✓|(% style="text-align:center" %)✓|Max|RPM|SD overwrites SR / CSD overwrites CSR and vice-versa
191 191  
192 -====== __1. Limp (**L**)__ ======
195 +|(% colspan="10" style="color:orange; font-size:18px" %)**Modifiers**
196 +|(% style="width:25px" %) |(% style="width:200px" %)**Description**|(% style="text-align:center; width:100px" %)**Modifier**|(% style="text-align:center; width:75px" %)**Query**|(% style="text-align:center; width:75px" %)**Config**|(% style="text-align:center; width:75px" %)**RC**|(% style="text-align:center; width:75px" %)**Serial**|(% style="width:100px" %)**Default**|(% style="width:170px" %)**Unit**|**Notes**
197 +| |**S**peed|(% style="text-align:center" %)S|(% style="text-align:center" %)QS|(% style="text-align:center" %) |(% style="text-align:center" %) |(% style="text-align:center" %)✓| |uS/s |For P action command
198 +| |**S**peed in **D**egrees|(% style="text-align:center" %)SD|(% style="text-align:center" %) |(% style="text-align:center" %) |(% style="text-align:center" %) |(% style="text-align:center" %)✓| |°/s|For D and MD action commands
199 +| |**T**imed move|(% style="text-align:center" %)T|(% style="text-align:center" %) |(% style="text-align:center" %) |(% style="text-align:center" %) |(% style="text-align:center" %)✓| |ms|Modifier only for P, D and MD. Time can change based on load
200 +| |**C**urrent **H**old|(% style="text-align:center" %)CH|(% style="text-align:center" %) |(% style="text-align:center" %) |(% style="text-align:center" %) |(% style="text-align:center" %)✓| |mA|Modifier for D, MD, WD and WR
201 +| |**C**urrent **L**imp|(% style="text-align:center" %)CL|(% style="text-align:center" %) |(% style="text-align:center" %) |(% style="text-align:center" %) |(% style="text-align:center" %)✓| |mA|Modifier for D, MD, WD and WR
193 193  
194 -Example: #5L<cr>
203 +|(% colspan="10" style="color:orange; font-size:18px" %)**Telemetry**
204 +|(% style="width:25px" %) |(% style="width:200px" %)**Description**|(% style="text-align:center; width:100px" %)**Action**|(% style="text-align:center; width:75px" %)**Query**|(% style="text-align:center; width:75px" %)**Config**|(% style="text-align:center; width:75px" %)**RC**|(% style="text-align:center; width:75px" %)**Serial**|(% style="width:100px" %)**Default**|(% style="width:170px" %)**Unit**|**Notes**
205 +| |**Q**uery **V**oltage|(% style="text-align:center" %) |(% style="text-align:center" %)QV|(% style="text-align:center" %) |(% style="text-align:center" %) |(% style="text-align:center" %)✓| |mV|
206 +| |**Q**uery **T**emperature|(% style="text-align:center" %) |(% style="text-align:center" %)QT|(% style="text-align:center" %) |(% style="text-align:center" %) |(% style="text-align:center" %)✓| |1/10°C|
207 +| |**Q**uery **C**urrent|(% style="text-align:center" %) |(% style="text-align:center" %)QC|(% style="text-align:center" %) |(% style="text-align:center" %) |(% style="text-align:center" %)✓| |mA|
208 +| |**Q**uery **M**odel **S**tring|(% style="text-align:center" %) |(% style="text-align:center" %)QMS|(% style="text-align:center" %) |(% style="text-align:center" %) |(% style="text-align:center" %)✓| | |Returns the model of servo (ex: LSS-ST1, LSS-HS1, LSS-HT1)
209 +| |**Q**uery **F**irmware Version|(% style="text-align:center" %) |(% style="text-align:center" %)QF|(% style="text-align:center" %) |(% style="text-align:center" %) |(% style="text-align:center" %)✓| | |
210 +| |**Q**uery Serial **N**umber|(% style="text-align:center" %) |(% style="text-align:center" %)QN|(% style="text-align:center" %) |(% style="text-align:center" %) |(% style="text-align:center" %)✓| | |Returns the unique serial number for the servo
195 195  
196 -This action causes the servo to go "limp". The microcontroller will still be powered, but the motor will not. As an emergency safety feature, should the robot not be doing what it is supposed to or risks damage, use the broadcast ID to set all servos limp #254L<cr>.
212 +|(% colspan="10" style="color:orange; font-size:18px" %)**RGB LED**
213 +|(% style="width:25px" %) |(% style="width:200px" %)**Description**|(% style="text-align:center; width:100px" %)**Action**|(% style="text-align:center; width:75px" %)**Query**|(% style="text-align:center; width:75px" %)**Config**|(% style="text-align:center; width:75px" %)**RC**|(% style="text-align:center; width:75px" %)**Serial**|(% style="width:100px" %)**Default**|(% style="width:170px" %)**Unit**|**Notes**
214 +| |**LED** Color|(% style="text-align:center" %)LED|(% style="text-align:center" %)QLED|(% style="text-align:center" %)CLED|(% style="text-align:center" %)✓|(% style="text-align:center" %)✓| |0 to 7 integer|0=Off; 1=Red; 2=Green; 3=Blue; 4=Yellow; 5=Cyan; 6=Magenta; 7=White
215 +| |**C**onfigure **L**ED **B**linking|(% style="text-align:center" %) |(% style="text-align:center" %)QLB|(% style="text-align:center" %)CLB|(% style="text-align:center" %)✓|(% style="text-align:center" %)✓| |0 to 63 integer|Reset required after change. See command for details.
197 197  
198 -====== __2. Halt & Hold (**H**)__ ======
217 += (% style="color:inherit; font-family:inherit" %)Details(%%) =
199 199  
200 -Example: #5H<cr>
219 +== (% style="color:inherit; font-family:inherit" %)Communication Setup(%%) ==
201 201  
202 -This action overrides whatever the servo might be doing at the time the command is received (accelerating, moving continuously etc.) and causes it to stop immediately and hold that position.
221 +====== __Reset__ ======
203 203  
204 -====== __3. Timed move (**T**)__ ======
223 +{{html wiki="true" clean="false"}}
224 +<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
225 +Ex: #5RESET<cr><div class="wikimodel-emptyline"></div>
226 +This command does a "soft reset" and reverts all commands to those stored in EEPROM (i.e. configuration commands).
227 +Note: after a RESET command is received, the LSS will restart and perform initilization again, making it unavailable on the bus for a bit. See [[Session>>||anchor="HSession"]], note #2 for more details.<div class="wikimodel-emptyline"></div>
228 +</div></div>
229 +{{/html}}
205 205  
206 -Example: #5P1500T2500<cr>
231 +====== __Default & confirm__ ======
207 207  
208 -Timed move can be used only as a modifier for a position (P) action. The units are in milliseconds, so a timed move of 2500 milliseconds would cause the servo to rotate from its current position to the desired position in 2.5 seconds. This command is in place to ensure backwards compatibility with the SSC-32 / 32U protocol.
233 +{{html wiki="true" clean="false"}}
234 +<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
235 +Ex: #5DEFAULT<cr><div class="wikimodel-emptyline"></div>
209 209  
210 -Note: If the calculated speed at which a servo must rotate for a timed move is greater than its maximum speed (which depends on voltage and load), then it will move at its maximum speed, and the time of the move may be longer than requested.
237 +This command sets in motion the reset of all values to the default values included with the version of the firmware installed on that servo. The servo then waits for the CONFIRM command. Any other command received will cause the servo to exit the DEFAULT function.<div class="wikimodel-emptyline"></div>
211 211  
212 -====== __4. Speed (**S**)__ ======
239 +EX: #5DEFAULT<cr> followed by #5CONFIRM<cr><div class="wikimodel-emptyline"></div>
213 213  
214 -Example: #5P1500S750<cr>
241 +Since it it not common to have to restore all configurations, a confirmation command is needed after a firmware command is sent. Should any command other than CONFIRM be received by the servo after the firmware command has been received, it will exit the command.<div class="wikimodel-emptyline"></div>
215 215  
216 -This command is a modifier only for a position (P) action and determines the speed of the move in microseconds per second. A speed of 750 microseconds would cause the servo to rotate from its current position to the desired position at a speed of 750 microseconds per second. This command is in place to ensure backwards compatibility with the SSC-32 / 32U protocol.
243 +**Note:** After the CONFIRM command is sent, the servo will automatically perform a RESET.<div class="wikimodel-emptyline"></div>
244 +</div></div>
245 +{{/html}}
217 217  
218 -====== __5. (Relative) Move in Degrees (**MD**)__ ======
247 +====== __Update & confirm__ ======
219 219  
220 -Example: #5MD123<cr>
249 +{{html wiki="true" clean="false"}}
250 +<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
251 +Ex: #5UPDATE<cr><div class="wikimodel-emptyline"></div>
221 221  
222 -The relative move command causes the servo to read its current position and move the specified number of tenths of degrees in the corresponding position. For example if the servo is set to rotate CW (default) and an MD command of 123 is sent to the servo, it will cause the servo to rotate clockwise by 12.3 degrees. Negative commands would cause the servo to rotate in the opposite configured direction.
253 +This command sets in motion the equivalent of a long button press when the servo is not powered in order to enter firmware update mode. This is useful should the button be broken or inaccessible. The servo then waits for the CONFIRM command. Any other command received will cause the servo to exit the UPDATE function.<div class="wikimodel-emptyline"></div>
223 223  
224 -====== __6. Origin Offset Action (**O**)__ ======
255 +EX: #5UPDATE<cr> followed by #5CONFIRM<cr><div class="wikimodel-emptyline"></div>
225 225  
226 -Example: #5O2400<cr>
257 +Since it it not common to have to update firmware, a confirmation command is needed after an UPDATE command is sent. Should any command other than CONFIRM be received by the servo after the firmware command has been received, it will leave the firmware action.<div class="wikimodel-emptyline"></div>
227 227  
228 -This command allows you to temporarily change the origin of the servo in relation to the factory zero position. The setting will be lost upon servo reset / power cycle. Origin offset commands are not cumulative and always relate to factory zero. Note that for a given session, the O command overrides the CO command. In the first image, the origin at factory offset '0' (centered).
259 +**Note:** After the CONFIRM command is sent, the servo will automatically perform a RESET.<div class="wikimodel-emptyline"></div>
260 +</div></div>
261 +{{/html}}
229 229  
230 -[[image:LSS-servo-default.jpg]]
263 +====== __Configure RC Mode (**CRC**)__ ======
231 231  
232 -In the second image, the origina, as well as the angular range (explained below) have been shifted by 240.0 degrees:
265 +{{html wiki="true" clean="false"}}
266 +<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
267 +This command puts the servo into RC mode (position or continuous), where it will only respond to RC PWM signal on the servo's Rx pin. In this mode, the servo will no longer accept serial commands. The servo can be placed back into smart mode by using the button menu.<div class="wikimodel-emptyline"></div>
233 233  
234 -[[image:LSS-servo-origin.jpg]]
269 +|**Command sent**|**Note**
270 +|ex: #5CRC1<cr>|Change to RC position mode.
271 +|ex: #5CRC2<cr>|Change to RC continuous rotation (wheel) mode.
272 +|ex: #5CRC*<cr>|Where * is any value other than 1 or 2 (or no value): stay in smart mode.<div class="wikimodel-emptyline"></div>
235 235  
236 -Origin Offset Query (**QO**)
274 +EX: #5CRC2<cr><div class="wikimodel-emptyline"></div>
237 237  
238 -Example: #5QO<cr> Returns: *5QO-13
276 +This command would place the servo in RC wheel mode after a RESET or power cycle. Note that after a RESET or power cycle, the servo will be in RC mode and will not reply to serial commands. Using the command #5CRC<cr> or #5CRC3<cr> which requests that the servo remain in serial mode still requires a RESET command.<div class="wikimodel-emptyline"></div>
239 239  
240 -This allows you to query the angle (in tenths of degrees) of the origin in relation to the factory zero position.
278 +**Important note: **To revert from RC mode back to serial mode, the [[LSS - Button Menu>>doc:lynxmotion-smart-servo.lss-button-menu.WebHome]] is required. Should the button be inaccessible (or broken) when the servo is in RC mode and the user needs to change to serial mode, a 5V constant HIGH needs to be sent to the servo's Rx pin (RC PWM pin), **ensuring a common GND** and wait for 30 seconds. Normal RC PWM pulses should not exceed 2500 milliseconds. After 30 seconds, the servo will interpret this as a desired mode change and change to serial mode. This has been implemented as a fail safe.<div class="wikimodel-emptyline"></div>
279 +</div></div>
280 +{{/html}}
241 241  
242 -Configure Origin Offset (**CO**)
282 +====== __Identification Number (**ID**)__ ======
243 243  
244 -Example: #5CO-24<cr>
284 +{{html wiki="true" clean="false"}}
285 +<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
286 +A servo's identification number cannot be set "on the fly" and must be configured via the CID command described below. The factory default ID number for all servos is 0. Since smart servos are intended to be daisy chained, in order to respond differently from one another, the user must set different identification numbers. Servos with the same ID and baud rate will all receive and react to the same commands.<div class="wikimodel-emptyline"></div>
245 245  
246 -This command allows you to change the origin of the servo in relation to the factory zero position in EEPROM. The setting will be saved upon servo reset / power cycle. Origin offset configuration commands are not cumulative and always relate to factory zero. The new origin is also used in RC mode.
288 +Query Identification (**QID**)<div class="wikimodel-emptyline"></div>
247 247  
248 -====== __7. Angular Range (**AR**)__ ======
290 +EX: #254QID<cr> might return *QID5<cr><div class="wikimodel-emptyline"></div>
249 249  
250 -Example: #5AR1800<cr>
292 +When using the broadcast query ID command, it is best to only have one servo connected and thus receive only one reply. This is useful when you are not sure of the servo's ID, but don't want to change it. Using the broadcast command (ID 254) with only one servo will have that servo reply with its ID number. Alternatively, pushing the button upon startup and temporarily setting the servo ID to 255 will still result in the servo responding with its "real" ID.<div class="wikimodel-emptyline"></div>
251 251  
252 -This command allows you to temporarily change the total angular range of the servo in tenths of degrees. This applies to the Position in Pulse (P) command and RC mode. The default for (P) and RC mode is 1800 (180.0 degrees total, or ±90.0 degrees). In the first image,
294 +Configure ID (**CID**)<div class="wikimodel-emptyline"></div>
253 253  
254 -[[image:LSS-servo-default.jpg]]
296 +Ex: #4CID5<cr><div class="wikimodel-emptyline"></div>
255 255  
256 -Here, the angular range has been restricted to 180.0 degrees, or -90.0 to +90.0. The center has remained unchanged.
298 +Setting a servo's ID in EEPROM is done via the CID command. All servos connected to the same serial bus that have will be assigned that ID. In most situations each servo must be set a unique ID, which means each servo must be connected individually to the serial bus and receive a unique CID number. It is best to do this before the servos are added to an assembly. Numbered stickers are provided to distinguish each servo after their ID is set, though you are free to use whatever alternative method you like. The servo must be RESET or power cycled in order for the new ID to take effect.<div class="wikimodel-emptyline"></div>
299 +</div></div>
300 +{{/html}}
257 257  
258 -[[image:LSS-servo-ar.jpg]]
302 +====== __Baud Rate__ ======
259 259  
260 -The angular range action command (ex. #5AR1800<cr>) and origin offset action command (ex. #5O-1200<cr>) an be used to move both the center and limit the angular range:
304 +{{html wiki="true" clean="false"}}
305 +<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
306 +A servo's baud rate cannot be set "on the fly" and must be configured via the CB command described below. The factory default baud rate for all servos is 115200. Since smart servos are intended to be daisy chained, in order to respond to the same serial command, all servos in a project should be set to the same baud rate. Setting different baud rates will have the servos respond differently and may create issues. Available baud rates are: 9600 bps, 19200 bps, 38400 bps, 57600 bps, 115.2 kbps, 230.4 kbps, 250.0 kbps, 460.8 kbps, 500.0 kbps. Servos are shipped with a baud rate set to 115200.<div class="wikimodel-emptyline"></div>
261 261  
262 -[[image:LSS-servo-ar-o-1.jpg]]
308 +Query Baud Rate (**QB**)<div class="wikimodel-emptyline"></div>
263 263  
264 -Query Angular Range (**QAR**)
310 +Ex: #5QB<cr> might return *5QB115200<cr><div class="wikimodel-emptyline"></div>
265 265  
266 -Example: #5QAR<cr> might return *5AR2756
312 +Since the command to query the baud rate must be done at the servo's existing baud rate, it can simply be used to confirm the CB configuration command was correctly received before the servo is power cycled and the new baud rate takes effect.<div class="wikimodel-emptyline"></div>
267 267  
268 -Configure Angular Range (**CAR**)
314 +Configure Baud Rate (**CB**)<div class="wikimodel-emptyline"></div>
269 269  
270 -This command allows you to change the total angular range of the servo in tenths of degrees in EEPROM. The setting will be saved upon servo reset / power cycle.
316 +**Important Note:** the servo's current session retains the given baud rate and the new baud rate will only take effect when the servo is power cycled / RESET.<div class="wikimodel-emptyline"></div>
271 271  
272 -====== __8. Position in Pulse (**P**)__ ======
318 +Ex: #5CB9600<cr><div class="wikimodel-emptyline"></div>
273 273  
274 -Example: #5P2334<cr>
320 +Sending this command will change the baud rate associated with servo ID 5 to 9600 bits per second.<div class="wikimodel-emptyline"></div>
321 +</div></div>
322 +{{/html}}
275 275  
276 -The position in PWM pulses was retained in order to be backward compatible with the SSC-32 / 32U protocol. This relates the desired angle with an RC standard PWM pulse and is further explained in the SSC-32 and SSC-32U manuals found on Lynxmotion.com. Without any modifications to configuration considered, and a ±90.0 degrees standard range where 1500 microseconds is centered, a pulse of 2334 would set the servo to 165.1 degrees. Valid values for P are [500, 2500]. Values outside this range are corrected to end points.
324 +== Motion ==
277 277  
278 -Query Position in Pulse (**QP**)
326 +====== __Position in Degrees (**D**)__ ======
279 279  
280 -Example: #5QP<cr> might return *5QP2334
328 +{{html wiki="true" clean="false"}}
329 +<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
330 +Example: #5D1456&lt;cr&gt;<div class="wikimodel-emptyline"></div>
281 281  
282 -This command queries the current angular position in PWM "units". The user must take into consideration that the response includes any angular range and origin configurations in order to determine the actual angle. 
283 -Valid values for QP are {-500, [500, 2500], -2500}. Values outside the [500, 2500] range are given a negative corresponding end point value to indicate they are out of bounds (note that if the servo is physically located at one of the endpoints, it may return a negative number if it is a fraction of a degree beyond the position).
332 +This moves the servo to an angle of 145.6 degrees, where the center (0) position is centered. Negative values (ex. -176 representing -17.6 degrees) could also be used. A full circle would be from -1800 to 1800 degrees. A value of 2700 would be the same angle (absolute position) as -900, except the servo would move in a different direction. <div class="wikimodel-emptyline"></div>
284 284  
285 -====== __9. Position in Degrees (**D**)__ ======
334 +Larger values are permitted and allow for multi-turn functionality using the concept of virtual position (explained above). <div class="wikimodel-emptyline"></div>
286 286  
287 -Example: #5PD1456<cr>
336 +Query Position in Degrees (**QD**)<div class="wikimodel-emptyline"></div>
288 288  
289 -This moves the servo to an angle of 145.6 degrees, where the center (0) position is centered. Negative values (ex. -176 representing -17.6 degrees) are used. A full circle would be from -1800 to 1800 degrees. A value of 2700 would be the same angle as -900, except the servo would move in a different direction.
338 +Example: #5QD&lt;cr&gt; might return *5QD132&lt;cr&gt;<div class="wikimodel-emptyline"></div>
290 290  
291 -Larger values are permitted and allow for multi-turn functionality using the concept of virtual position.
340 +This means the servo is located at 13.2 degrees.<div class="wikimodel-emptyline"></div>
292 292  
293 -Query Position in Degrees (**QD**)
342 +(% class="wikigeneratedid" id="H22.QueryTargetPositioninDegrees28QDT29" %)
343 +Query Target Position in Degrees (**QDT**)<div class="wikimodel-emptyline"></div>
294 294  
295 -Example: #5QD<cr> might return *5QD132<cr>
345 +Ex: #5QDT&lt;cr&gt; might return *5QDT6783&lt;cr&gt;<div class="wikimodel-emptyline"></div>
296 296  
297 -This means the servo is located at 13.2 degrees.
347 +The query target position command returns the target virtual position during and after an action which results in a rotation of the servo horn. In the example above, the servo is rotating to a virtual position of 678.3 degrees. Should the servo not have a target position or be in wheel mode, it will respond with the last target position used.
348 +<div class="wikimodel-emptyline"></div></div></div>
349 +{{/html}}
298 298  
299 -====== __10. Wheel Mode in Degrees (**WD**)__ ======
351 +====== __(Relative) Move in Degrees (**MD**)__ ======
300 300  
301 -Ex: #5WD900<cr>
353 +{{html wiki="true" clean="false"}}
354 +<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
355 +Example: #5MD123&lt;cr&gt;<div class="wikimodel-emptyline"></div>
302 302  
303 -This command sets the servo to wheel mode where it will rotate in the desired direction at the selected speed. The example above would have the servo rotate at 90.0 degrees per second clockwise (assuming factory default configurations).
357 +The relative move command causes the servo to read its current position and move the specified number of tenths of degrees in the corresponding position. For example if the servo is set to rotate CW (default) and an MD command of 123 is sent to the servo, it will cause the servo to rotate clockwise by 12.3 degrees. Negative commands would cause the servo to rotate in the opposite configured direction.
358 +<div class="wikimodel-emptyline"></div></div></div>
359 +{{/html}}
304 304  
305 -Query Wheel Mode in Degrees (**QWD**)
361 +====== __Wheel Mode in Degrees (**WD**)__ ======
306 306  
307 -Ex: #5QWD<cr> might return *5QWD900<cr>
363 +{{html wiki="true" clean="false"}}
364 +<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
365 +Ex: #5WD90&lt;cr&gt;<div class="wikimodel-emptyline"></div>
308 308  
309 -The servo replies with the angular speed in tenths of degrees per second. A negative sign would indicate the opposite direction (for factory default a negative value would be counter clockwise).
367 +This command sets the servo to wheel mode where it will rotate in the desired direction at the selected speed. The example above would have the servo rotate at 90.0 degrees per second clockwise (assuming factory default configurations).<div class="wikimodel-emptyline"></div>
310 310  
311 -====== __11. Wheel Mode in RPM (**WR**)__ ======
369 +Query Wheel Mode in Degrees (**QWD**)<div class="wikimodel-emptyline"></div>
312 312  
313 -Ex: #5WR40<cr>
371 +Ex: #5QWD&lt;cr&gt; might return *5QWD90&lt;cr&gt;<div class="wikimodel-emptyline"></div>
314 314  
315 -This command sets the servo to wheel mode where it will rotate in the desired direction at the selected rpm. Wheel mode (a.k.a. "continuous rotation") has the servo operate like a geared DC motor. The servo's maximum rpm cannot be set higher than its physical limit at a given voltage. The example above would have the servo rotate at 40 rpm clockwise (assuming factory default configurations).
373 +The servo replies with the angular speed in degrees per second. A negative sign would indicate the opposite direction (for factory default a negative value would be counter clockwise).
374 +<div class="wikimodel-emptyline"></div></div></div>
375 +{{/html}}
316 316  
317 -Query Wheel Mode in RPM (**QWR**)
377 +====== __Wheel Mode in RPM (**WR**)__ ======
318 318  
319 -Ex: #5QWR<cr> might return *5QWR40<cr>
379 +{{html wiki="true" clean="false"}}
380 +<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
381 +Ex: #5WR40&lt;cr&gt;<div class="wikimodel-emptyline"></div>
320 320  
383 +This command sets the servo to wheel mode where it will rotate in the desired direction at the selected rpm. Wheel mode (a.k.a. "continuous rotation") has the servo operate like a geared DC motor. The servo's maximum rpm cannot be set higher than its physical limit at a given voltage. The example above would have the servo rotate at 40 rpm clockwise (assuming factory default configurations).<div class="wikimodel-emptyline"></div>
384 +
385 +Query Wheel Mode in RPM (**QWR**)<div class="wikimodel-emptyline"></div>
386 +
387 +Ex: #5QWR&lt;cr&gt; might return *5QWR40&lt;cr&gt;<div class="wikimodel-emptyline"></div>
388 +
321 321  The servo replies with the angular speed in rpm. A negative sign would indicate the opposite direction (for factory default a negative value would be counter clockwise).
390 +<div class="wikimodel-emptyline"></div></div></div>
391 +{{/html}}
322 322  
323 -====== __12. Speed in Degrees (**SD**)__ ======
393 +====== __Position in PWM (**P**)__ ======
324 324  
325 -Ex: #5SD1800<cr>
395 +{{html wiki="true" clean="false"}}
396 +<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
397 +Example: #5P2334&lt;cr&gt;<div class="wikimodel-emptyline"></div>
326 326  
327 -This command sets the servo's maximum speed for action commands in tenths of degrees per second for that session. In the example above, the servo's maximum speed for that session would be set to 180.0 degrees per second. Therefore maximum speed for actions can be set "on the fly". The servo's maximum speed cannot be set higher than its physical limit at a given voltage. SD overrides CSD (described below) for that session. Upon reset or power cycle, the servo reverts to the value associated with CSD as described below. Note that SD and SR (described below) are effectively the same, but allow the user to specify the speed in either unit. The last command (either SR or SD) is what the servo uses for that session.
399 +The position in PWM pulses was retained in order to be backward compatible with the SSC-32 / 32U protocol. This relates the desired angle with an RC standard PWM signal and is further explained in the SSC-32 and [[SSC-32U manuals>>https://www.robotshop.com/media/files/pdf2/lynxmotion_ssc-32u_usb_user_guide.pdf#page=24]]. Without any modifications to configuration considered, and a ±90.0 degrees standard range where 1500 microseconds is centered, a PWM signal of 2334 would set the servo to 165.1 degrees. Valid values for P are [500, 2500]. Values outside this range are corrected / restricted to end points.<div class="wikimodel-emptyline"></div>
328 328  
329 -Query Speed in Degrees (**QSD**)
401 +Query Position in Pulse (**QP**)<div class="wikimodel-emptyline"></div>
330 330  
331 -Ex: #5QSD<cr> might return *5QSD1800<cr>
403 +Example: #5QP&lt;cr&gt; might return *5QP2334<div class="wikimodel-emptyline"></div>
332 332  
333 -By default QSD will return the current session value, which is set to the value of CSD as reset/power cycle and changed whenever a SD/SR command is processed.
334 -If #5QSD1<cr> is sent, the configured maximum speed (CSD value) will be returned instead. You can also query the current speed using "2" and the current target travel speed using "3". See the table below for an example:
405 +This command queries the current angular position in PWM "units". The user must take into consideration that the response includes any angular range and origin configurations in order to determine the actual angle.
406 +Valid values for QP are {-500, [500, 2500], -2500}. Values outside the [500, 2500] range are given a negative corresponding end point value to indicate they are out of bounds (note that if the servo is physically located at one of the endpoints, it may return a negative number if it is a fraction of a degree beyond the position).
407 +<div class="wikimodel-emptyline"></div></div></div>
408 +{{/html}}
335 335  
336 -|**Command sent**|**Returned value (1/10 °)**
337 -|ex: #5QSD<cr>|Session value for maximum speed (set by latest SD/SR command)
338 -|ex: #5QSD1<cr>|Configured maximum speed  (set by CSD/CSR)
339 -|ex: #5QSD2<cr>|Instantaneous speed (same as QWD)
340 -|ex: #5QSD3<cr>|Target travel speed
410 +====== __(Relative) Move in PWM (**M**)__ ======
341 341  
342 -Configure Speed in Degrees (**CSD**)
412 +{{html wiki="true" clean="false"}}
413 +<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
414 +Example: #5M1500&lt;cr&gt;<div class="wikimodel-emptyline"></div>
343 343  
344 -Ex: #5CSD1800<cr>
416 +The relative move in PWM command causes the servo to read its current position and move by the specified number of PWM signal. For example if the servo is set to rotate CW (default) and an M command of 1500 is sent to the servo, it will cause the servo to rotate clockwise by 90 degrees. Negative PWM value would cause the servo to rotate in the opposite configured direction.
417 +<div class="wikimodel-emptyline"></div></div></div>
418 +{{/html}}
345 345  
346 -Using the CSD command sets the servo's maximum speed which is saved in EEPROM. In the example above, the servo's maximum speed will be set to 180.0 degrees per second. When the servo is powered on (or after a reset), the CSD value is used. Note that CSD and CSR (described below) are effectively the same, but allow the user to specify the speed in either unit. The last command (either CSR or CSD) is what the servo uses for that session.
420 +====== __Raw Duty-cycle Move (**RDM**)__ ======
347 347  
348 -====== __13. Speed in RPM (**SR**)__ ======
422 +{{html wiki="true" clean="false"}}
423 +<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
424 +Example: #5RDM512&lt;cr&gt;<div class="wikimodel-emptyline"></div>
349 349  
350 -Ex: #5SD45<cr>
426 +The raw duty-cycle move command (or free move command) will rotate the servo at a specified duty cycle value in wheel mode (a.k.a. "continuous rotation") like a geared DC motor.<div class="wikimodel-emptyline"></div>
351 351  
352 -This command sets the servo's maximum speed for action commands in rpm for that session. In the example above, the servo's maximum speed for that session would be set to 45rpm. Therefore maximum speed for actions can be set "on the fly". The servo's maximum speed cannot be set higher than its physical limit at a given voltage. SD overrides CSD (described below) for that session. Upon reset or power cycle, the servo reverts to the value associated with CSD as described below. Note that SD (described above) and SR are effectively the same, but allow the user to specify the speed in either unit. The last command (either SR or SD) is what the servo uses for that session.
428 +The duty values range from 0 to 1023. Negative values will rotate the servo in the opposite direction (for factory default a negative value would be counter clockwise).<div class="wikimodel-emptyline"></div>
353 353  
354 -Query Speed in Degrees (**QSR**)
430 +Query Move in Duty-cycle (**QMD**)<div class="wikimodel-emptyline"></div>
355 355  
356 -Ex: #5QSR<cr> might return *5QSR45<cr>
432 +Example: #5QMD&lt;cr&gt; might return *5QMD512<div class="wikimodel-emptyline"></div>
357 357  
358 -By default QSR will return the current session value, which is set to the value of CSR as reset/power cycle and changed whenever a SD/SR command is processed.
359 -If #5QSR1<cr> is sent, the configured maximum speed (CSR value) will be returned instead. You can also query the current speed using "2" and the current target travel speed using "3". See the table below for an example:
434 +This command queries the raw duty-cycle move value. 512 value means that the motor is rotating at 50% duty-cycle.
435 +<div class="wikimodel-emptyline"></div></div></div>
436 +{{/html}}
360 360  
361 -|**Command sent**|**Returned value (1/10 °)**
362 -|ex: #5QSR<cr>|Session value for maximum speed (set by latest SD/SR command)
363 -|ex: #5QSR1<cr>|Configured maximum speed  (set by CSD/CSR)
364 -|ex: #5QSR2<cr>|Instantaneous speed (same as QWR)
365 -|ex: #5QSR3<cr>|Target travel speed
438 +====== __Query Status (**Q**)__ ======
366 366  
367 -Configure Speed in RPM (**CSR**)
440 +{{html wiki="true" clean="false"}}
441 +<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
442 +The status query describes what the servo is currently doing. The query returns an integer which must be looked up in the table below.<div class="wikimodel-emptyline"></div>
368 368  
369 -Ex: #5CSR45<cr>
444 +Ex: #5Q&lt;cr&gt; might return *5Q6&lt;cr&gt;, which indicates the motor is holding a position.<div class="wikimodel-emptyline"></div>
445 +</div></div>
446 +{{/html}}
370 370  
371 -Using the CSR command sets the servo's maximum speed which is saved in EEPROM. In the example above, the servo's maximum speed will be set to 45rpm. When the servo is powered on (or after a reset), the CSR value is used. Note that CSD and CSR are effectively the same, but allow the user to specify the speed in either unit. The last command (either CSR or CSD) is what the servo uses for that session.
448 +|(% style="width:25px" %) |***Value returned (Q)**|**Status**|**Detailed description**
449 +| |ex: *5Q0<cr>|0: Unknown|LSS is unsure / unknown state
450 +| |ex: *5Q1<cr>|1: Limp|Motor driving circuit is not powered and horn can be moved freely
451 +| |ex: *5Q2<cr>|2: Free moving|Servo is rotating in duty motion / free move using the RDM command
452 +| |ex: *5Q3<cr>|3: Accelerating|Increasing speed from rest (or previous speed) towards travel speed
453 +| |ex: *5Q4<cr>|4: Traveling|Moving at a stable speed
454 +| |ex: *5Q5<cr>|5: Decelerating|Decreasing from travel speed towards final position.
455 +| |ex: *5Q6<cr>|6: Holding|Keeping current position
456 +| |ex: *5Q7<cr>|7: Outside limits|{More details coming soon}
457 +| |ex: *5Q8<cr>|8: Stuck|Motor cannot perform request movement at current speed setting
458 +| |ex: *5Q9<cr>|9: Blocked|Similar to stuck, but the motor is at maximum duty and still cannot move (i.e.: stalled)
459 +| |ex: *5Q10<cr>|10: Safe Mode|(((
460 +A safety limit has been exceeded (temperature, peak current or extended high current draw).
372 372  
373 -====== __14. Angular Stiffness (**AS**)__ ======
462 +Send a Q1 command to know which limit has been reached (described below).
463 +)))
374 374  
375 -The servo's rigidity / angular stiffness can be thought of as (though not identical to) a damped spring in which the value affects the stiffness and embodies how much, and how quickly the servo tried keep the requested position against changes.
465 +{{html wiki="true" clean="false"}}
466 +<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
467 +If a safety limit has been reached and exceeded, the LED will flash red and the servo will stop providing torque (no longer react to commands which cause the motor to rotate). In order to determine which limit has been reached, send a Q1 command. The servo must be RESET in order to return to normal operation, though if a limit is still detected (for example the servo is still too hot), it will revert back to Safe Mode.<div class="wikimodel-emptyline"></div>
468 +</div></div>
469 +{{/html}}
376 376  
377 -A positive value of "angular stiffness":
471 +|(% style="width:25px" %) |***Value returned (Q1)**|**Status**|**Detailed description**
472 +| |ex: *5Q0<cr>|No limits have been passed|Nothing is wrong
473 +| |ex: *5Q1<cr>|Current limit has been passed|Something cause the current to either spike, or remain too high for too long
474 +| |ex: *5Q2<cr>|Input voltage detected is below or above acceptable range|Check the voltage of your batteries or power source
475 +| |ex: *5Q3<cr>|Temperature limit has been reached|The servo is too hot to continue operating safely.
378 378  
379 -* The more torque will be applied to try to keep the desired position against external input / changes
380 -* The faster the motor will reach its intended travel speed and the motor will decelerate faster and nearer to its target position
477 +====== __Limp (**L**)__ ======
381 381  
382 -A negative value on the other hand:
479 +{{html wiki="true" clean="false"}}
480 +<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
481 +Example: #5L&lt;cr&gt;<div class="wikimodel-emptyline"></div>
383 383  
384 -* Causes a slower acceleration to the travel speed, and a slower deceleration
385 -* Allows the target position to deviate more from its position before additional torque is applied to bring it back
483 +This action causes the servo to go "limp". The microcontroller will still be powered, but the motor will not. As an emergency safety feature, should the robot not be doing what it is supposed to or risks damage, use the broadcast ID to set all servos limp #254L&lt;cr&gt;.
484 +<div class="wikimodel-emptyline"></div></div></div>
485 +{{/html}}
386 386  
387 -The default value is zero and the effect becomes extreme by -4, +4. There are no units, only integers between -4 to 4. Greater values produce increasingly erratic behavior.
487 +====== __Halt & Hold (**H**)__ ======
388 388  
389 -Ex: #5AS-2<cr>
489 +{{html wiki="true" clean="false"}}
490 +<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
491 +Example: #5H&lt;cr&gt;<div class="wikimodel-emptyline"></div>
390 390  
391 -This reduces the angular stiffness to -2 for that session, allowing the servo to deviate more around the desired position. This can be beneficial in many situations such as impacts (legged robots) where more of a "spring" effect is desired. Upon reset, the servo will use the value stored in memory, based on the last configuration command.
493 +This command causes the servo to stop immediately and hold that angular position. It overrides whatever the servo might be doing at the time the command is received (accelerating, travelling, deccelerating, etc.)
494 +<div class="wikimodel-emptyline"></div></div></div>
495 +{{/html}}
392 392  
393 -Ex: #5QAS<cr>
497 +== Motion Setup ==
394 394  
395 -Queries the value being used.
499 +====== __Enable Motion Profile (**EM**)__ ======
396 396  
397 -Ex: #5CAS<cr>
501 +{{html wiki="true" clean="false"}}
502 +<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
503 +Ex: #5EM1&lt;cr&gt;<div class="wikimodel-emptyline"></div>
398 398  
399 -Writes the desired angular stiffness value to memory.
505 +This command enables a trapezoidal motion profile. By default, the trapezoidal motion profile is enabled. If the motion profile is enabled, angular acceleration (AA) and angular deceleration(AD) will have an effect on the motion. Also, SD/S and T modifiers can be used.<div class="wikimodel-emptyline"></div>
400 400  
401 -====== __15. Angular Hold Stiffness (**AH**)__ ======
507 +Ex: #5EM0&lt;cr&gt;<div class="wikimodel-emptyline"></div>
402 402  
403 -The angular holding stiffness determines the servo's ability to hold a desired position under load. Values can be from -10 to 10, with the default being 0. Note that negative values mean the final position can be easily deflected.
509 +This command will disable the trapezoidal motion profile. As such, the servo will move at full speed for D/MD action commands. Angular acceleration (AA) and angular deceleration(AD) won't have an effect on motion in this mode and modifiers SD/S or T cannot be used.<div class="wikimodel-emptyline"></div>
404 404  
405 -Ex: #5AH3<cr>
511 +Query Motion Profile (**QEM**)<div class="wikimodel-emptyline"></div>
406 406  
407 -This sets the holding stiffness for servo #5 to 3 for that session.
513 +Ex: #5QEM&lt;cr&gt; might return *5QEM1&lt;cr&gt;<div class="wikimodel-emptyline"></div>
408 408  
409 -Query Angular Hold Stiffness (**QAH**)
515 +This command will query the motion profile. **0:** motion profile disabled / **1:** trapezoidal motion profile enabled.<div class="wikimodel-emptyline"></div>
410 410  
411 -Ex: #5QAH<cr> might return *5QAH3<cr>
517 +Configure Motion Profile (**CEM**)<div class="wikimodel-emptyline"></div>
412 412  
413 -This returns the servo's angular holding stiffness value.
519 +Ex: #5CEM0&lt;cr&gt;<div class="wikimodel-emptyline"></div>
414 414  
415 -Configure Angular Hold Stiffness (**CAH**)
521 +This command configures the motion profile and saves it in the EEPROM. The setting will be saved upon servo reset / power cycle.
522 +<div class="wikimodel-emptyline"></div></div></div>
523 +{{/html}}
416 416  
417 -Ex: #5CAH2<cr>
525 +====== __Filter Position Count (**FPC**)__ ======
418 418  
419 -This writes the angular holding stiffness of servo #5 to 2 to EEPROM
527 +{{html wiki="true" clean="false"}}
528 +<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
529 +Ex: #5FPC10&lt;cr&gt;<div class="wikimodel-emptyline"></div>
530 +This command allows the user to change the Filter Position Count value for that session. <div class="wikimodel-emptyline"></div>
420 420  
421 -====== __15b: Angular Acceleration (**AA**)__ ======
532 +Query Filter Position Count (**QFPC**)<div class="wikimodel-emptyline"></div>
422 422  
423 -{More details to come}
534 +Ex: #5QFPC&lt;cr&gt; might return *5QFPC10&lt;cr&gt;<div class="wikimodel-emptyline"></div>
424 424  
425 -====== __15c: Angular Deceleration (**AD**)__ ======
536 +This command will query the Filter Position Count value.<div class="wikimodel-emptyline"></div>
426 426  
427 -{More details to come}
538 +Configure Filter Position Count (**CFPC**)<div class="wikimodel-emptyline"></div>
428 428  
429 -====== __15d: Motion Control (**EM**)__ ======
540 +Ex: #5CFPC10&lt;cr&gt;<div class="wikimodel-emptyline"></div>
430 430  
431 -{More details to come}
542 +This command configures the Filter Position Count value and saves it in the EEPROM. The setting will be saved upon servo reset / power cycle.
543 +<div class="wikimodel-emptyline"></div></div></div>
544 +{{/html}}
432 432  
433 -====== __16. RGB LED (**LED**)__ ======
546 +====== __Origin Offset (**O**)__ ======
434 434  
435 -Ex: #5LED3<cr>
548 +{{html wiki="true" clean="false"}}
549 +<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
550 +Example: #5O2400&lt;cr&gt;<div class="wikimodel-emptyline"></div>
436 436  
437 -This action sets the servo's RGB LED color for that session.The LED can be used for aesthetics, or (based on user code) to provide visual status updates. Using timing can create patterns.
552 +This command allows you to change the origin of the servo in relation to the factory zero position for that session. As with all action commands, the setting will be lost upon servo reset / power cycle. Origin offset commands are not cumulative and always relate to factory zero. In the first image, the origin at factory offset '0' (centered).<div class="wikimodel-emptyline"></div>
438 438  
439 -0=OFF 1=RED 2=GREEN 3= BLUE 4=YELLOW 5=CYAN 6= 7=MAGENTA, 8=WHITE 
554 +[[image:LSS-servo-default.jpg]]<div class="wikimodel-emptyline"></div>
440 440  
441 -Query LED Color (**QLED**)
556 +In the second image, the origin, and the corresponding angular range (explained below) have been shifted by +240.0 degrees:<div class="wikimodel-emptyline"></div>
442 442  
443 -Ex: #5QLED<cr> might return *5QLED5<cr>
558 +[[image:LSS-servo-origin.jpg]]<div class="wikimodel-emptyline"></div>
444 444  
445 -This simple query returns the indicated servo's LED color.
560 +Origin Offset Query (**QO**)<div class="wikimodel-emptyline"></div>
446 446  
447 -Configure LED Color (**CLED**)
562 +Example: #5QO&lt;cr&gt; might return *5QO-13<div class="wikimodel-emptyline"></div>
448 448  
449 -Configuring the LED color via the CLED command sets the startup color of the servo after a reset or power cycle. Note that it also changes the session's LED color immediately as well.
564 +This allows you to query the angle (in tenths of degrees) of the origin in relation to the factory zero position. In this example, the new origin is at -1.3 degrees from the factory zero.<div class="wikimodel-emptyline"></div>
450 450  
451 -====== __16b. Configure LED Blinking (**CLB**)__ ======
566 +Configure Origin Offset (**CO**)<div class="wikimodel-emptyline"></div>
452 452  
453 -This command allows you to control when the RGB LED will blink the user set color (see [[16. RGB LED>>||anchor="H16.RGBLED28LED29"]] for details).
454 -You can turn on or off blinking for various LSS status. Here is the list and their associated value: 0=No blinking, ; 63=Always blink; Blink while: 1=Limp; 2=Holding 4=Accel; 8=Decel; 16=Free 32=Travel;
568 +Example: #5CO-24&lt;cr&gt;<div class="wikimodel-emptyline"></div>
455 455  
456 -To set blinking, use CLB with the value of your choosing. To activate blinking in multiple status, simply add together the values of the corresponding status. See examples below:
570 +This command allows you to change the origin of the servo in relation to the factory zero position in EEPROM. The setting will be saved upon servo reset / power cycle. Origin offset configuration commands are not cumulative and always relate to factory zero. The new origin is also used in RC mode. In the example, the new origin will be at -2.4 degrees from the factory zero.
571 +<div class="wikimodel-emptyline"></div></div></div>
572 +{{/html}}
457 457  
458 -Ex: #5CLB0<cr> to turn off all blinking (LED always solid)
459 -Ex: #5CLB1<cr> only blink when limp
460 -Ex: #5CLB2<cr> only blink when holding
461 -Ex: #5CLB12<cr> only blink when accel or decel
462 -Ex: #5CLB48<cr> only blink when free or travel
463 -Ex: #5CLB63<cr> blink in all status
574 +====== __Angular Range (**AR**)__ ======
464 464  
465 -====== __17. Identification Number__ ======
576 +{{html wiki="true" clean="false"}}
577 +<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
578 +Example: #5AR1800&lt;cr&gt;<div class="wikimodel-emptyline"></div>
466 466  
467 -A servo's identification number cannot be set "on the fly" and must be configured via the CID command described below. The factory default ID number for all servos is 0. Since smart servos are intended to be daisy chained, in order to respond differently from one another, the user must set different identification numbers. Servos with the same ID and baud rate will all receive and react to the same commands.
580 +This command allows you to temporarily change the total angular range of the servo in tenths of degrees. This applies to the Position in Pulse (P) command and RC mode. The default for (P) and RC mode is 1800 (180.0 degrees total, or ±90.0 degrees). The image below shows a standard -180.0 to +180.0 range, with no offset:<div class="wikimodel-emptyline"></div>
468 468  
469 -Query Identification (**QID**)
582 +[[image:LSS-servo-default.jpg]]<div class="wikimodel-emptyline"></div>
470 470  
471 -EX: #254QID<cr> might return *QID5<cr>
584 +Below, the angular range is restricted to 180.0 degrees, or -90.0 to +90.0. The center has remained unchanged.<div class="wikimodel-emptyline"></div>
472 472  
473 -When using the query ID command, it is best to only have one servo connected and thus receive only one reply using the broadcast command (ID 254). Alternatively, pushing the button upon startup and temporarily setting the servo ID to 255 will still result in the servo responding with its "real" ID.
586 +[[image:LSS-servo-ar.jpg]]<div class="wikimodel-emptyline"></div>
474 474  
475 -Configure ID (**CID**)
588 +Finally, the angular range action command (ex. #5AR1800&lt;cr&gt;) and origin offset action command (ex. #5O-1200&lt;cr&gt;) are used to move both the center and limit the angular range:<div class="wikimodel-emptyline"></div>
476 476  
477 -Ex: #4CID5<cr>
590 +[[image:LSS-servo-ar-o-1.jpg]]<div class="wikimodel-emptyline"></div>
478 478  
479 -Setting a servo's ID in EEPROM is done via the CID command. All servos connected to the same serial bus will be assigned that ID. In most situations each servo must be set a unique ID, which means each servo must be connected individually to the serial bus and receive a unique CID number. It is best to do this before the servos are added to an assembly. Numbered stickers are provided to distinguish each servo after their ID is set, though you are free to use whatever alternative method you like.
592 +Query Angular Range (**QAR**)<div class="wikimodel-emptyline"></div>
480 480  
481 -====== __18. Baud Rate__ ======
594 +Example: #5QAR&lt;cr&gt; might return *5AR1800, indicating the total angular range is 180.0 degrees.<div class="wikimodel-emptyline"></div>
482 482  
483 -A servo's baud rate cannot be set "on the fly" and must be configured via the CB command described below. The factory default baud rate for all servos is 9600. Since smart servos are intended to be daisy chained, in order to respond to the same serial bus, all servos in that project should ideally be set to the same baud rate. Setting different baud rates will have the servos respond differently and may create issues. Available baud rates are: 9.6 kbps, 19.2 kbps, 38.4 kbps, 57.6 kbps, 115.2 kbps, 230.4 kbps, 250.0 kbps, 460.8 kbps, 500.0 kbps, 750.0 kbps*, 921.6 kbps*. Servos are shipped with a baud rate set to 9600. The baud rates are currently restricted to those above.
484 -\*: Current tests reveal baud rates above 500 kbps are unstable and can cause timeouts. Please keep this in mind if using those / testing them out.
596 +Configure Angular Range (**CAR**)<div class="wikimodel-emptyline"></div>
485 485  
486 -Query Baud Rate (**QB**)
598 +This command allows you to change the total angular range of the servo in tenths of degrees in EEPROM. The setting will be saved upon servo reset / power cycle.
599 +<div class="wikimodel-emptyline"></div></div></div>
600 +{{/html}}
487 487  
488 -Ex: #5QB<cr> might return *5QB9600<cr>
602 +====== __Angular Stiffness (**AS**)__ ======
489 489  
490 -Querying the baud rate is used simply to confirm the CB configuration command before the servo is power cycled.
604 +{{html wiki="true" clean="false"}}
605 +<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
606 +The servo's rigidity / angular stiffness can be thought of as (though not identical to) a damped spring in which the value affects the stiffness and embodies how much, and how quickly the servo tried keep the requested position against changes. There are no units.<div class="wikimodel-emptyline"></div>
491 491  
492 -Configure Baud Rate (**CB**)
608 +A higher value of "angular stiffness":<div class="wikimodel-emptyline"></div>
493 493  
494 -Important Note: the servo's current session retains the given baud rate and the new baud rate will only be in place when the servo is power cycled.
610 +* The more torque will be applied to try to keep the desired position against external input / changes
611 +* The faster the motor will reach its intended travel speed and the motor will decelerate faster and nearer to its target position<div class="wikimodel-emptyline"></div>
495 495  
496 -Ex: #5CB9600<cr>
613 +A lower value on the other hand:<div class="wikimodel-emptyline"></div>
497 497  
498 -Sending this command will change the baud rate associated with servo ID 5 to 9600 bits per second.
615 +* Causes a slower acceleration to the travel speed, and a slower deceleration
616 +* Allows the target position to deviate more from its position before additional torque is applied to bring it back<div class="wikimodel-emptyline"></div>
499 499  
500 -====== __19. Gyre Rotation Direction__ ======
618 +The default value for stiffness depending on the firmware may be 0 or 1. Greater values produce increasingly erratic behavior and the effect becomes extreme below -4 and above +4. Maximum values are -10 to +10.<div class="wikimodel-emptyline"></div>
501 501  
502 -"Gyre" is defined as a circular course or motion. The effect of changing the gyre direction is as if you were to use a mirror image of a circle. CW = 1; CCW = -1. The factory default is clockwise (CW).
620 +Ex: #5AS-2&lt;cr&gt;<div class="wikimodel-emptyline"></div>
503 503  
504 -{images showing before and after with AR and Origin offset}
622 +This reduces the angular stiffness to -2 for that session, allowing the servo to deviate more around the desired position. This can be beneficial in many situations such as impacts (legged robots) where more of a "spring" effect is desired. Upon reset, the servo will use the value stored in memory, based on the last configuration command.<div class="wikimodel-emptyline"></div>
505 505  
506 -Query Gyre Direction (**QG**)
624 +Ex: #5QAS&lt;cr&gt;<div class="wikimodel-emptyline"></div>
507 507  
508 -Ex: #5QG<cr> might return *5QG-1<cr>
626 +Queries the value being used.<div class="wikimodel-emptyline"></div>
509 509  
510 -The value returned above means the servo is in a counter-clockwise gyration.
628 +Ex: #5CAS-2&lt;cr&gt;<div class="wikimodel-emptyline"></div>
511 511  
512 -Configure Gyre (**CG**)
630 +Writes the desired angular stiffness value to EEPROM.
631 +<div class="wikimodel-emptyline"></div></div></div>
632 +{{/html}}
513 513  
514 -Ex: #5CG-1<cr>
634 +====== __Angular Holding Stiffness (**AH**)__ ======
515 515  
516 -This changes the gyre direction as described above and also writes to EEPROM.
636 +{{html wiki="true" clean="false"}}
637 +<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
638 +The angular holding stiffness determines the servo's ability to hold a desired position under load. The default value for stiffness depending on the firmware may be 0 or 1. Greater values produce increasingly erratic behavior and the effect becomes extreme below -4 and above +4. Maximum values are -10 to +10.<div class="wikimodel-emptyline"></div>
517 517  
518 -====== __20. First / Initial Position (pulse)__ ======
640 +Ex: #5AH3&lt;cr&gt;<div class="wikimodel-emptyline"></div>
519 519  
520 -In certain cases, a user might want to have the servo move to a specific angle upon power up. We refer to this as "first position". The factory default has no first position value stored in EEPROM and therefore upon power up, the servo remains limp until a position (or hold command) is assigned. FP and FD are different in that FP is used for RC mode only, whereas FD is used for smart mode only.
642 +This sets the holding stiffness for servo #5 to 3 for that session.<div class="wikimodel-emptyline"></div>
521 521  
522 -Query First Position in Pulses (**QFP**)
644 +Query Angular Holding Stiffness (**QAH**)<div class="wikimodel-emptyline"></div>
523 523  
524 -Ex: #5QFP<cr> might return *5QFP1550<cr>
646 +Ex: #5QAH&lt;cr&gt; might return *5QAH3&lt;cr&gt;<div class="wikimodel-emptyline"></div>
525 525  
526 -The reply above indicates that servo with ID 5 has a first position pulse of 1550 microseconds. If no first position has been set, servo will respond with DIS ("disabled").
648 +This returns the servo's angular holding stiffness value.<div class="wikimodel-emptyline"></div>
527 527  
528 -Configure First Position in Pulses (**CFP**)
650 +Configure Angular Holding Stiffness (**CAH**)<div class="wikimodel-emptyline"></div>
529 529  
530 -Ex: #5CP1550<cr>
652 +Ex: #5CAH2&lt;cr&gt;<div class="wikimodel-emptyline"></div>
531 531  
532 -This configuration command means the servo, when set to RC mode, will immediately move to an angle equivalent to having received an RC pulse of 1550 microseconds upon power up. Sending a CFP command without a number results in the servo remaining limp upon power up (i.e. disabled).
654 +This writes the angular holding stiffness of servo #5 to 2 to EEPROM.
655 +<div class="wikimodel-emptyline"></div></div></div>
656 +{{/html}}
533 533  
534 -====== __21. First / Initial Position (Degrees)__ ======
658 +====== __Angular Acceleration (**AA**)__ ======
535 535  
536 -In certain cases, a user might want to have the servo move to a specific angle upon power up. We refer to this as "first position". The factory default has no first position value stored in EEPROM and therefore upon power up, the servo remains limp until a position (or hold command) is assigned. FP and FD are different in that FP is used for RC mode only, whereas FD is used for smart mode only.
660 +{{html wiki="true" clean="false"}}
661 +<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
662 +The default value for angular acceleration is 100. Accepts values of between 1 and 100. Increments of 10 degrees per second squared.<div class="wikimodel-emptyline"></div>
537 537  
538 -Query First Position in Degrees (**QFD**)
664 +Ex: #5AA30&lt;cr&gt;<div class="wikimodel-emptyline"></div>
539 539  
540 -Ex: #5QFD<cr> might return *5QFD64<cr>
666 +This sets the angular acceleration for servo #5 to 30 degrees per second squared (°/s^^2^^).<div class="wikimodel-emptyline"></div>
541 541  
542 -The reply above indicates that servo with ID 5 has a first position pulse of 1550 microseconds.
668 +Query Angular Acceleration (**QAA**)<div class="wikimodel-emptyline"></div>
543 543  
544 -Configure First Position in Degrees (**CFD**)
670 +Ex: #5QAA&lt;cr&gt; might return *5QAA30&lt;cr&gt;<div class="wikimodel-emptyline"></div>
545 545  
546 -Ex: #5CD64<cr>
672 +This returns the servo's angular acceleration in degrees per second squared (°/s^^2^^).<div class="wikimodel-emptyline"></div>
547 547  
548 -This configuration command means the servo, when set to smart mode, will immediately move to 6.4 degrees upon power up. Sending a CFD command without a number results in the servo remaining limp upon power up.
674 +Configure Angular Acceleration (**CAA**)<div class="wikimodel-emptyline"></div>
549 549  
550 -====== __22. Query Target Position in Degrees (**QDT**)__ ======
676 +Ex: #5CAA30&lt;cr&gt;<div class="wikimodel-emptyline"></div>
551 551  
552 -Ex: #5QDT<cr> might return *5QDT6783<cr>
678 +This writes the angular acceleration of servo #5 to 30 degrees per second squared (°/s^^2^^) to EEPROM.
679 +<div class="wikimodel-emptyline"></div></div></div>
680 +{{/html}}
553 553  
554 -The query target position command returns the target angle during and after an action which results in a rotation of the servo horn. In the example above, the servo is rotating to a virtual position of 678.3 degrees. Should the servo not have a target position or be in wheel mode, it will respond without a number (Ex: *5QDT<cr>).
682 +====== __Angular Deceleration (**AD**)__ ======
555 555  
556 -====== __23. Query Model String (**QMS**)__ ======
684 +{{html wiki="true" clean="false"}}
685 +<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
686 +The default value for angular deceleration is 100. Accepts values of between 1 and 100. Increments of 10 degrees per second squared.<div class="wikimodel-emptyline"></div>
557 557  
558 -Ex: #5QMS<cr> might return *5QMSLSS-HS1cr>
688 +Ex: #5AD30&lt;cr&gt;<div class="wikimodel-emptyline"></div>
559 559  
560 -This reply means the servo model is LSS-HS1, meaning a high speed servo, first revision.
690 +This sets the angular deceleration for servo #5 to 30 degrees per second squared (°/s^^2^^).<div class="wikimodel-emptyline"></div>
561 561  
562 -====== __23b. Query Model (**QM**)__ ======
692 +Query Angular Deceleration (**QAD**)<div class="wikimodel-emptyline"></div>
563 563  
564 -Ex: #5QM<cr> might return *5QM68702699520cr>
694 +Ex: #5QAD&lt;cr&gt; might return *5QAD30&lt;cr&gt;<div class="wikimodel-emptyline"></div>
565 565  
566 -This reply means the servo model is 0xFFF000000 or 100, meaning a high speed servo, first revision.
696 +This returns the servo's angular deceleration in degrees per second squared (°/s^^2^^).<div class="wikimodel-emptyline"></div>
567 567  
568 -====== __24. Query Serial Number (**QN**)__ ======
698 +Configure Angular Deceleration (**CAD**)<div class="wikimodel-emptyline"></div>
569 569  
570 -Ex: #5QN<cr> might return *5QN~_~_<cr>
700 +Ex: #5CAD30&lt;cr&gt;<div class="wikimodel-emptyline"></div>
571 571  
572 -The number in the response is the servo's serial number which is set and cannot be changed.
702 +This writes the angular deceleration of servo #5 to 30 degrees per second squared (°/s^^2^^) to EEPROM.
703 +<div class="wikimodel-emptyline"></div></div></div>
704 +{{/html}}
573 573  
574 -====== __25. Query Firmware (**QF**)__ ======
706 +====== __Gyre Direction (**G**)__ ======
575 575  
576 -Ex: #5QF<cr> might return *5QF11<cr>
708 +{{html wiki="true" clean="false"}}
709 +<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
710 +"Gyre" is defined as a circular course or motion. The effect of changing the gyre direction is as if you were to use a mirror image of a circle. By default: CW = 1; CCW = -1.<div class="wikimodel-emptyline"></div>
577 577  
578 -The integer in the reply represents the firmware version with one decimal, in this example being 1.1
712 +Ex: #5G-1&lt;cr&gt;<div class="wikimodel-emptyline"></div>
579 579  
580 -====== __26. Query Status (**Q**)__ ======
714 +This command will cause servo #5's positions to be inverted, effectively causing the servo to rotate in the opposite direction given the same command. For example in a 2WD robot, servos are often physically installed back to back, therefore setting one of the servos to a negative gyration, the same wheel command (ex WR30) to both servos will cause the robot to move forward or backward rather than rotate.<div class="wikimodel-emptyline"></div>
581 581  
582 -Ex: #5Q<cr> might return *5Q6<cr>, which indicates the motor is holding a position.
716 +Query Gyre Direction (**QG**)<div class="wikimodel-emptyline"></div>
583 583  
584 -|*Value returned|**Status**|**Detailed description**
585 -|ex: *5Q0<cr>|Unknown|LSS is unsure
586 -|ex: *5Q1<cr>|Limp|Motor driving circuit is not powered and horn can be moved freely
587 -|ex: *5Q2<cr>|Free moving|Motor driving circuit is not powered and horn can be moved freely
588 -|ex: *5Q3<cr>|Accelerating|Increasing speed from rest (or previous speeD) towards travel speed
589 -|ex: *5Q4<cr>|Traveling|Moving at a stable speed
590 -|ex: *5Q5<cr>|Decelerating|Decreasing from travel speed towards final position.
591 -|ex: *5Q6<cr>|Holding|Keeping current position
592 -|ex: *5Q7<cr>|Stepping|Special low speed mode to maintain torque
593 -|ex: *5Q8<cr>|Outside limits|{More details coming soon}
594 -|ex: *5Q9<cr>|Stuck|Motor cannot perform request movement at current speed setting
595 -|ex: *5Q10<cr>|Blocked|Similar to stuck, but the motor is at maximum duty and still cannot move (i.e.: stalled)
718 +Ex: #5QG&lt;cr&gt; might return *5QG-1&lt;cr&gt;<div class="wikimodel-emptyline"></div>
596 596  
597 -====== __27. Query Voltage (**QV**)__ ======
720 +The value returned above means the servo is in a counter-clockwise gyration. Sending a #5WR30 command will rotate the servo in a counter-clockwise gyration at 30 RPM.<div class="wikimodel-emptyline"></div>
598 598  
599 -Ex: #5QV<cr> might return *5QV11200<cr>
722 +Configure Gyre (**CG**)<div class="wikimodel-emptyline"></div>
600 600  
601 -The number returned has one decimal, so in the case above, servo with ID 5 has an input voltage of 11.2V (perhaps a three cell LiPo battery).
724 +Ex: #5CG-1&lt;cr&gt;<div class="wikimodel-emptyline"></div>
602 602  
603 -====== __28. Query Temperature (**QT**)__ ======
726 +This changes the gyre direction as described above and also writes to EEPROM.
727 +<div class="wikimodel-emptyline"></div></div></div>
728 +{{/html}}
604 604  
605 -Ex: #5QT<cr> might return *5QT564<cr>
730 +====== __First Position__ ======
606 606  
607 -The units are in tenths of degrees Celcius, so in the example above, the servo's internal temperature is 56.4 degrees C. To convert from degrees Celcius to degrees Farenheit, multiply by 1.8 and add 32. Therefore 56.4C = 133.52F.
732 +{{html wiki="true" clean="false"}}
733 +<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
734 +In certain cases, a user might want to have the servo move to a specific angle upon power up; we refer to this as "first position" (a.k.a. "initial position"). The factory default has no first position value stored in EEPROM and therefore upon power up, the servo remains limp until a position (or hold command) is assigned. Note that the number should be restricted to -1790 (-179.0 degrees) to +1790 (179.0 degrees) and values beyond this will be changed to 1800. <div class="wikimodel-emptyline"></div>
608 608  
609 -====== __29. Query Current (**QC**)__ ======
736 +Query First Position in Degrees (**QFD**)<div class="wikimodel-emptyline"></div>
610 610  
611 -Ex: #5QC<cr> might return *5QC140<cr>
738 +Ex: #5QFD&lt;cr&gt; might return *5QFD900&lt;cr&gt; <div class="wikimodel-emptyline"></div>
612 612  
613 -The units are in milliamps, so in the example above, the servo is consuming 140mA, or 0.14A.
740 +The reply above indicates that servo with ID 5 has a first position of 90.0 degrees. If there is no first position value stored, the reply will be DIS.<div class="wikimodel-emptyline"></div>
614 614  
615 -====== __30. RC Mode (**CRC**)__ ======
742 +Configure First Position in Degrees (**CFD**)<div class="wikimodel-emptyline"></div>
616 616  
617 -This command puts the servo into RC mode (position or continuous), where it will only respond to RC pulses. Note that because this is the case, the servo will no longer accept serial commands. The servo can be placed back into smart mode by using the button menu.
744 +Ex: #5CD900&lt;cr&gt;<div class="wikimodel-emptyline"></div>
618 618  
619 -|**Command sent**|**Note**
620 -|ex: #5CRC<cr>|Stay in smart mode.
621 -|ex: #5CRC1<cr>|Change to RC position mode.
622 -|ex: #5CRC2<cr>|Change to RC continuous (wheel) mode.
623 -|ex: #5CRC*<cr>|Where * is any number or value. Stay in smart mode.
746 +This configuration command means the servo, when set to smart mode, will immediately move to 90.0 degrees upon power up. Sending a CFD command without a number (Ex. #5CFD&lt;cr&gt;) results in the servo remaining limp upon power up. In order to remove the first position, send no value, ex: #5CFD&lt;cr&gt;
747 +<div class="wikimodel-emptyline"></div></div></div>
748 +{{/html}}
624 624  
625 -EX: #5CRC<cr>
750 +====== __Maximum Speed in Degrees (**SD**)__ ======
626 626  
627 -====== __31. RESET__ ======
752 +{{html wiki="true" clean="false"}}
753 +<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
754 +Ex: #5SD1800&lt;cr&gt;<div class="wikimodel-emptyline"></div>
755 +This command sets the servo's maximum speed for motion commands in tenths of degrees per second for that session. In the example above, the servo's maximum speed for that session would be set to 180.0 degrees per second. The servo's maximum speed cannot be set higher than its physical limit at a given voltage. The SD action command overrides CSD (described below) for that session. Upon reset or power cycle, the servo reverts to the value associated with CSD as described below. Note that SD and SR (described below) are effectively the same, but allow the user to specify the speed in either unit. The last command (either SR or SD) received is what the servo uses for that session.<div class="wikimodel-emptyline"></div>
628 628  
629 -Ex: #5RESET<cr> or #5RS<cr>
757 +Query Speed in Degrees (**QSD**)<div class="wikimodel-emptyline"></div>
630 630  
631 -This command does a "soft reset" (no power cycle required) and reverts all commands to those stored in EEPROM (i.e. configuration commands).
759 +Ex: #5QSD&lt;cr&gt; might return *5QSD1800&lt;cr&gt;<div class="wikimodel-emptyline"></div>
632 632  
633 -====== __32. DEFAULT & CONFIRM__ ======
761 +By default QSD will return the current session value, which is set to the value of CSD as reset/power cycle and changed whenever an SD/SR command is processed. If #5QSD1&lt;cr&gt; is sent, the configured maximum speed (CSD value) will be returned instead. You can also query the current speed using "2" and the current target travel speed using "3". See the table below for an example:<div class="wikimodel-emptyline"></div>
634 634  
635 -Ex: #5DEFAULT<cr>
763 +|**Command sent**|**Returned value (1/10 °)**
764 +|ex: #5QSD&lt;cr&gt;|Session value for maximum speed (set by latest SD/SR command)
765 +|ex: #5QSD1&lt;cr&gt;|Configured maximum speed in EEPROM (set by CSD/CSR)
766 +|ex: #5QSD2&lt;cr&gt;|Instantaneous speed (same as QWD)
767 +|ex: #5QSD3&lt;cr&gt;|Target travel speed<div class="wikimodel-emptyline"></div>
636 636  
637 -This command sets in motion the reset all values to the default values included with the version of the firmware installed on that servo. The servo then waits for the CONFIRM command. Any other command received will cause the servo to exit the DEFAULT function.
769 +Configure Speed in Degrees (**CSD**)<div class="wikimodel-emptyline"></div>
638 638  
639 -EX: #5DEFAULT<cr> followed by #5CONFIRM<cr>
771 +Ex: #5CSD1800&lt;cr&gt;<div class="wikimodel-emptyline"></div>
772 +Using the CSD command sets the servo's maximum speed which is saved in EEPROM. In the example above, the servo's maximum speed will be set to 180.0 degrees per second. When the servo is powered on (or after a reset), the CSD value is used. Note that CSD and CSR (described below) are effectively the same, but allow the user to specify the speed in either unit. The last command (either CSR or CSD) is what the servo uses for that session.<div class="wikimodel-emptyline"></div>
773 +</div></div>
774 +{{/html}}
640 640  
641 -Since it it not common to have to restore all configurations, a confirmation command is needed after a firmware command is sent. Should any command other than CONFIRM be received by the servo after the firmware command has been received, it will leave the firmware action.
776 +====== __Maximum Speed in RPM (**SR**)__ ======
642 642  
643 -Note that after the CONFIRM command is sent, the servo will automatically perform a RESET.
778 +{{html wiki="true" clean="false"}}
779 +<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
780 +Ex: #5SR45&lt;cr&gt;<div class="wikimodel-emptyline"></div>
781 +This command sets the servo's maximum speed for motion commands in rpm for that session. In the example above, the servo's maximum speed for that session would be set to 45rpm. The servo's maximum speed cannot be set higher than its physical limit at a given voltage. SR overrides CSR (described below) for that session. Upon reset or power cycle, the servo reverts to the value associated with CSR as described below. Note that SD (described above) and SR are effectively the same, but allow the user to specify the speed in either unit. The last command (either SR or SD) received is what the servo uses for that session.<div class="wikimodel-emptyline"></div>
644 644  
645 -====== __33. UPDATE & CONFIRM__ ======
783 +Query Speed in RPM (**QSR**)<div class="wikimodel-emptyline"></div>
646 646  
647 -Ex: #5UPDATE<cr>
785 +Ex: #5QSR&lt;cr&gt; might return *5QSR45&lt;cr&gt;<div class="wikimodel-emptyline"></div>
648 648  
649 -This command sets in motion the equivalent of a long button press when the servo is not powered in order to enter firmware update mode. This is useful should the button be broken or inaccessible. The servo then waits for the CONFIRM command. Any other command received will cause the servo to exit the UPDATE function.
787 +By default QSR will return the current session value, which is set to the value of CSR as reset/power cycle and changed whenever an SD/SR command is processed. If #5QSR1&lt;cr&gt; is sent, the configured maximum speed (CSR value) will be returned instead. You can also query the current speed using "2" and the current target travel speed using "3". See the table below for an example:<div class="wikimodel-emptyline"></div>
650 650  
651 -EX: #5UPDATE<cr> followed by #5CONFIRM<cr>
789 +|**Command sent**|**Returned value (1/10 °)**
790 +|ex: #5QSR&lt;cr&gt;|Session value for maximum speed (set by latest SD/SR command)
791 +|ex: #5QSR1&lt;cr&gt;|Configured maximum speed in EEPROM (set by CSD/CSR)
792 +|ex: #5QSR2&lt;cr&gt;|Instantaneous speed (same as QWD)
793 +|ex: #5QSR3&lt;cr&gt;|Target travel speed<div class="wikimodel-emptyline"></div>
652 652  
653 -Since it it not common to have to update firmware, a confirmation command is needed after an UPDATE command is sent. Should any command other than CONFIRM be received by the servo after the firmware command has been received, it will leave the firmware action.
795 +Configure Speed in RPM (**CSR**)<div class="wikimodel-emptyline"></div>
654 654  
655 -Note that after the CONFIRM command is sent, the servo will automatically perform a RESET.
797 +Ex: #5CSR45&lt;cr&gt;<div class="wikimodel-emptyline"></div>
798 +Using the CSR command sets the servo's maximum speed which is saved in EEPROM. In the example above, the servo's maximum speed will be set to 45rpm. When the servo is powered on (or after a reset), the CSR value is used. Note that CSD and CSR are effectively the same, but allow the user to specify the speed in either unit. The last command (either CSR or CSD) received is what the servo uses for that session.<div class="wikimodel-emptyline"></div>
799 +</div></div>
800 +{{/html}}
801 +
802 +== Modifiers ==
803 +
804 +====== __Speed (**S**, **SD**) modifier__ ======
805 +
806 +{{html wiki="true" clean="false"}}
807 +<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
808 +Example: #5P1500S750&lt;cr&gt;<div class="wikimodel-emptyline"></div>
809 +Modifier (S) is only for a position (P) action and determines the speed of the move in microseconds per second. A speed of 750 microseconds would cause the servo to rotate from its current position to the desired position at a speed of 750 microseconds per second. This command is in place to ensure backwards compatibility with the SSC-32 / 32U protocol.<div class="wikimodel-emptyline"></div>
810 +Example: #5D0SD180&lt;cr&gt;<div class="wikimodel-emptyline"></div>
811 +Modifier (SD) is only for a position (D) or relative position (MD) action and determines the speed of the move in degrees per second. A speed modifier (SD) of 180 would cause the servo to rotate from its current position to the desired absolute or relative position at a speed of 180 degrees per second.<div class="wikimodel-emptyline"></div>
812 +Query Speed (**QS**)<div class="wikimodel-emptyline"></div>
813 +Example: #5QS&lt;cr&gt; might return *5QS300&lt;cr&gt;<div class="wikimodel-emptyline"></div>
814 +This command queries the current speed in microseconds per second.<div class="wikimodel-emptyline"></div>
815 +</div></div>
816 +{{/html}}
817 +
818 +====== __Timed move (**T**) modifier__ ======
819 +
820 +{{html wiki="true" clean="false"}}
821 +<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
822 +Example: #5P1500T2500&lt;cr&gt;<div class="wikimodel-emptyline"></div>
823 +
824 +Timed move can be used only as a modifier for a position (P, D, MD) actions. The units are in milliseconds, so a timed move of 2500 milliseconds would cause the servo to rotate from its current position to the desired position in 2.5 seconds. The onboard controller will attempt to ensure that the move is performed entirely at the desired velocity, though differences in torque may cause it to not be exact. This command is in place to ensure backwards compatibility with the SSC-32 / 32U protocol.<div class="wikimodel-emptyline"></div>
825 +**Note:** If the calculated speed at which a servo must rotate for a timed move is greater than its maximum speed (which depends on voltage and load), then it will move at its maximum speed, and the time of the move may be longer than requested.<div class="wikimodel-emptyline"></div>
826 +</div></div>
827 +{{/html}}
828 +
829 +====== __Current Halt & Hold (**CH**) modifier__ ======
830 +
831 +{{html wiki="true" clean="false"}}
832 +<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
833 +Example: #5D1423CH400&lt;cr&gt;<div class="wikimodel-emptyline"></div>
834 +
835 +This has servo with ID 5 move to 142.3 degrees but, should it detect a current of 400mA or higher before it reaches the desired position, will immediately halt and hold position.<div class="wikimodel-emptyline"></div>
836 +This modifier can be added to the following actions: D; MD; WD; WR.<div class="wikimodel-emptyline"></div>
837 +</div></div>
838 +{{/html}}
839 +
840 +====== __Current Limp (**CL**) modifier__ ======
841 +
842 +{{html wiki="true" clean="false"}}
843 +<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
844 +Example: #5D1423CL400&lt;cr&gt;<div class="wikimodel-emptyline"></div>
845 +
846 +This has servo with ID 5 move to 142.3 degrees but, should it detect a current of 400mA or higher before it reaches the desired position, will immediately go limp.<div class="wikimodel-emptyline"></div>
847 +This modifier can be added to the following actions: D; MD; WD; WR.<div class="wikimodel-emptyline"></div>
848 +</div></div>
849 +{{/html}}
850 +
851 +== Telemetry ==
852 +
853 +====== __Query Voltage (**QV**)__ ======
854 +
855 +{{html wiki="true" clean="false"}}
856 +<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
857 +Ex: #5QV&lt;cr&gt; might return *5QV11200&lt;cr&gt;<div class="wikimodel-emptyline"></div>
858 +The number returned is in milliVolts, so in the case above, servo with ID 5 has an input voltage of 11.2V.<div class="wikimodel-emptyline"></div>
859 +</div></div>
860 +{{/html}}
861 +
862 +====== __Query Temperature (**QT**)__ ======
863 +
864 +{{html wiki="true" clean="false"}}
865 +<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
866 +Ex: #5QT&lt;cr&gt; might return *5QT564&lt;cr&gt;<div class="wikimodel-emptyline"></div>
867 +The units are in tenths of degrees Celcius, so in the example above, the servo's internal temperature is 56.4 degrees C. To convert from degrees Celcius to degrees Farenheit, multiply by 1.8 and add 32. Therefore 56.4C = 133.52F.<div class="wikimodel-emptyline"></div>
868 +</div></div>
869 +{{/html}}
870 +
871 +====== __Query Current (**QC**)__ ======
872 +
873 +{{html wiki="true" clean="false"}}
874 +<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
875 +Ex: #5QC&lt;cr&gt; might return *5QC140&lt;cr&gt;<div class="wikimodel-emptyline"></div>
876 +The units are in milliamps, so in the example above, the servo is consuming 140mA, or 0.14A.<div class="wikimodel-emptyline"></div>
877 +</div></div>
878 +{{/html}}
879 +
880 +====== __Query Model String (**QMS**)__ ======
881 +
882 +{{html wiki="true" clean="false"}}
883 +<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
884 +Ex: #5QMS&lt;cr&gt; might return *5QMSLSS-HS1&lt;cr&gt;<div class="wikimodel-emptyline"></div>
885 +This reply means that the servo model is LSS-HS1: a high speed servo, first revision.<div class="wikimodel-emptyline"></div>
886 +</div></div>
887 +{{/html}}
888 +
889 +====== __Query Firmware (**QF**)__ ======
890 +
891 +{{html wiki="true" clean="false"}}
892 +<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
893 +Ex: #5QF&lt;cr&gt; might return *5QF368&lt;cr&gt;<div class="wikimodel-emptyline"></div>
894 +The number in the reply represents the firmware version, in this example being 368.<div class="wikimodel-emptyline"></div>
895 +The command #5QF3&lt;cr&gt; can also be sent and the servo will reply with a 3 numbers firmware version, for example, 368.29.14<div class="wikimodel-emptyline"></div>
896 +</div></div>
897 +{{/html}}
898 +
899 +====== __Query Serial Number (**QN**)__ ======
900 +
901 +{{html wiki="true" clean="false"}}
902 +<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
903 +Ex: #5QN&lt;cr&gt; might return *5QN12345678&lt;cr&gt;<div class="wikimodel-emptyline"></div>
904 +The number in the response (12345678) would be the servo's serial number which is set and should not be changed by the user.<div class="wikimodel-emptyline"></div>
905 +</div></div>
906 +{{/html}}
907 +
908 +== RGB LED ==
909 +
910 +====== __LED Color (**LED**)__ ======
911 +
912 +{{html wiki="true" clean="false"}}
913 +<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
914 +Ex: #5LED3&lt;cr&gt;<div class="wikimodel-emptyline"></div>
915 +This action sets the servo's RGB LED color for that session.The LED can be used for aesthetics, or (based on user code) to provide visual status updates. Using timing can create patterns.<div class="wikimodel-emptyline"></div>
916 +0=Off (black); 1=Red 2=Green; 3=Blue; 4=Yellow; 5=Cyan; 6=Magenta; 7=White;<div class="wikimodel-emptyline"></div>
917 +Query LED Color (**QLED**)<div class="wikimodel-emptyline"></div>
918 +Ex: #5QLED&lt;cr&gt; might return *5QLED5&lt;cr&gt;<div class="wikimodel-emptyline"></div>
919 +This simple query returns the indicated servo's LED color.<div class="wikimodel-emptyline"></div>
920 +Configure LED Color (**CLED**)<div class="wikimodel-emptyline"></div>
921 +Ex: #5CLED3&lt;cr&gt;<div class="wikimodel-emptyline"></div>
922 +Configuring the LED color via the CLED command sets the startup color of the servo after a reset or power cycle. Note that it also changes the session's LED color immediately as well. The command above will configure the servo's LED to a Blue color.<div class="wikimodel-emptyline"></div>
923 +</div></div>
924 +{{/html}}
925 +
926 +====== __Configure LED Blinking (**CLB**)__ ======
927 +
928 +{{html wiki="true" clean="false"}}
929 +<div class="cmdcnt"><div class="cmdpad"></div><div class="cmdtxt">
930 +This command allows you to control when the RGB LED will blink the user set color (see RGB LED command for details). This is very useful when visually seeing what the servo is doing. You can turn on or off blinking for various LSS status. The command requires that the servo be RESET. Here is the list and their associated value:<div class="wikimodel-emptyline"></div>
931 +
932 +(% style="width:195px" %)
933 +|(% style="width:134px" %)**Blink While:**|(% style="width:58px" %)**#**
934 +|(% style="width:134px" %)No blinking|(% style="width:58px" %)0
935 +|(% style="width:134px" %)Limp|(% style="width:58px" %)1
936 +|(% style="width:134px" %)Holding|(% style="width:58px" %)2
937 +|(% style="width:134px" %)Accelerating|(% style="width:58px" %)4
938 +|(% style="width:134px" %)Decelerating|(% style="width:58px" %)8
939 +|(% style="width:134px" %)Free|(% style="width:58px" %)16
940 +|(% style="width:134px" %)Travelling|(% style="width:58px" %)32
941 +|(% style="width:134px" %)Always blink|(% style="width:58px" %)63<div class="wikimodel-emptyline"></div>
942 +
943 +To set blinking, use CLB with the value of your choosing. To activate blinking in multiple status, simply add together the values of the corresponding status. See examples below:<div class="wikimodel-emptyline"></div>
944 +Ex: #5CLB0<cr> to turn off all blinking (LED always solid)<div class="wikimodel-emptyline"></div>
945 +Ex: #5CLB1<cr> only blink when limp (1)<div class="wikimodel-emptyline"></div>
946 +Ex: #5CLB2<cr> only blink when holding (2)<div class="wikimodel-emptyline"></div>
947 +Ex: #5CLB12<cr> only blink when accel or decel (accel 4 + decel 8 = 12)<div class="wikimodel-emptyline"></div>
948 +Ex: #5CLB48<cr> only blink when free or travel (free 16 + travel 32 = 48)<div class="wikimodel-emptyline"></div>
949 +Ex: #5CLB63<cr> blink in all status (1 + 2 + 4 + 8 + 16 + 32)<div class="wikimodel-emptyline"></div>
950 +RESETTING the servo is needed.<div class="wikimodel-emptyline"></div>
951 +</div></div>
952 +{{/html}}
953 +
954 += RGB LED Patterns =
955 +
956 +The LED patterns below do not include those which are part of the button menu, which can be found here: [[LSS Button Menu>>doc:lynxmotion-smart-servo.lss-button-menu.WebHome]]
957 +
958 +[[image:LSS - LED Patterns.png]]
LSS - LED Patterns.png
Author
... ... @@ -1,0 +1,1 @@
1 +xwiki:XWiki.RB1
Size
... ... @@ -1,0 +1,1 @@
1 +116.3 KB
Content
XWiki.XWikiRights[0]
Allow/Deny
... ... @@ -1,1 +1,0 @@
1 -1
Groups
... ... @@ -1,1 +1,0 @@
1 -xwiki:XWiki.XWikiAdminGroup
Levels
... ... @@ -1,1 +1,0 @@
1 -view
XWiki.XWikiRights[1]
Allow/Deny
... ... @@ -1,1 +1,0 @@
1 -1
Groups
... ... @@ -1,1 +1,0 @@
1 -XWiki.XWikiAdminGroup
Levels
... ... @@ -1,1 +1,0 @@
1 -view
XWiki.XWikiRights[2]
Allow/Deny
... ... @@ -1,1 +1,0 @@
1 -1
Groups
... ... @@ -1,1 +1,0 @@
1 -XWiki.Profiles (Lynxmotion).BETA Testers
Levels
... ... @@ -1,1 +1,0 @@
1 -view
Copyright RobotShop 2018